Risk factors for hypertensive phase after Ahmed glaucoma valve implantation

被引:9
|
作者
Ozalp, Onur [1 ]
Ilguy, Serdar [2 ]
Atalay, Eray [3 ]
Simsek, Tulay [3 ]
Yildirim, Nilgun [3 ]
机构
[1] Devrek State Hosp, Ophthalmol Clin, Zonguldak, Turkey
[2] Yunus Emre State Hosp, Ophthalmol Clin, Eskisehir, Turkey
[3] Eskisehir Osmangazi Univ, Dept Ophthalmol, Med Sch, Eskisehir, Turkey
关键词
Ahmed glaucoma valve; Glaucoma; Hypertensive phase; Risk factors; DIFFERENT BIOMATERIALS; REFRACTORY GLAUCOMA; TREATMENT OUTCOMES; TENON ADVANCEMENT; DRAINAGE DEVICES; PLATE MOLTENO; TUBE EXPOSURE; SILICONE; POLYPROPYLENE; TRABECULECTOMY;
D O I
10.1007/s10792-021-02009-3
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To investigate the risk factors and the clinical characteristics of the hypertensive phase (HP) after Ahmed glaucoma valve (AGV) implantation. Methods This retrospective study included 60 eyes of 57 patients who underwent AGV implantation and with at least 1-year follow-up. HP was defined as intraocular pressure (IOP) > 21 mmHg in the first 3 months after the surgery. Independent samples t-test and Chi-square test were used to compare differences in patients with the HP and the non-HP groups. Univariable and multivariable logistic regression analyses were used to determine the risk factors for the development of the HP. Statistical significance was assumed at p < 0.05 level. Results HP was observed in 31 eyes (51.7%) with an average peak IOP of 27.6 +/- 4.5 mmHg (range 22-40 mmHg). The resolution of HP was noted in 27 eyes (87.1%) at the 3rd month postoperative visit. The number of glaucoma medications at the last postoperative visit and IOP values from 1 month to 1 year were significantly higher in the HP group (all p < 0.05). Patients with traumatic glaucoma showed the highest rate (83.3%) of HP development. In the multivariable analysis, a preoperative IOP > 30 mmHg (p = 0.03, OR:5.82; reference: <= 25 mmHg) and younger age (41-64 years, p = 0.02, OR:8.49; <= 40 years, p = 0.001, OR:19.62; reference: >= 65 years) were independently associated with the occurrence of HP. Conclusion Hypertensive phase was observed in half of the patients undergoing AGV implantation. A higher mean preoperative IOP and younger age were risk factors for HP development. Although the majority resolved at the 3-month visit, eyes with HP had higher mean IOPs and required more IOP lowering medications.
引用
收藏
页码:147 / 156
页数:10
相关论文
共 50 条
  • [21] Strabismus After Ahmed Glaucoma Valve Implantation
    Robbins, Laura
    Goseki, Toshiaki
    Law, Simon K.
    Nouri-Mahdavi, Kouros
    Caprioli, Joseph
    Coleman, Anne L.
    Giaconi, Joann A.
    Demer, Joseph L.
    Velez, Federico G.
    Pineles, Stacy L.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2021, 222 : 1 - 5
  • [22] Risk factors for the hypertensive phase after implantation of a glaucoma drainage device
    Jung, Kyoung In
    Park, Chan Kee
    ACTA OPHTHALMOLOGICA, 2016, 94 (05) : e260 - e267
  • [23] Ocular biometric changes after Ahmed glaucoma valve implantation
    Miraftabi, Arezoo
    Lotfi, Mahboubeh
    Nilforushan, Naveed
    Abdolalizadeh, Parya
    Jafari, Samira
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (01) : 120 - 124
  • [24] Superior versus Inferior Ahmed Glaucoma Valve Implantation
    Pakravan, Mohammad
    Yazdani, Shahin
    Shahabi, Camelia
    Yaseri, Mehdi
    OPHTHALMOLOGY, 2009, 116 (02) : 208 - 213
  • [25] Efficacy of Ahmed Glaucoma Valve Implantation on Neovascular Glaucoma
    Xie, Zhan
    Liu, Hai
    Du, Mulong
    Zhu, Min
    Tighe, Sean
    Chen, Xue
    Yuan, Zhilan
    Sun, Hong
    INTERNATIONAL JOURNAL OF MEDICAL SCIENCES, 2019, 16 (10): : 1371 - 1376
  • [26] Ahmed Glaucoma Valve Implantation in Jordan: Indications and Complications
    Alqudah, Asem A.
    Obaidi, Ahmed G.
    Al Zoubi, Mohammad
    Aleshawi, Abdelwahab
    CLINICAL OPHTHALMOLOGY, 2024, 18 : 3581 - 3590
  • [27] Ahmed Glaucoma Valve Implantation for Refractory Glaucoma in a Tertiary Hospital in Brazil
    Abe, Ricardo Yuji
    Tavares, Carla Melo
    Schimiti, Rui Barroso
    Cabral Vasconcellos, Jose Paulo
    Costa, Vital Paulino
    JOURNAL OF OPHTHALMOLOGY, 2015, 2015
  • [28] Intravitreal bevacizumab and Ahmed glaucoma valve implantation in patients with neovascular glaucoma
    Zhang, Hai-Tao
    Yang, Yu-Xin
    Xu, Ying-Ying
    Yang, Rui-Min
    Wang, Bao-Jun
    Hu, Jun-Xi
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2014, 7 (05) : 837 - 842
  • [29] The effect of the hypertensive phase on the long-term outcomes of Ahmed glaucoma valve (AGV) implantation
    Naveed Nilforushan
    Kiana Hassanpour
    Fatemeh Vafaei
    Maryam Yadgari
    International Ophthalmology, 2022, 42 : 3739 - 3747
  • [30] The effect of the hypertensive phase on the long-term outcomes of Ahmed glaucoma valve (AGV) implantation
    Nilforushan, Naveed
    Hassanpour, Kiana
    Vafaei, Fatemeh
    Yadgari, Maryam
    INTERNATIONAL OPHTHALMOLOGY, 2022, 42 (12) : 3739 - 3747