Absolute quantification of myocardial blood flow with 13N-ammonia and 3-dimensional PET

被引:41
作者
Schepis, Tiziano [1 ]
Gaemperli, Oliver [1 ]
Treyer, Valerie [1 ]
Valenta, Ines [1 ]
Burger, Cyrill [1 ]
Koepfli, Pascal [1 ]
Namdar, Mehdi [1 ]
Adachi, Itaru [4 ]
Alkadhi, Hatem [2 ]
Kaufmann, Philipp A. [1 ,3 ]
机构
[1] Univ Zurich Hosp, Ctr Cardiovasc, Clin Nucl Med, CH-8091 Zurich, Switzerland
[2] Univ Zurich Hosp, Inst Diagnos Radiol, CH-8091 Zurich, Switzerland
[3] Univ Zurich, Ctr Integrat Human Physiol, CH-8091 Zurich, Switzerland
[4] Osaka Med Coll, Dept Radiol, Takatsuki, Osaka 569, Japan
关键词
myocardial blood flow; 3-dimensional PET; N-13-NH3; image reconstruction algorithms;
D O I
10.2967/jnumed.107.044099
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to compare 2-dimensional (2D) and 3-dimensional (3D) dynamic PET for the absolute quantification of myocardial blood flow (MBF) with N-13-ammonia (N-13-NH3)Methods: 2D and 3D MBF measurements were collected from 21 patients undergoing cardiac evaluation at rest (n = 14) and during standard adenosine stress (n = 7). A lutetium yttrium oxyorthosilicate-based PET/CT system with retractable septa, enabling the sequential acquisition of 2D and 3D images within the same patient and study, was used. All 2D studies were performed by injecting 700-900 MBq of N-13-NH3. For 14 patients, 3D studies were performed with the same injected N-13-NH3 dose as that used in 2D studies. For the remaining 7 patients, 3D images were acquired with a lower dose of N-13-NH3, that is, 500 MBq. 2D images reconstructed by use of filtered back-projection (FBP) provided the reference standard for MBF measurements. 3D images were reconstructed by use of Fourier rebinning (FORE) with FBP (FORE-FBP), FORE with ordered-subsets expectation maximization (FORE-OSEM), and a reprojection algorithm (RP). Results: Global MBF measurements derived from 3D PET with FORE-FBP (r = 0.97), FORE-OSEM (r = 0.97), and RP (r = 0.97) were well correlated with those derived from 2D FBP (all Ps < 0.0001). The mean +/- SD differences in global MBF measurements between 3D FORE-FBP and 2D FBP and between 3D FORE-OSEM and 2D FBP were 0.01 +/- 0.14 and 0.01 +/- 0.15 mL/min/g, respectively. The mean +/- SD difference in global MBF measurements between 3D RP and 2D FBP was 0.00 +/- 0.16 mL/min/g. The best correlation between 2D PET and 3D PET performed with the lower injected activity was found for the 3D FORE-FBP reconstruction algorithm (r = 0.95,P< 0.001). Conclusion: For this scanner type, quantitative measurements of MBF with 3D PET and N-13-NH3 were in excellent agreement with those obtained with the 2D technique, even when a lower activity was injected.
引用
收藏
页码:1783 / 1789
页数:7
相关论文
共 50 条
  • [31] 2098 Magnetic resonance imaging at 3 Tesla to quantify regional myocardial blood flow after myocardial infarction: comparison with 13N-ammonia positron emission tomography and microspheres
    Karl H Schuleri
    Kakuya Kitagawa
    Riikka Lautamäki
    Robert Evers
    Frank M Bengel
    Albert C Lardo
    Journal of Cardiovascular Magnetic Resonance, 10 (Suppl 1)
  • [32] Coronary calcium score scans for attenuation correction of quantitative PET/CT 13N-ammonia myocardial perfusion imaging
    Nina Burkhard
    Bernhard A. Herzog
    Lars Husmann
    Aju P. Pazhenkottil
    Irene A. Burger
    Ronny R. Buechel
    Ines Valenta
    Christophe A. Wyss
    Philipp A. Kaufmann
    European Journal of Nuclear Medicine and Molecular Imaging, 2010, 37 : 517 - 521
  • [33] Coronary calcium score scans for attenuation correction of quantitative PET/CT 13N-ammonia myocardial perfusion imaging
    Burkhard, Nina
    Herzog, Bernhard A.
