Denoising of Raman spectroscopy for biological samples based on empirical mode decomposition

被引:9
作者
Leon-Bejarano, Fabiola [1 ]
Ramirez-Elias, Miguel [1 ]
Mendez, Martin O. [1 ]
Dorantes-Mendez, Guadalupe [1 ]
del Carmen Rodriguez-Aranda, Ma. [2 ]
Alba, Alfonso [1 ]
机构
[1] Univ Autonoma San Luis Potosi, Fac Ciencias, Av Salvador Nava Mtz S-N, San Luis Potosi 78290, SLP, Mexico
[2] Univ Autonoma San Luis Potosi, Coordinac Innovac & Aplicac Ciencia & Tecnol, Av Sierra Leona 550,Col Lomas 2a, San Luis Potosi, SLP, Mexico
来源
INTERNATIONAL JOURNAL OF MODERN PHYSICS C | 2017年 / 28卷 / 09期
关键词
Background removal; autofluorescence; signal denoising; time frequency analysis; Raman spectroscopy; HIGHLY FLUORESCENT SAMPLES; SPECTRA; ALGORITHM; SUBTRACTION; SKIN;
D O I
10.1142/S0129183117501169
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Raman spectroscopy of biological samples presents undesirable noise and fluorescence generated by the biomolecular excitation. The reduction of these types of noise is a fundamental task to obtain the valuable information of the sample under analysis. This paper proposes the application of the empirical mode decomposition (EMD) for noise elimination. EMD is a parameter free and adaptive signal processing method useful for the analysis of nonstationary signals. EMD performance was compared with the commonly used Vancouver algorithm (VRA) through artificial data (Teflon), synthetic (Vitamin E and paracetamol) and biological (Mouse brain and human nails) Raman spectra. The correlation coefficient (rho) was used as performance measure. Results on synthetic data showed a better performance of EMD (rho = 0.52) at high noise levels compared with VRA (rho = 0.19). The methods with simulated fluorescence added to artificial material exhibited a similar shape of fluorescence in both cases (rho = 0.95 for VRA and rho = 0.93 for EMD). For synthetic data, Raman spectra of vitamin E were used and the results showed a good performance comparing both methods (rho = 0.95 for EMD and rho = 0.99 for VRA). Finally, in biological data, EMD and VRA displayed a similar behavior (rho = 0.85 for EMD and rho = 0.96 for VRA), but with the advantage that EMD maintains small amplitude Raman peaks. The results suggest that EMD could be an effective method for denoising biological Raman spectra, EMD is able to retain information and correctly eliminates the fluorescence without parameter tuning.
引用
收藏
页数:18
相关论文
共 30 条
[1]   Use of Raman spectroscopy in the analysis of nickel allergy [J].
Alda, Javier ;
Castillo-Martinez, Claudio ;
Valdes-Rodriguez, Rodrigo ;
Hernandez-Blanco, Diana ;
Moncada, Benjamin ;
Gonzalezc, Francisco J. .
JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (06)
[2]  
[Anonymous], 2003, INTRO RAMAN SPECTROS, DOI DOI 10.1016/B978-012254105-6/50004-4
[3]   Secondary structure of α-synuclein oligomers:: Characterization by Raman and atomic force microscopy [J].
Apetri, MM ;
Maiti, NC ;
Zagorski, MG ;
Carey, PR ;
Anderson, VE .
JOURNAL OF MOLECULAR BIOLOGY, 2006, 355 (01) :63-71
[4]   A background elimination method based on linear programming for Raman spectra [J].
Baek, Sung-June ;
Park, Aaron ;
Shen, Aiguo ;
Hu, Jimming .
JOURNAL OF RAMAN SPECTROSCOPY, 2011, 42 (11) :1987-1993
[5]   ECG signal denoising and baseline wander correction based on the empirical mode decomposition [J].
Blanco-Velasco, Manuel ;
Weng, Binwei ;
Barner, Kenneth E. .
COMPUTERS IN BIOLOGY AND MEDICINE, 2008, 38 (01) :1-13
[6]   Label-free surface-enhanced Raman spectroscopy of biofluids: fundamental aspects and diagnostic applications [J].
Bonifacio, Alois ;
Cervo, Silvia ;
Sergo, Valter .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (27) :8265-8277
[7]  
Cadush P. J., 2012, INT J SPECTROSC, V44, P1587
[8]   Raman database of amino acids solutions: a critical study of Extended Multiplicative Signal Correction [J].
Candeloro, Patrizio ;
Grande, Elisabetta ;
Raimondo, Raffaella ;
Di Mascolo, Daniele ;
Gentile, Francesco ;
Coluccio, Maria Laura ;
Perozziello, Gerardo ;
Malara, Natalia ;
Francardi, Marco ;
Di Fabrizio, Enzo .
ANALYST, 2013, 138 (24) :7331-7340
[9]  
Cohen I., 2009, Noise Reduction in Speech Processing, V2
[10]   Automatic screening of Obstructive Sleep Apnea from the ECG based on Empirical Mode Decomposition and Wavelet Analysis [J].
Corthout, J. ;
Van Huffel, S. ;
Mendez, M. O. ;
Bianchi, A. M. ;
Penzel, T. ;
Cerutti, S. .
2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, :3608-+