Quantification of transient signals in multiple collector inductively coupled plasma mass spectrometry: accurate lead isotope ratio determination by laser ablation of individual fluid inclusions

被引:44
作者
Pettke, Thomas [1 ,2 ]
Oberli, Felix [2 ]
Audetat, Andreas [3 ]
Wiechert, Uwe [2 ,4 ]
Harris, Caroline R. [2 ,5 ]
Heinrich, Christoph A. [2 ]
机构
[1] Univ Bern, Inst Geol Sci, CH-3012 Bern, Switzerland
[2] ETH, Inst Geochem & Petrol, CH-8092 Zurich, Switzerland
[3] Univ Bayreuth, Bayer Geoinst, D-95440 Bayreuth, Germany
[4] Free Univ Berlin, Inst Geol Wissensch, D-12249 Berlin, Germany
[5] Stanford Univ, Stanford, CA 94305 USA
基金
瑞士国家科学基金会;
关键词
MC-ICP-MS; MELT INCLUSIONS; STRONTIUM ISOTOPES; DATA-ACQUISITION; MOLE-GRANITE; DOUBLE SPIKE; PRECISION; CONSTRAINTS; HETEROGENEITY; AUSTRALIA;
D O I
10.1039/c0ja00140f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work establishes the analytical protocol for accurate Pb isotopic analysis of fast transient signals by multiple-collector ICP-MS instruments. Individual synthetic fluid inclusions of known Pb and Tl isotopic compositions (dissolved SRM 981 with or without SRM 997 from NIST, enclosed in quartz by a hydrothermal crack annealing technique) were liberated by 193 nm UV laser ablation (LA). Data were recorded on Faraday detectors, for which correction schemes for bias in amplifier response ("tau correction") are presented and evaluated. tau-Corrected Pb isotope data reveal LA-induced isotope fractionation amounting to similar to 0.5% amu(-1) for Pb isotopes over the course of an entire fluid inclusion ablation. Instrumental mass bias correction was effected within-run using Tl provided by the fluid inclusion itself or admixed to the ablation aerosol via desolvated nebulization. Isotope ratios derived from the transient signals were either based on individual readings or on bulk signal integration, of which the latter produces significantly more accurate data. The external precision achieved by ablating SRM 610 glass with a 60 mm beam is +/-0.011% (2 SD, relative) for (208)Pb/(206)Pb and (207)Pb/(206)Pb ratios and +/-0.032% for Pb isotope ratios normalized to mass 204 (n = 18). Inclusion-to-inclusion reproducibilities (n = 11; similar to 0.1 ng Pb per inclusion) are +/-0.05% (2 SD; (208)Pb/(206)Pb and (207)Pb/(206)Pb) and +/-0.13% ((20x)Pb/(204)Pb), respectively; inclusions containing as little as 0.005 ng Pb returned +/-0.1% and +/-0.8%. These results are accurate as demonstrated by analysis of synthetic fluid inclusions containing SRM 981 Pb. The analytical protocol presented here for measuring isotope ratios on minute analyte quantities by multiple-collector ICP-MS in fast transient signal mode has great potential for applications to geochemical, archaeological, environmental and possibly biochemical problems.
引用
收藏
页码:475 / 492
页数:18
相关论文
共 46 条
[1]   Precise and accurate isotopic measurements using multiple-collector ICPMS [J].
Albarède, F ;
Telouk, P ;
Blichert-Toft, J ;
Boyet, M ;
Agranier, A ;
Nelson, B .
GEOCHIMICA ET COSMOCHIMICA ACTA, 2004, 68 (12) :2725-2744
[2]   Validation of LA-ICP-MS fluid inclusion analysis with synthetic fluid inclusions [J].
Allan, MM ;
Yardley, BWD ;
Forbes, LJ ;
Shmulovich, KI ;
Banks, DA ;
Shepherd, TJ .
AMERICAN MINERALOGIST, 2005, 90 (11-12) :1767-1775
[3]  
Audétat A, 2000, GEOCHIM COSMOCHIM AC, V64, P3373
[4]   Formation of a magmatic-hydrothermal ore deposit:: Insights with LA-ICP-MS analysis of fluid inclusions [J].
Audétat, A ;
Günther, D ;
Heinrich, CA .
SCIENCE, 1998, 279 (5359) :2091-2094
[5]   Causes for large-scale metal zonation around mineralized plutons:: Fluid inclusion LA-ICP-MS evidence from the Mole Granite, Australia [J].
Audétat, A ;
Günther, D ;
Heinrich, CA .
ECONOMIC GEOLOGY AND THE BULLETIN OF THE SOCIETY OF ECONOMIC GEOLOGISTS, 2000, 95 (08) :1563-1581
[6]   Pb isotopic analysis of standards and samples using a 207Pb-204Pb double spike and thallium to correct for mass bias with a double-focusing MC-ICP-MS [J].
Baker, J ;
Peate, D ;
Waight, T ;
Meyzen, C .
CHEMICAL GEOLOGY, 2004, 211 (3-4) :275-303
[7]   Revised exponential model for mass bias correction using an internal standard for isotope abundance ratio measurements by multi-collector inductively coupled plasma mass spectrometry [J].
Baxter, DC ;
Rodushkin, I ;
Engström, E ;
Malinovsky, D .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2006, 21 (04) :427-430
[8]   A new approach to single shot laser ablation analysis and its application to in situ Pb/U geochronology [J].
Cottle, J. M. ;
Horstwood, M. S. A. ;
Parrish, R. R. .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2009, 24 (10) :1355-1363
[9]   ABSOLUTE ISOTOPIC ABUNDANCE AND THE ATOMIC WEIGHT OF A REFERENCE SAMPLE OF THALLIUM [J].
DUNSTAN, LP ;
GRAMLICH, JW ;
BARNES, IL ;
PURDY, WC .
JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS, 1980, 85 (01) :1-10
[10]   Compositional heterogeneity in NIST SRM 610-617 glasses [J].
Eggins, SM ;
Shelley, JMG .
GEOSTANDARDS NEWSLETTER-THE JOURNAL OF GEOSTANDARDS AND GEOANALYSIS, 2002, 26 (03) :269-286