Absolute quantification of myocardial blood flow with 13N-ammonia and 3-dimensional PET

被引:41
作者
Schepis, Tiziano [1 ]
Gaemperli, Oliver [1 ]
Treyer, Valerie [1 ]
Valenta, Ines [1 ]
Burger, Cyrill [1 ]
Koepfli, Pascal [1 ]
Namdar, Mehdi [1 ]
Adachi, Itaru [4 ]
Alkadhi, Hatem [2 ]
Kaufmann, Philipp A. [1 ,3 ]
机构
[1] Univ Zurich Hosp, Ctr Cardiovasc, Clin Nucl Med, CH-8091 Zurich, Switzerland
[2] Univ Zurich Hosp, Inst Diagnos Radiol, CH-8091 Zurich, Switzerland
[3] Univ Zurich, Ctr Integrat Human Physiol, CH-8091 Zurich, Switzerland
[4] Osaka Med Coll, Dept Radiol, Takatsuki, Osaka 569, Japan
关键词
myocardial blood flow; 3-dimensional PET; N-13-NH3; image reconstruction algorithms;
D O I
10.2967/jnumed.107.044099
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to compare 2-dimensional (2D) and 3-dimensional (3D) dynamic PET for the absolute quantification of myocardial blood flow (MBF) with N-13-ammonia (N-13-NH3)Methods: 2D and 3D MBF measurements were collected from 21 patients undergoing cardiac evaluation at rest (n = 14) and during standard adenosine stress (n = 7). A lutetium yttrium oxyorthosilicate-based PET/CT system with retractable septa, enabling the sequential acquisition of 2D and 3D images within the same patient and study, was used. All 2D studies were performed by injecting 700-900 MBq of N-13-NH3. For 14 patients, 3D studies were performed with the same injected N-13-NH3 dose as that used in 2D studies. For the remaining 7 patients, 3D images were acquired with a lower dose of N-13-NH3, that is, 500 MBq. 2D images reconstructed by use of filtered back-projection (FBP) provided the reference standard for MBF measurements. 3D images were reconstructed by use of Fourier rebinning (FORE) with FBP (FORE-FBP), FORE with ordered-subsets expectation maximization (FORE-OSEM), and a reprojection algorithm (RP). Results: Global MBF measurements derived from 3D PET with FORE-FBP (r = 0.97), FORE-OSEM (r = 0.97), and RP (r = 0.97) were well correlated with those derived from 2D FBP (all Ps < 0.0001). The mean +/- SD differences in global MBF measurements between 3D FORE-FBP and 2D FBP and between 3D FORE-OSEM and 2D FBP were 0.01 +/- 0.14 and 0.01 +/- 0.15 mL/min/g, respectively. The mean +/- SD difference in global MBF measurements between 3D RP and 2D FBP was 0.00 +/- 0.16 mL/min/g. The best correlation between 2D PET and 3D PET performed with the lower injected activity was found for the 3D FORE-FBP reconstruction algorithm (r = 0.95,P< 0.001). Conclusion: For this scanner type, quantitative measurements of MBF with 3D PET and N-13-NH3 were in excellent agreement with those obtained with the 2D technique, even when a lower activity was injected.
引用
收藏
页码:1783 / 1789
页数:7
相关论文
共 50 条
  • [41] First Validation of Myocardial Flow Reserve Derived from Dynamic 99mTc-Sestamibi CZT-SPECT Camera Compared with 13N-Ammonia PET A Pilot Study
    Yamamoto, Atsushi
    Nagao, Michinobu
    Ando, Kiyoe
    Nakao, Risako
    Matsuo, Yuka
    Sakai, Akiko
    Momose, Mitsuru
    Kaneko, Koichiro
    Hagiwara, Nobuhisa
    Sakai, Shuji
    [J]. INTERNATIONAL HEART JOURNAL, 2022, 63 (02) : 202 - 209
  • [42] Vessel-specific quantification of absolute myocardial blood flow, myocardial flow reserve and relative flow reserve by means of fused dynamic 13NH3 PET and CCTA: Ranges in a low-risk population and abnormality criteria
    Marina Piccinelli
    Sang-Geon Cho
    Ernest V. Garcia
    Erick Alexanderson
    Joo Myung Lee
    C. David Cooke
    Nikhil Goyal
    Mauricio Santos Sanchez
    Russel D. Folks
    Zhengjia Chen
    John Votaw
    Bon-Kwon Koo
    Hee-Seung Bom
    [J]. Journal of Nuclear Cardiology, 2020, 27 : 1756 - 1769
  • [43] Vessel-specific quantification of absolute myocardial blood flow, myocardial flow reserve and relative flow reserve by means of fused dynamic 13NH3 PET and CCTA: Ranges in a low-risk population and abnormality criteria
    Piccinelli, Marina
    Cho, Sang-Geon
    Garcia, Ernest V.
