Open-circuit faults diagnosis and Fault-Tolerant Control scheme based on Sliding-Mode Observer for DFIG back-to-back converters: Wind turbine applications

被引:14
|
作者
Kamarzarrin, Mehrnoosh [1 ]
Refan, Mohammad Hossein [1 ]
Amiri, Parviz [1 ]
机构
[1] Shahid Rajaee Teacher Training Univ, Fac Elect Engn, Tehran, Iran
关键词
Open-circuit fault; DFIG; Fault-Tolerant Control; Fault diagnosis; Sliding Mode Observer; ENERGY-CONVERSION SYSTEM; ELECTRONIC CONVERTERS; PMSG DRIVE; TIME;
D O I
10.1016/j.conengprac.2022.105235
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
One of the most common types of wind turbines is the Doubly-Fed Induction Generator with a back-to-back converter. The Insulated Gate Bipolar Transistor switch's open-circuit fault rate compared to the fault total rate in the wind turbine is noteworthy. The converter Insulated Gate Bipolar Transistor open-circuit causes a drawback in output current and as a result, the production performance of the turbine is reduced. In this article, a new method is presented for multiple Insulated Gate Bipolar Transistor open-circuit faults for open -circuit faults diagnosis. After the fault occurs, to maintain the performance of the turbine, fault compensation is performed based on the new Fault-Tolerant Control scheme. The proposed method is inexpensive, and for fault detection and location determining no need for additional sensors and hardware. This method uses residual output based on the Sliding Mode Observer with SAT function to detect faulty phase and overcome chattering Doubly-Fed Induction Generator converter. To residual evaluate and reduce the false alarm rate against changes in operating points and transient currents, the adaptive threshold is used. For efficient control of active or reactive power and dc-link voltage, a six-leg converter control based on Simplified Space Pulse Width Modulation is replaced by a five-leg converter based on Space Vector Modulation. Several experimental results using hardware in the loop Doubly-Fed Induction Generator test setup with a back-to-back converter are presented. It is shown the fault diagnostic algorithm is effective and robust against false alarms for both rotor and stator-side converters. The experimental result presents that the Fault Tolerant Control scheme can make power switch fault easily managed by the hardware reconfiguration and new control strategy adjusting.
引用
收藏
页数:28
相关论文
共 50 条
  • [1] Open-circuit faults diagnosis in back-to-back converters of DF wind turbine
    Zhao, Hongshan
    Cheng, Liangliang
    IET RENEWABLE POWER GENERATION, 2017, 11 (04) : 417 - 424
  • [2] Multiple Open-Circuit Faults Diagnosis in Back-to-Back Converters of PMSG Drives for Wind Turbine Systems
    Jlassi, Imed
    Estima, Jorge O.
    El Khil, Sejir Khojet
    Bellaaj, Najiba Mrabet
    Marques Cardoso, Antonio J.
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (05) : 2689 - 2702
  • [3] Open-switch Fault Diagnosis Based on Luenberger Observer in Back-to-Back Converters of Wind Turbines with DFIG
    Khamseh, Siamak Afshar
    Mohammadbeigi, Amir
    2019 6TH INTERNATIONAL CONFERENCE ON CONTROL, DECISION AND INFORMATION TECHNOLOGIES (CODIT 2019), 2019, : 1326 - 1331
  • [4] Fault Diagnosis and Fault-Tolerant Control Scheme for Open-Circuit Faults in Three-Stepped Bridge Converters
    Shu, Cheng
    Wei, Li
    Rong-Jun, Ding
    Te-Fang, Chen
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2017, 32 (03) : 2203 - 2214
  • [5] Integral sliding mode control for back-to-back converter of DFIG wind turbine system
    Merabet, Adel
    Al-Durra, Ahmed
    Debouza, Mahdi
    Tanvir, Aman A.
    Eshaft, Hisham
    JOURNAL OF ENGINEERING-JOE, 2020, 2020 (10): : 834 - 842
  • [6] High order sliding mode observer-based fault-tolerant control scheme for DFIG in wind energy applications with model predictive controller
    Sarika, S.
    Mary, S. Anitha Janet
    AUTOMATIKA, 2024, 65 (03) : 793 - 802
  • [7] A Fault-Tolerant MTPA Control Strategy of Five-Phase Flux-Intensifying Fault-Tolerant Permanent-Magnet Motor With Sliding-Mode Disturbance Observer Under Open-Circuit and Short-Circuit Faults
    Zhang, Li
    Dong, Chenyang
    Zhu, Xiaoyong
    Chen, Xi
    Pei, Zifeng
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2024, 71 (11) : 13650 - 13658
  • [8] Backstepping sliding mode fault-tolerant control for the wind turbine system with disturbance observer
    Ma, Chenyuan
    He, Xinlin
    Xie, Beibei
    Sun, Weipeng
    Zhao, Daoli
    Liao, Weili
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART I-JOURNAL OF SYSTEMS AND CONTROL ENGINEERING, 2022, 236 (09) : 1667 - 1678
  • [9] Multiple Open-Circuit Fault Diagnosis for Back-to-Back Converter of PMSG Wind Generation System Based on Instantaneous Amplitude Estimation
    Xu, Shuiqing
    Tao, Songbing
    Zheng, Weixing
    Chai, Yi
    Ma, Mingyao
    Ding, Lijian
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [10] Neural Network based Open-circuit Fault Diagnosis for Three-Level Neutral-Point-Clamped Back-to-Back Converters
    Zhang, Xinqing
    Li, Zhen
    Zhang, Zhenkun
    Zhang, Mingyuan
    Chen, Haoyu
    Zhang, Zhenbin
    6TH IEEE INTERNATIONAL CONFERENCE ON PREDICTIVE CONTROL OF ELECTRICAL DRIVES AND POWER ELECTRONICS (PRECEDE 2021), 2021, : 748 - 752