Reduced Field-of-View Diffusion Imaging of the Human Spinal Cord: Comparison with Conventional Single-Shot Echo-Planar Imaging

被引:87
|
作者
Zaharchuk, G. [1 ]
Saritas, E. U. [2 ]
Andre, J. B.
Chin, C. T. [3 ]
Rosenberg, J.
Brosnan, T. J.
Shankaranarayan, A. [4 ]
Nishimura, D. G. [2 ]
Fischbein, N. J.
机构
[1] Stanford Univ, Med Ctr, Dept Radiol, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
[3] Univ Calif San Francisco, Dept Radiol, San Francisco, CA USA
[4] GE Healthcare, Appl Sci Lab W, Menlo Pk, CA USA
关键词
WEIGHTED MRI; MULTIPLE-SCLEROSIS; IN-VIVO; CERVICAL CORD; OPTIC-NERVE; TENSOR MRI; RESOLUTION; INFARCTION; EPI; TRACTOGRAPHY;
D O I
10.3174/ajnr.A2418
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: DWI of the spinal cord is challenging because of its small size and artifacts associated with the most commonly used clinical imaging method, SS-EPI. We evaluated the performance of rFOV spinal cord DWI and compared it with the routine fF0V SS-EPI in a clinical population. MATERIALS AND METHODS: Thirty-six clinical patients underwent 1.5T MR imaging examination that included rFOV SS-EPI DWI of the cervical spinal cord as well as 2 comparison diffusion sequences: fF0V SS-EPI DWI normalized for either image readout time (low-resolution fF0V) or spatial resolution (high-resolution fF0V). ADC maps were created and compared between the methods by using single-factor analysis of variance. Two neuroradiologists blinded to sequence type rated the 3 DWI methods, based on susceptibility artifacts, perceived spatial resolution, signal intensity-to-noise ratio, anatomic detail, and clinical utility. RESULTS: ADC values for the rFOV and both fF0V sequences were not statistically different (rFOV: 1.01 +/- 0.18 x 10(-3) mm(2)/s; low-resolution fFOV: 1.12 +/- 0.22 X 10(-3) mm(2)/s; high-resolution fFOV: 1.10 +/- 0.21 x 10(-3) mm(2)/s; F = 2.747, P > .05). The neuroradiologist reviewers rated the rFOV diffusion images superior in terms of all assessed measures (P < 0.0001). Particular improvements were noted in patients with metal hardware, degenerative disease, or both. CONCLUSIONS: rFOV DWI of the spinal cord overcomes many of the problems associated with conventional fF0V SS-EPI and is feasible in a clinical population. From a clinical standpoint, images were deemed superior to those created by using standard fF0V methods.
引用
收藏
页码:813 / 820
页数:8
相关论文
共 50 条
  • [41] Reduced field-of-view diffusion-weighted imaging of the brain at 7 T
    von Morze, Cornelius
    Kelley, Douglas A. C.
    Shepherd, Timothy M.
    Banerjee, Suchandrima
    Xu, Duan
    Hess, Christopher P.
    MAGNETIC RESONANCE IMAGING, 2010, 28 (10) : 1541 - 1545
  • [42] Improving the performance of diffusion-weighted inner field-of-view echo-planar imaging based on 2D-Selective radiofrequency excitations by tilting the excitation plane
    Finsterbusch, Juergen
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 35 (04) : 984 - 992
  • [43] A tractography comparison between turboprop and spin-echo echo-planar diffusion tensor imaging
    Gui, Minzhi
    Peng, Huiling
    Carew, John D.
    Lesniak, Maciej S.
    Arfanakis, Konstantinos
    NEUROIMAGE, 2008, 42 (04) : 1451 - 1462
  • [44] Study of the Reduced Field-of-View Diffusion-Weighted Imaging of the Breast
    Dong, Haibo
    Li, Yadi
    Li, Hui
    Wang, Bo
    Hu, Bin
    CLINICAL BREAST CANCER, 2014, 14 (04) : 265 - 271
  • [45] Reduced Field-of-View Diffusion Tensor Imaging of the Spinal Cord Shows Motor Dysfunction of the Lower Extremities in Patients With Cervical Compression Myelopathy
    Maki, Satoshi
    Koda, Masao
    Ota, Mitsutoshi
    Oikawa, Yoshihiro
    Kamiya, Koshiro
    Inada, Taigo
    Furuya, Takeo
    Takahashi, Kazuhisa
    Masuda, Yoshitada
    Matsumoto, Koji
    Kojima, Masatoshi
    Obata, Takayuki
    Yamazaki, Masashi
    SPINE, 2018, 43 (02) : 89 - 96
  • [46] Quantitative diffusion MRI using reduced field-of-view and multi-shot acquisition techniques: Validation in phantoms and prostate imaging
    Zhang, Yuxin
    Holmes, James
    Rabanillo, Inaki
    Guidon, Arnaud
    Wells, Shane
    Hernando, Diego
    MAGNETIC RESONANCE IMAGING, 2018, 51 : 173 - 181
  • [47] Flexible reduced field of view magnetic resonance imaging based on single-shot spatiotemporally encoded technique
    Li Jing
    Cai Cong-Bo
    Chen Lin
    Chen Ying
    Qu Xiao-Bo
    Cai Shu-Hui
    CHINESE PHYSICS B, 2015, 24 (10)
  • [48] Considerations in high-resolution skeletal muscle diffusion tensor imaging using single-shot echo planar imaging with stimulated-echo preparation and sensitivity encoding
    Karampinos, Dimitrios C.
    Banerjee, Suchandrima
    King, Kevin F.
    Link, Thomas M.
    Majumdar, Sharmila
    NMR IN BIOMEDICINE, 2012, 25 (05) : 766 - 778
  • [49] Two-Dimensional Single-Shot Diffusion-Weighted Stimulated EPI With Reduced FOV for Ultrahigh-b Radial Diffusion-Weighted Imaging of Spinal Cord
    Sapkota, Nabraj
    Shi, Xianfeng
    Shah, Lubdha M.
    Bisson, Erica F.
    Rose, John W.
    Jeong, Eun-Kee
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (06) : 2167 - 2173
  • [50] Turbo Spin-echo Diffusion-weighted Imaging Compared with Single-shot Echo-planar Diffusion-weighted Imaging: Image Quality and Diagnostic Performance When Differentiating between Ductal Carcinoma in situ and Invasive Ductal Carcinoma
    Mori, Naoko
    Mugikura, Shunji
    Miyashita, Minoru
    Mori, Yu
    Maekawa, Yui
    Nagasaka, Tatsuo
    Takase, Kei
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2021, 20 (01) : 60 - 68