Potential contraindications to scleral lens wear

被引:25
作者
Fadel, Daddi [1 ]
Kramer, Elise [2 ]
机构
[1] DOptom, Rome, Italy
[2] OD, Miami, FL USA
关键词
Scleral lens; Indications; Contraindications; Endothelial cell density; Fuchs' dystrophy; Intraocular pressure; Glaucoma; Drainage devices; Overnight wear; Patient expectations; OCULAR SURFACE ECOSYSTEM; OPEN-ANGLE GLAUCOMA; ENDOTHELIAL-CELL-DENSITY; KERATOCONJUNCTIVITIS SICCA SECONDARY; CORNEAL EPITHELIAL DEFECT; STEVENS-JOHNSON SYNDROME; VERSUS-HOST-DISEASE; POST-LASIK ECTASIA; CONTACT-LENSES; PROSTHETIC REPLACEMENT;
D O I
10.1016/j.clae.2018.10.024
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Research and reviews have resulted in clear indications for scleral lens (SL) wear. Those indications include visual rehabilitation; therapeutic use in managing ocular surface diseases, lid and orbit disorders; and refractive correction to enhance visual quality, comfort and quality of life. In some cases, the use of SLs may be contraindicated: the presence of low endothelial cell density; Fuchs' endothelial corneal dystrophy; glaucoma (because of the risk of an increase in intraocular pressure and the existence and location of draining devices and blebs); or overnight wear. While the literature provides an extensive description of the indications for scleral lens wear, the authors recognize that there is no paper reporting the contraindications to their use. The aim of this review is to illustrate the conditions for which SL wear is potentially contraindicated or requires caution. Improved knowledge of SL limits should reduce the risk of adverse events and increase the likelihood of fitting success.
引用
收藏
页码:92 / 103
页数:12
相关论文
共 277 条
[91]  
Huggert A, 1951, ACTA OPHTHALMOL, V29, P475
[92]   Risk factors for reduced corneal endothelial cell density before cataract surgery [J].
Ishikawa, A .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (11) :1982-1992
[93]  
ITOI M, 1989, CORNEA, V8, P2
[94]   Comprehensive approach to ocular consequences of Stevens Johnson Syndrome - the aftermath of a systemic condition [J].
Iyer, Geetha ;
Srinivasan, Bhaskar ;
Agarwal, Shweta ;
Muralidharan, Seema Kamala ;
Arumugam, Sumathi .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 252 (03) :457-467
[95]   Boston Scleral Lens Prosthetic Device for treatment of severe dry eye in chronic graft-versus-host disease [J].
Jacobs, Deborah S. ;
Rosenthal, Perry .
CORNEA, 2007, 26 (10) :1195-1199
[96]   Outcomes of penetrating keratoplasty in keratoconus [J].
Javadi, MA ;
Motlagh, BF ;
Jafarinasab, MR ;
Rabbanikhah, Z ;
Anissian, A ;
Souri, H ;
Yazdani, S .
CORNEA, 2005, 24 (08) :941-946
[97]   Predicting scleral GP lens entrapped tear layer oxygen tensions [J].
Jaynes, Jared M. ;
Edrington, Timothy B. ;
Weissman, Barry A. .
CONTACT LENS & ANTERIOR EYE, 2015, 38 (01) :44-47
[98]  
Johns K. L., 2016, CONTACT LENS SPECTRU
[99]  
Johns K. L., 2011, I SITE E NEWSLET JUL
[100]   Glaucoma [J].
Jonas, Jost B. ;
Aung, Tin ;
Bourne, Rupert R. ;
Bron, Alain M. ;
Ritch, Robert ;
Panda-Jonas, Songhomitra .
LANCET, 2017, 390 (10108) :2183-2193