Multiphysics finite element modeling and validation of transient aerosol generation in an ultrasonic nebulizer drug delivery device

被引:3
作者
Smithmaitrie, P. [1 ]
Tangudomkit, K. [1 ]
机构
[1] Prince Songkla Univ, Fac Engn, Dept Mech Engn, Hat Yai 90112, Songkhla, Thailand
关键词
Ultrasonic nebulizer; Droplet generation; Finite element model; Piezoelectric actuator; Aerosol; Drug delivery; ATOMIZATION; FREQUENCY;
D O I
10.1016/j.jaerosci.2018.09.002
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The purpose of this research is to study the process of ultrasonic aerosol generation by finite element modeling and validate it by experimental method. This understanding leads to downsize nebulization droplets and improve the drug delivery effectiveness. The finite element model of an ultrasonic nebulizer consists of a cylindrical chamber (filled with liquid), air, and a piezoelectric actuator at the bottom of the chamber. Many physical interactions including piezoelectric structural vibration, pressure acoustic in fluid, two-phase flow and droplet separation are analyzed and simulated. In validation, the ultrasonic nebulizer is attached to Andersen cascade impactor (ACI) with a vacuum pump for classifying the aerosol droplet size. The inductively coupled plasma optical emission spectrometry (ICP-OES) technique is used to determine droplet size distribution. The simulation results have shown that the major distribution of droplet size is in a range of 1.64-2.70 mu m. Accordingly, the experimental results based on the ACI cutoff diameter stages depict that the major volume distribution of droplet size should be in a range of 1.10-3.29 mu m. Submicron droplets (0.56-0.90 mu m) are occurred in the simulation, and are also detected in the experiment at the ACI submicron cutoff diameters at 0.4 mu m and 0.7 mu m. This agreement has proved that the multiphysics model of the ultrasonic nebulizer can predict the size of generated aerosol. The relationship of ultrasonic nebulization parameters could be extended to conceive a new ultrasonic nebulizer design that would achieve submicron droplet size in rendering better drug delivery effectiveness.
引用
收藏
页码:110 / 121
页数:12
相关论文
共 26 条
[1]  
Al-Sueimani Y., 1999, P ILASS EUR
[2]   Nanoparticle Formulations in Pulmonary Drug Delivery [J].
Bailey, Mark M. ;
Berkland, Cory J. .
MEDICINAL RESEARCH REVIEWS, 2009, 29 (01) :196-212
[3]  
Barreras F, 2002, EXP FLUIDS, V33, P405, DOI [10.1007/S00348-002-0456-1, 10.1007/s00348-002-0456-1]
[4]  
COMSOL, 2011, COMSOL MULT US GUID, P55
[5]  
COMSOL, 2011, COMSOL MULT US GUID, P327
[6]  
COMSOL, 2011, COMSOL MULT US GUID, P460
[7]  
COMSOL, 2011, COMSOL MULT US GUID, P201
[8]  
Copley M., 2008, INHALATION, V2, P19
[9]   Practical design of ultrasonic spray devices: experimental testing of several atomizer geometries [J].
Dobre, M ;
Bolle, L .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2002, 26 (2-4) :205-211
[10]  
Dobre M., 1999, ILASS TOULOUSE FR