Reduced Field-of-View Diffusion Imaging of the Human Spinal Cord: Comparison with Conventional Single-Shot Echo-Planar Imaging

被引:87
|
作者
Zaharchuk, G. [1 ]
Saritas, E. U. [2 ]
Andre, J. B.
Chin, C. T. [3 ]
Rosenberg, J.
Brosnan, T. J.
Shankaranarayan, A. [4 ]
Nishimura, D. G. [2 ]
Fischbein, N. J.
机构
[1] Stanford Univ, Med Ctr, Dept Radiol, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
[3] Univ Calif San Francisco, Dept Radiol, San Francisco, CA USA
[4] GE Healthcare, Appl Sci Lab W, Menlo Pk, CA USA
关键词
WEIGHTED MRI; MULTIPLE-SCLEROSIS; IN-VIVO; CERVICAL CORD; OPTIC-NERVE; TENSOR MRI; RESOLUTION; INFARCTION; EPI; TRACTOGRAPHY;
D O I
10.3174/ajnr.A2418
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: DWI of the spinal cord is challenging because of its small size and artifacts associated with the most commonly used clinical imaging method, SS-EPI. We evaluated the performance of rFOV spinal cord DWI and compared it with the routine fF0V SS-EPI in a clinical population. MATERIALS AND METHODS: Thirty-six clinical patients underwent 1.5T MR imaging examination that included rFOV SS-EPI DWI of the cervical spinal cord as well as 2 comparison diffusion sequences: fF0V SS-EPI DWI normalized for either image readout time (low-resolution fF0V) or spatial resolution (high-resolution fF0V). ADC maps were created and compared between the methods by using single-factor analysis of variance. Two neuroradiologists blinded to sequence type rated the 3 DWI methods, based on susceptibility artifacts, perceived spatial resolution, signal intensity-to-noise ratio, anatomic detail, and clinical utility. RESULTS: ADC values for the rFOV and both fF0V sequences were not statistically different (rFOV: 1.01 +/- 0.18 x 10(-3) mm(2)/s; low-resolution fFOV: 1.12 +/- 0.22 X 10(-3) mm(2)/s; high-resolution fFOV: 1.10 +/- 0.21 x 10(-3) mm(2)/s; F = 2.747, P > .05). The neuroradiologist reviewers rated the rFOV diffusion images superior in terms of all assessed measures (P < 0.0001). Particular improvements were noted in patients with metal hardware, degenerative disease, or both. CONCLUSIONS: rFOV DWI of the spinal cord overcomes many of the problems associated with conventional fF0V SS-EPI and is feasible in a clinical population. From a clinical standpoint, images were deemed superior to those created by using standard fF0V methods.
引用
收藏
页码:813 / 820
页数:8
相关论文
共 50 条
  • [1] Reduced Field-of-View Diffusion-Weighted Magnetic Resonance Imaging of the Pancreas: Comparison with Conventional Single-Shot Echo-Planar Imaging
    Kim, Hyungjin
    Lee, Jeong Min
    Yoon, Jeong Hee
    Jang, Jin-Young
    Kim, Sun-Whe
    Ryu, Ji Kon
    Kannengiesser, Stephan
    Ha, Joon Koo
    Choi, Byung Ihn
    KOREAN JOURNAL OF RADIOLOGY, 2015, 16 (06) : 1216 - 1225
  • [2] Diffusion tensor imaging focusing on lower cervical spinal cord using 2D reduced FOV interleaved multislice single-shot diffusion-weighted echo-planar imaging: comparison with conventional single-shot diffusion-weighted echo-planar imaging
    Park, Eun Hae
    Lee, Young Han
    Jeong, Eun-Kee
    Roh, Yun Ho
    Suh, Jin-Suck
    MAGNETIC RESONANCE IMAGING, 2015, 33 (04) : 401 - 406
  • [3] Reduced field of view echo-planar imaging diffusion tensor MRI for pediatric spinal tumors
    Kim, Lily H.
    Lee, Edward H.
    Galvez, Michelle
    Aksoy, Murat
    Skare, Stefan
    O'Halloran, Rafael
    Edwards, Michael S. B.
    Holdsworth, Samantha J.
    Yeom, Kristen W.
    JOURNAL OF NEUROSURGERY-SPINE, 2019, 31 (04) : 607 - 615
  • [4] Diffusion Tensor Imaging of the Brachial Plexus: A Comparison between Readout-segmented and Conventional Single-shot Echo-planar Imaging
    Ho, Michael J.
    Ciritsis, Alexander
    Manoliu, Andrei
    Stieltjes, Bram
    Marcon, Magda
    Andreisek, Gustav
    Kuhn, Felix Pierre
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2019, 18 (02) : 150 - 157
  • [5] Readout-segmented echo-planar imaging in diffusion-weighted MR imaging of acute infarction of the brainstem and posterior fossa: comparison of single-shot echo-planar diffusion-weighted sequences
    Byeon, Jonghyun
    Kim, Jee Young
    Cho, A-Hyun
    CLINICAL IMAGING, 2015, 39 (05) : 765 - 769
  • [6] Comparison of multiplexed sensitivity encoding and single-shot echo-planar imaging for diffusion-weighted imaging of the liver
    Kim, Yeun-Yoon
    Kim, Myeong-Jin
    Gho, Sung-Min
    Seo, Nieun
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 132
  • [7] Readout-Segmented Echo-Planar Imaging in Diffusion-Weighted MR Imaging in Breast Cancer: Comparison with Single-Shot Echo-Planar Imaging in Image Quality
    Kim, Yun Ju
    Kim, Sung Hun
    Kang, Bong Joo
    Park, Chang Suk
    Kim, Hyeon Sook
    Son, Yo Han
    Porter, David Andrew
    Song, Byung Joo
    KOREAN JOURNAL OF RADIOLOGY, 2014, 15 (04) : 403 - 410
  • [8] Performance of Single-Shot Echo-Planar Imaging in Diffusion Tensor Imaging in Rat Sciatic Nerve Compared With Readout-Segmented Echo-Planar Imaging
    Chen, Yueyao
    Pan, Zhongxian
    Meng, Fanqi
    Li, Zhujing
    Hu, Yuanming
    Yu, Xuewen
    Gao, Jinyun
    Guo, Yihao
    Lyu, Hanqing
    Lin, Xiaofeng
    FRONTIERS IN NEUROSCIENCE, 2022, 16
  • [9] Detection of Middle Ear Cholesteatoma by Diffusion-Weighted MR Imaging: Multishot Echo-Planar Imaging Compared with Single-Shot Echo-Planar Imaging
    Yamashita, K.
    Yoshiura, T.
    Hiwatashi, A.
    Kamano, H.
    Dashjamts, T.
    Shibata, S.
    Tamae, A.
    Honda, H.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (10) : 1915 - 1918
  • [10] Quantitative Susceptibility Mapping Using Single-Shot Echo-Planar Imaging
    Sun, Hongfu
    Wilman, Alan H.
    MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (05) : 1932 - 1938