    Husmann, Lars
    Pazhenkottil, Aju P.
    Burger, Irene A.
    Buechel, Ronny R.
    Valenta, Ines
    Wyss, Christophe A.
    Kaufmann, Philipp A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (03) : 517 - 521
  • [34] Estimation of Microvascular Dysfunction by Using 13N-Ammonia Positron Emission Tomography with Quantitative Myocardial Blood Flow Analysis in Chronic Coronary Syndrome
    Imai, Shogo
    Kiriyama, Tomonari
    Kanaya, Koji
    Aoyama, Satoe
    Takano, Hitoshi
    Kumita, Shin-ichiro
    JOURNAL OF NIPPON MEDICAL SCHOOL, 2023, 90 (02) : 228 - 236
  • [35] Combined evaluation of myocardial perfusion and coronary morphology in the identification of subclinical CAD Radiation exposure of 13N-ammonia PET/CT
    Vincenti, G.
    Quercioli, A.
    Zaidi, H.
    Nkoulou, R.
    Dewarrat, S.
    Rager, O.
    Ambrosio, G.
    Seimbille, Y.
    Mach, F.
    Ratib, O.
    Schindler, T. H.
    NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2010, 49 (05): : 173 - 182
  • [36] Uniformity and repeatability of normal resting myocardial blood flow in rats using [13N]-ammonia and small animal PET
    Lamoureux, Marc
    Thorn, Stephanie
    Dumouchel, Tyler
    Renaud, Jennifer M.
    Klein, Ran
    Mason, Samantha
    Lortie, Mireille
    DaSilva, Jean N.
    Beanlands, Rob S.
    deKemp, Robert A.
    NUCLEAR MEDICINE COMMUNICATIONS, 2012, 33 (09) : 917 - 925
  • [37] Comparison between N13NH3-PET and 99mTc-Tetrofosmin-CZT SPECT in the evaluation of absolute myocardial blood flow and flow reserve
    Raffaele Giubbini
    Mattia Bertoli
    Rexhep Durmo
    Mattia Bonacina
    Alessia Peli
    Ilio Faggiano
    Domenico Albano
    Elisa Milan
    Eli Stern
    Barbara Paghera
    Carlo Rodella
    Elisabetta Cerudelli
    Marina Gazzilli
    Francesco Dondi
    Francesco Bertagna
    Luca Camoni
    Journal of Nuclear Cardiology, 2021, 28 : 1906 - 1918
  • [38] Comparison between N13NH3-PET and99mTc-Tetrofosmin-CZT SPECT in the evaluation of absolute myocardial blood flow and flow reserve
    Giubbini, Raffaele
    Bertoli, Mattia
    Durmo, Rexhep
    Bonacina, Mattia
    Peli, Alessia
    Faggiano, Ilio
    Albano, Domenico
    Milan, Elisa
    Stern, Eli
    Paghera, Barbara
    Rodella, Carlo
    Cerudelli, Elisabetta
    Gazzilli, Marina
    Dondi, Francesco
    Bertagna, Francesco
    Camoni, Luca
    JOURNAL OF NUCLEAR CARDIOLOGY, 2021, 28 (05) : 1906 - 1918
  • [39] Added Value of Transluminal Attenuation Gradient to Qualitative CCTA Ischemia Detection as Determined by 13N-ammonia PET Quantitative Myocardial Perfusion
    Monroy-Gonzalez, Andrea
    Alexanderson-Rosas, Erick
    Perez-Orpinel, Oscar
    Dobrolinska, Magdalena
    Tio, Rene
    de Groot, Jan Cees
    Slart, Riemer
    Prakken, Niek
    DIAGNOSTICS, 2020, 10 (09)
  • [40] Simple and Patlak models for myocardial blood flow measurements with nitrogen-13-ammonia and PET in humans
    Kitsukawa, S
    Yoshida, K
    Mullani, N
    Nakagawa, K
    Shimada, K
    Takami, A
    Himi, T
    Masuda, Y
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (07) : 1123 - 1128