Determination of antihypertensive and anti-ulcer agents from surface water with solid-phase extraction-liquid chromatography-electrospray ionization tandem mass spectrometry

被引:32
|
作者
Varga, Renata [1 ]
Somogyvari, Ivan [1 ]
Eke, Zsuzsanna [1 ]
Torkos, Kornel [1 ]
机构
[1] Eotvos Lorand Univ, Joint Res & Training Lab Separat Tech, H-1117 Budapest, Hungary
关键词
Anti-ulcer agents; Antihypertensive drugs; Water analysis; Liquid chromatography-tandem mass spectrometry; Solid-phase extraction; Post-extraction spike method; SEWAGE-TREATMENT PLANTS; 9 BASIC PHARMACEUTICALS; RAY CONTRAST-MEDIA; ENVIRONMENTAL-SAMPLES; WASTE-WATER; AQUEOUS SAMPLES; ANALYTICAL METHODOLOGIES; LC/MS/MS ANALYSES; ION SUPPRESSION; ILLICIT DRUGS;
D O I
10.1016/j.talanta.2010.11.030
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Pharmaceuticals are emerging contaminants in surface water and they must be measured to follow their effects on the aquatic environment. We developed a solid-phase extraction and liquid chromatography-electrospray ionization tandem mass spectrometry (SPE-LC-ESI-MS/MS) method for the determination of twenty-six pharmaceutical compounds - which belong to antihypertensive and anti-ulcer agents - from surface water samples. The selection of pharmaceuticals was based on usage frequency in Hungary. During method development Oasis HLB, SampliQ Polymer SCX and Si-SCX SPE cartridges were tested. As LC eluent ammonium formate. ammonium acetate buffers at pH 3 and 5 were investigated and for quantitation both matrix-matched and internal standard calibration was used. For matrix effect assessment post-extraction spike method was applied which can separate the extraction efficiency from ion suppression for better determination of recovery. Method detection limits (MDLs) varied between 0.2 and 10 ng/L. Precision of the method, calculated as relative standard deviation (RSD), ranged from 0.2 to 14.6% and from 1.2 to 22.4% for intra- and inter-day analysis, respectively. The method was applied to analyze Danube water samples. Measured average concentrations varied between 2 and 39 ng/L for eleven compounds and another one could be detected under LOQ (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:1447 / 1454
页数:8
相关论文
共 50 条
  • [31] Monitoring of antifouling agents in water samples by on-line solid-phase extraction-liquid chromatography-atmospheric pressure chemical ionization mass spectrometry
    Gimeno, RA
    Aguilar, C
    Marcé, RM
    Borrull, F
    JOURNAL OF CHROMATOGRAPHY A, 2001, 915 (1-2) : 139 - 147
  • [32] DETERMINATION OF TWO TEXTILE DYES IN WASTEWATER BY SOLID PHASE EXTRACTION AND LIQUID CHROMATOGRAPHY/ELECTROSPRAY IONIZATION TANDEM MASS SPECTROMETRY ANALYSIS
    Copaciu, Florina
    Coman, Virginia
    Simedru, Dorina
    Beldean-Galea, Simion
    Opris, Ocsana
    Ristoiu, Dumitru
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2013, 36 (12) : 1646 - 1660
  • [33] Compliance analysis of phenylurea and related compounds in drinking water by liquid chromatography/electrospray ionization/mass spectrometry coupled with solid-phase extraction
    Li, Yongtao
    George, John E.
    McCarty, Christina L.
    Wendelken, Steven C.
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1134 (1-2) : 170 - 176
  • [34] Solid-Phase Extraction/High-Performance Liquid Chromatography-Electrospray Mass Spectrometry to Determine Endocrine Disruptors in Water Samples
    L. Brossa
    E. Pocurull
    F. Borrull
    R. M. Marcé
    Chromatographia, 2004, 59 : 419 - 423
  • [35] Solid-phase extraction/high-performance liquid chromatography-electrospray mass spectrometry to determine endocrine disruptors in water samples
    Brossa, L
    Pocurull, E
    Borrull, F
    Marcé, RM
    CHROMATOGRAPHIA, 2004, 59 (7-8) : 419 - 423
  • [36] Simultaneous determination of fluoroquinolone, sulfonamide, and trimethoprim antibiotics in wastewater using tandem solid phase extraction and liquid chromatography-electrospray mass spectrometry
    Renew, JE
    Huang, CH
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1042 (1-2) : 113 - 121
  • [37] Determination of Ethiprole Enantiomers Residue in Rices Using Solid Phase Extraction-Liquid Chromatography Tandem Mass Spectrometry
    Zhang Hu
    Qian Ming-Rong
    Wang Xin-Quan
    Liu Fei
    Wang Xiang-Yun
    Xu Hao
    Qi Pei-Pei
    Wang Ming-Hua
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2012, 40 (06) : 883 - 887
  • [38] Determination of perfluorinated compounds in wastewater and river water samples by mixed hemimicelle-based solid-phase extraction before liquid chromatography-electrospray tandem mass spectrometry detection
    Zhao, Xiaoli
    Li, Jidong
    Shi, Yali
    Cai, Yaqi
    Mou, Shifen
    Jiang, Guibin
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1154 (1-2) : 52 - 59
  • [39] Simultaneous determination of gibberellic acid, indole-3-acetic acid and abscisic acid in wheat extracts by solid-phase extraction and liquid chromatography-electrospray tandem mass spectrometry
    Hou, Shengjie
    Zhu, Jiang
    Ding, Mingyu
    Lv, Guohua
    TALANTA, 2008, 76 (04) : 798 - 802
  • [40] Determination of some organic contaminants in water samples by solid-phase extraction and liquid chromatography tandem mass spectrometry
    Maldaner, Liane
    Jardim, Isabel C. S. F.
    TALANTA, 2012, 100 : 38 - 44