Determination of antihypertensive and anti-ulcer agents from surface water with solid-phase extraction-liquid chromatography-electrospray ionization tandem mass spectrometry

被引:32
|
作者
Varga, Renata [1 ]
Somogyvari, Ivan [1 ]
Eke, Zsuzsanna [1 ]
Torkos, Kornel [1 ]
机构
[1] Eotvos Lorand Univ, Joint Res & Training Lab Separat Tech, H-1117 Budapest, Hungary
关键词
Anti-ulcer agents; Antihypertensive drugs; Water analysis; Liquid chromatography-tandem mass spectrometry; Solid-phase extraction; Post-extraction spike method; SEWAGE-TREATMENT PLANTS; 9 BASIC PHARMACEUTICALS; RAY CONTRAST-MEDIA; ENVIRONMENTAL-SAMPLES; WASTE-WATER; AQUEOUS SAMPLES; ANALYTICAL METHODOLOGIES; LC/MS/MS ANALYSES; ION SUPPRESSION; ILLICIT DRUGS;
D O I
10.1016/j.talanta.2010.11.030
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Pharmaceuticals are emerging contaminants in surface water and they must be measured to follow their effects on the aquatic environment. We developed a solid-phase extraction and liquid chromatography-electrospray ionization tandem mass spectrometry (SPE-LC-ESI-MS/MS) method for the determination of twenty-six pharmaceutical compounds - which belong to antihypertensive and anti-ulcer agents - from surface water samples. The selection of pharmaceuticals was based on usage frequency in Hungary. During method development Oasis HLB, SampliQ Polymer SCX and Si-SCX SPE cartridges were tested. As LC eluent ammonium formate. ammonium acetate buffers at pH 3 and 5 were investigated and for quantitation both matrix-matched and internal standard calibration was used. For matrix effect assessment post-extraction spike method was applied which can separate the extraction efficiency from ion suppression for better determination of recovery. Method detection limits (MDLs) varied between 0.2 and 10 ng/L. Precision of the method, calculated as relative standard deviation (RSD), ranged from 0.2 to 14.6% and from 1.2 to 22.4% for intra- and inter-day analysis, respectively. The method was applied to analyze Danube water samples. Measured average concentrations varied between 2 and 39 ng/L for eleven compounds and another one could be detected under LOQ (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:1447 / 1454
页数:8
相关论文
共 50 条
  • [1] Determination of pharmaceuticals in wastewaters using solid-phase extraction-liquid chromatography-tandem mass spectrometry
    Gilart, Nuria
    Maria Marce, Rosa
    Borrull, Francesc
    Fontanals, Nuria
    JOURNAL OF SEPARATION SCIENCE, 2012, 35 (07) : 875 - 882
  • [2] Determination of several pesticides in water by solid-phase extraction, liquid chromatography and electrospray tandem mass spectrometry
    Rodrigues, Alexandre Mourao
    Ferreira, Vera
    Cardoso, Vitor Vale
    Ferreira, Elisabete
    Benoliel, Maria Joao
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1150 (1-2) : 267 - 278
  • [3] Identification of pesticides in water samples by solid-phase extraction and liquid chromatography-electrospray ionization mass spectrometry
    von Ameln Lovison, Otavio
    Jank, Louise
    de Souza, William Machado
    Ramalho Guerra, Rafaela
    Lamas, Alex Elias
    da Costa Ballestrin, Rogerio Antonio
    da Silva Morais Hein, Camila
    da Silva, Thaisla Cristiane Borella
    Corcao, Gertrudes
    Martins, Andreza Francisco
    WATER ENVIRONMENT RESEARCH, 2021, 93 (11) : 2670 - 2680
  • [4] Determination of antibiotics in aquatic environment by solid-phase extraction followed by liquid chromatography-electrospray ionization mass spectrometry
    Rao, R. Nageswara
    Venkateswarlu, N.
    Narsimha, R.
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1187 (1-2) : 151 - 164
  • [5] Simultaneous determination of various pharmaceutical compounds in water by solid-phase extraction-liquid chromatography-tandem mass spectrometry
    Zhang, Z. L.
    Zhou, J. L.
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1154 (1-2) : 205 - 213
  • [6] Rapid direct determination of pesticides and metabolites in environmental water samples at sub-μg/l level by on-line solid-phase extraction-liquid chromatography-electrospray tandem mass spectrometry
    Hernández, F
    Sancho, JV
    Pozo, O
    Lara, A
    Pitarch, E
    JOURNAL OF CHROMATOGRAPHY A, 2001, 939 (1-2) : 1 - 11
  • [7] Comparison of solid-phase extraction methods for the determination of azaspiracids in shellfish by liquid chromatography-electrospray mass spectrometry
    Moroney, C
    Lehane, M
    Braña-Magdalena, A
    Furey, A
    James, KJ
    JOURNAL OF CHROMATOGRAPHY A, 2002, 963 (1-2) : 353 - 361
  • [8] Determination of artificial sweeteners in water samples by solid-phase extraction and liquid chromatography-tandem mass spectrometry
    Ordonez, Edgar Y.
    Benito Quintana, Jose
    Rodil, Rosario
    Cela, Rafael
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1256 : 197 - 205
  • [9] Evaluation of strong cation-exchange polymers for the determination of drugs by solid-phase extraction-liquid chromatography-tandem mass spectrometry
    Fontanals, Nuria
    Miralles, Nuria
    Abdullah, Norhayati
    Davies, Arlene
    Gilart, Nuria
    Cormack, P. A. G.
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1343 : 55 - 62
  • [10] Determination of pharmaceutical compounds in surface- and ground-water samples by solid-phase extraction and high-performance liquid chromatography-electrospray ionization mass spectrometry
    Cahill, JD
    Furlong, ET
    Burkhardt, MR
    Kolpin, D
    Anderson, LG
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1041 (1-2) : 171 - 180