Long-term follow-up of all-polyethylene tibial components when used for oncological endoprosthetic reconstruction A SINGLE-INSTITUTION EXPERIENCE

被引:6
|
作者
Bernthal, N. M. [1 ]
Burke, Z. D. C. [1 ]
Hegde, V [1 ]
Upfill-Brown, A. [1 ]
Chen, C. J. [1 ]
Hwang, R. [1 ]
Eckardt, J. J. [1 ]
机构
[1] Univ Calif Los Angeles, David Geffen Sch Med, Dept Orthoped Surg, Univ Calif Santa Monica, Santa Monica, CA 90403 USA
基金
美国国家卫生研究院;
关键词
TOTAL KNEE ARTHROPLASTY; TUMOR ENDOPROSTHESES; FIXATION; OUTCOMES; STEMS;
D O I
10.1302/0301-620X.102B2.BJJ-2019-0535.R1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Aims We aimed to examine the long-term mechanical survivorship, describe the modes of all-cause failure, and identify risk factors for mechanical failure of all-polyethylene tibial components in endoprosthetic reconstruction. Methods This is a retrospective database review of consecutive endoprosthetic reconstructions performed for oncological indications between 1980 and 2019. Patients with allpolyethylene tibial components were isolated and analyzed for revision for mechanical failure. Outcomes included survival of the all-polyethylene tibial component, revision surgery categorized according to the Henderson Failure Mode Classification, and complications and functional outcome, as assessed by the Musculoskeletal Tumor Society (MSTS) score at the final follow-up. Results A total of 278 patients were identified with 289 all-polyethylene tibial components. Mechanical survival was 98.4%, 91.1%, and 85.2% at five, ten and 15 years, respectively. A total of 15 mechanical failures were identified at the final follow-up. Of the 13 allpolyethylene tibial components used for revision of a previous tibial component, five (38.5%) failed mechanically. Younger patients (< 18 years vs > 18 years; p = 0.005) and those used as revision components (p < 0.001) had significantly increased rates of failure. Multivariate logistic regression modelling showed revision status to be a positive risk factor for failure (odds ratio (OR) 19.498, 95% confidence interval (CI) 4.598 to 82.676) and increasing age was a negative risk factor for failure (OR 0.927, 95% CI 0.872 to 0.987). Agestratified risk analysis showed that age > 24 years was no longer a statistically significant risk factor for failure. The final mean MSTS score for all patients was 89% (8.5% to 100.0%). Conclusion The long-term mechanical survivorship of all-polyethylene tibial components when used for tumour endoprostheses was excellent. Tumour surgeons should consider using these components for their durability and the secondary benefits of reduced cost and ease of removal and revision. However, caution should be taken when using all-polyethylene tibial components in the revision setting as a significantly higher rate of mechanical failure was seen in this group of patients.
引用
收藏
页码:170 / 176
页数:7
相关论文
共 36 条
  • [1] Good survivorship of all-polyethylene tibial component UKA at long-term follow-up
    Bruni, Danilo
    Gagliardi, Michele
    Akkawi, Ibrahim
    Raspugli, Giovanni Francesco
    Bignozzi, Simone
    Marko, Tedi
    Bragonzoni, Laura
    Grassi, Alberto
    Marcacci, Maurilio
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2016, 24 (01) : 182 - 187
  • [2] All-Polyethylene Tibial Components: An Analysis of Long-Term Outcomes and Infection
    Houdek, Matthew T.
    Wagner, Eric R.
    Wyles, Cody C.
    Watts, Chad D.
    Cass, Joseph R.
    Trousdale, Robert T.
    JOURNAL OF ARTHROPLASTY, 2016, 31 (07) : 1476 - 1482
  • [3] Need for long-term follow-up in sinonasal inverted papilloma: A Single-institution experience
    Binz, Gregori H. A.
    Soyka, Michael B.
    Holzmann, David
    Meerwein, Christian M.
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2021, 43 (02): : 630 - 638
  • [4] All-polyethylene tibial components in TKA in rheumatoid arthritis: a 25-year follow-up study
    Nouta, Klaas-Auke
    Pijls, Bart G.
    Nelissen, Rob G. H. H.
    INTERNATIONAL ORTHOPAEDICS, 2012, 36 (03) : 565 - 570
  • [5] All-polyethylene tibial components in TKA in rheumatoid arthritis: a 25-year follow-up study
    Klaas-Auke Nouta
    Bart G. Pijls
    Rob G. H. H. Nelissen
    International Orthopaedics, 2012, 36 : 565 - 570
  • [6] Surgical management of medium and large petroclival meningiomas: a single institution's experience of 199 cases with long-term follow-up
    Li, Da
    Tang, Jie
    Ren, Cong
    Wu, Zhen
    Zhang, Li-Wei
    Zhang, Jun-Ting
    ACTA NEUROCHIRURGICA, 2016, 158 (03) : 409 - 425
  • [7] Long-term follow-up of living liver donors: A single-center experience
    Abdel-Khalek, Ehab E.
    Abdel-Wahab, Mohamed
    Elgazzar, Mohamed H.
    Khattab, Mahmoud A.
    El-Gilany, Abdel-Hady
    Elgouhari, Hesham M.
    Shehta, Ahmed
    LIVER TRANSPLANTATION, 2022, 28 (09) : 1490 - 1499
  • [8] Abdominal Wall Reconstruction with Retrorectus Self-Adhering Mesh: A Single-Center Long-Term Follow-Up
    Bashian, Elizabeth
    Daoud, Georges
    Khansa, Ibrahim
    Janis, Jeffrey E.
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2023, 151 (03) : 646 - 650
  • [9] Long-term follow-up of microscopic polyangiitis, 17-year experience at a single center
    Borao-Cengotita-Bengoa, Maria
    Corral-Gudino, Luis
    del Pino-Montes, Javier
    Lerma-Marquez, Jose Luis
    EUROPEAN JOURNAL OF INTERNAL MEDICINE, 2010, 21 (06) : 542 - 547
  • [10] Synchronous/Metachronous Bilateral Breast Cancer: a Long-Term Follow-up Single-Center Experience
    Mermut, Ozlem
    Yalcin, Berrin
    Gursu, Riza Umar
    Trabulus, Didem Can
    Dal, Fatih
    Talu, Esra Canan Kelten
    Arslan, Esra
    Ata, Emine Sevcan
    INDIAN JOURNAL OF SURGERY, 2024, 86 (04) : 760 - 767