Determination of antihypertensive and anti-ulcer agents from surface water with solid-phase extraction-liquid chromatography-electrospray ionization tandem mass spectrometry

被引:32
|
作者
Varga, Renata [1 ]
Somogyvari, Ivan [1 ]
Eke, Zsuzsanna [1 ]
Torkos, Kornel [1 ]
机构
[1] Eotvos Lorand Univ, Joint Res & Training Lab Separat Tech, H-1117 Budapest, Hungary
关键词
Anti-ulcer agents; Antihypertensive drugs; Water analysis; Liquid chromatography-tandem mass spectrometry; Solid-phase extraction; Post-extraction spike method; SEWAGE-TREATMENT PLANTS; 9 BASIC PHARMACEUTICALS; RAY CONTRAST-MEDIA; ENVIRONMENTAL-SAMPLES; WASTE-WATER; AQUEOUS SAMPLES; ANALYTICAL METHODOLOGIES; LC/MS/MS ANALYSES; ION SUPPRESSION; ILLICIT DRUGS;
D O I
10.1016/j.talanta.2010.11.030
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Pharmaceuticals are emerging contaminants in surface water and they must be measured to follow their effects on the aquatic environment. We developed a solid-phase extraction and liquid chromatography-electrospray ionization tandem mass spectrometry (SPE-LC-ESI-MS/MS) method for the determination of twenty-six pharmaceutical compounds - which belong to antihypertensive and anti-ulcer agents - from surface water samples. The selection of pharmaceuticals was based on usage frequency in Hungary. During method development Oasis HLB, SampliQ Polymer SCX and Si-SCX SPE cartridges were tested. As LC eluent ammonium formate. ammonium acetate buffers at pH 3 and 5 were investigated and for quantitation both matrix-matched and internal standard calibration was used. For matrix effect assessment post-extraction spike method was applied which can separate the extraction efficiency from ion suppression for better determination of recovery. Method detection limits (MDLs) varied between 0.2 and 10 ng/L. Precision of the method, calculated as relative standard deviation (RSD), ranged from 0.2 to 14.6% and from 1.2 to 22.4% for intra- and inter-day analysis, respectively. The method was applied to analyze Danube water samples. Measured average concentrations varied between 2 and 39 ng/L for eleven compounds and another one could be detected under LOQ (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:1447 / 1454
页数:8
相关论文
共 50 条
  • [21] Estrogens and their conjugates: Determination in water samples by solid-phase extraction and liquid chromatography-tandem mass spectrometry
    Pedrouzo, Marta
    Borrull, Francesc
    Pocurull, Eva
    Maria Marce, Rosa
    TALANTA, 2009, 78 (4-5) : 1327 - 1331
  • [22] Determination of surfactants in surface water by solid-phase extraction, liquid chromatography and liquid chromatography-mass spectrometry
    Scullion, SD
    Clench, MR
    Cooke, M
    Ashcroft, AE
    JOURNAL OF CHROMATOGRAPHY A, 1996, 733 (1-2) : 207 - 216
  • [23] Determination of Antibiotics in Brazilian Surface Waters Using Liquid Chromatography-Electrospray Tandem Mass Spectrometry
    Locatelli, Marco Antonio F.
    Sodre, Fernando F.
    Jardim, Wilson F.
    ARCHIVES OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 2011, 60 (03) : 385 - 393
  • [24] Determination of chlormequat and mepiquat in pear, tomato, and wheat flour using on-line solid-phase extraction (Prospekt) coupled with liquid chromatography-electrospray ionization tandem mass spectrometry
    Riediker, S
    Obrist, H
    Varga, N
    Stadler, RH
    JOURNAL OF CHROMATOGRAPHY A, 2002, 966 (1-2) : 15 - 23
  • [25] CREATININE DETERMINATION IN URINE BY LIQUID CHROMATOGRAPHY-ELECTROSPRAY IONIZATION-TANDEM MASS SPECTROMETRY METHOD
    Derezinski, Pawel
    Klupczynska, Agnieszka
    Sawicki, Wojciech
    Kokot, Zenon J.
    ACTA POLONIAE PHARMACEUTICA, 2016, 73 (02): : 303 - 313
  • [26] Determination of pharmaceuticals from different therapeutic classes in wastewaters by liquid chromatography-electrospray ionization-tandem mass spectrometry
    Botitsi, Eleni
    Frosyni, Charalampia
    Tsipi, Despina
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 387 (04) : 1317 - 1327
  • [27] Identification of phase I metabolites of cardiovascular and anti-ulcer drugs in surface water samples with liquid-chromatography-mass spectrometry methods
    Varga, Renata
    Eke, Zsuzsanna
    Torkos, Kornel
    TALANTA, 2011, 85 (04) : 1920 - 1926
  • [28] On-line solid-phase extraction-ion-pair liquid chromatography-electrospray mass spectrometry for the trace determination of naphthalene monosulphonates in water
    Pocurull, E
    Aguilar, C
    Alonso, MC
    Barceló, D
    Borrull, F
    Marcé, RM
    JOURNAL OF CHROMATOGRAPHY A, 1999, 854 (1-2) : 187 - 195
  • [29] Determination of benzodiazepines, related pharmaceuticals and metabolites in water by solid-phase extraction and liquid-chromatography-tandem mass spectrometry
    Racamonde, Ines
    Rodil, Rosario
    Benito Quintana, Jose
    Villaverde-de-Saa, Eugenia
    Cela, Rafael
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1352 : 69 - 79
  • [30] Multiresidue determination of UV filters in water samples by solid-phase extraction and liquid chromatography with tandem mass spectrometry analysis
    Capriotti, Anna Laura
    Cavaliere, Chiara
    Piovesana, Susy
    Samperi, Roberto
    Stampachiacchiere, Serena
    Ventura, Salvatore
    Lagana, Aldo
    JOURNAL OF SEPARATION SCIENCE, 2014, 37 (20) : 2882 - 2891