    Alexanderson, Erick
    Lee, Joo Myung
    Cooke, C. David
    Goyal, Nikhil
    Sanchez, Mauricio Santos
    Folks, Russel D.
    Chen, Zhengjia
    Votaw, John
    Koo, Bon-Kwon
    Bom, Hee-Seung
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2020, 27 (05) : 1756 - 1769
  • [44] DIRECT COMPARISON OF [N-13] AMMONIA AND [O-15]WATER ESTIMATES OF PERFUSION WITH QUANTIFICATION OF REGIONAL MYOCARDIAL BLOOD-FLOW BY MICROSPHERES
    BOL, A
    MELIN, JA
    VANOVERSCHELDE, JL
    BAUDHUIN, T
    VOGELAERS, D
    DEPAUW, M
    MICHEL, C
    LUXEN, A
    LABAR, D
    COGNEAU, M
    ROBERT, A
    HEYNDRICKX, GR
    WIJNS, W
    [J]. CIRCULATION, 1993, 87 (02) : 512 - 525
  • [45] Myocardial Blood Flow and Flow Reserve in Proximal and Mid-to-Distal Lesions of Left Anterior Descending Artery Measured By N-13 Ammonia PET/CT
    Cho S.-G.
    Kim J.H.
    Cho J.Y.
    Kim H.S.
    Bom H.-S.
    [J]. Nuclear Medicine and Molecular Imaging, 2013, 47 (3) : 158 - 165
  • [46] Fast, heart-rate independent, whole-heart, free-breathing, three-dimensional myocardial BOLD MRI at 3T with simultaneous 13N-ammonia PET validation in canines
    Yang H.-J.
    Dey D.
    Sykes J.M.
    Butler J.
    Sharif B.
    Li D.
    Tsaftaris S.
    Bi X.
    Slomka P.
    Prato F.S.
    Dharmakumar R.
    [J]. Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [47] Towards reliable myocardial blood-oxygen-level-dependent (BOLD) CMR using late effects of regadenoson with simultaneous 13n-ammonia pet validation in a whole-body hybrid PET/MR system
    Hsin-Jung Yang
    Damini Dey
    Jane M Sykes
    John Butler
    Behzad Sharif
    Debiao Li
    Sotirios Tsaftaris
    Piotr Slomka
    Frank S Prato
    Rohan Dharmakumar
    [J]. Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [48] Validation of myocardial blood flow estimation with nitrogen-13 ammonia PET by the argon inert gas technique in humans
    Kotzerke, J
    Glatting, G
    van den Hoff, J
    Höher, M
    Neumaier, B
    Wöhrle, J
    Reske, SN
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (03) : 340 - 345
  • [49] Simultaneous 13N-Ammonia and gadolinium first-pass myocardial perfusion with quantitative hybrid PET-MR imaging: a phantom and clinical feasibility study
    Muhummad Sohaib Nazir
    Sarah-May Gould
    Xenios Milidonis
    Eliana Reyes
    Tevfik F. Ismail
    Radhouene Neji
    Sébastien Roujol
    Jim O’Doherty
    Hui Xue
    Sally F. Barrington
    Tobias Schaeffter
    Reza Razavi
    Paul Marsden
    Peter Kellman
    Sven Plein
    Amedeo Chiribiri
    [J]. European Journal of Hybrid Imaging, 3
  • [50] Simultaneous 13N-Ammonia and gadolinium first-pass myocardial perfusion with quantitative hybrid PET-MR imaging: a phantom and clinical feasibility study
    Nazir, Muhummad Sohaib
    Gould, Sarah-May
    Milidonis, Xenios
    Reyes, Eliana
    Ismail, Tevfik F.
    Neji, Radhouene
    Roujol, Sebastien
    O'Doherty, Jim
    Xue, Hui
    Barrington, Sally F.
    Schaeffter, Tobias
    Razavi, Reza
    Marsden, Paul
    Kellman, Peter
    Plein, Sven
    Chiribiri, Amedeo
    [J]. EUROPEAN JOURNAL OF HYBRID IMAGING, 2019, 3 (01):