A re-assessment of nickel-doping method in iron isotope analysis on rock samples using multi-collector inductively coupled plasma mass spectrometry (vol 17, pg 891, 2020)

被引:0
作者
Gong, Hongmei [1 ,2 ]
Guo, Pengyuan [1 ,2 ,5 ]
Chen, Shuo [1 ,2 ]
Duan, Meng [1 ,2 ]
Sun, Pu [1 ,2 ]
Wang, Xiaohong [1 ,2 ]
Niu, Yaoling [1 ,2 ,3 ,4 ]
机构
[1] Chinese Acad Sci, Inst Oceanol, Key Lab Marine Geol & Environm, Qingdao 266071, Peoples R China
[2] Qingdao Natl Lab Marine Sci & Technol, Qingdao 266061, Peoples R China
[3] Univ Durham, Dept Earth Sci, Durham DH1 3LE, England
[4] China Univ Geosci, Sch Earth Sci & Resources, Beijing 100083, Peoples R China
[5] Chinese Acad Sci, Inst Oceanol, Nanhai Rd 7, Qingdao 266071, Shandong, Peoples R China
关键词
D O I
10.1007/s11631-020-00402-w
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
In the original publication, the vertical coordinate in Fig. 7 is incorrectly published as delta Fe-56 instead of delta Fe-57.
引用
收藏
页码:280 / 280
页数:1
相关论文
共 50 条
  • [21] Lead isotope measurement using a multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS)
    Choi, Hye-Bin
    Ryu, Jong-Sik
    Park, Sanghee
    Lee, Jeonghoon
    JOURNAL OF THE GEOLOGICAL SOCIETY OF KOREA, 2018, 54 (03) : 311 - 318
  • [22] Measurement of U and Pu isotope ratios in hair and nail samples using extraction chromatography and multi-collector inductively coupled plasma mass spectrometry
    Brown, J. N. W.
    Robertson, J. D.
    Brockman, J. D.
    TALANTA, 2014, 129 : 481 - 485
  • [23] Ultra-trace determination of plutonium in marine samples using multi-collector inductively coupled plasma mass spectrometry
    Lindahl, Patric
    Keith-Roach, Miranda
    Worsfold, Paul
    Choi, Min-Seok
    Shin, Hyung-Seon
    Lee, Sang-Hoon
    ANALYTICA CHIMICA ACTA, 2010, 671 (1-2) : 61 - 69
  • [24] The effect of matrix interferences on in situ boron isotope analysis by laser ablation multi-collector inductively coupled plasma mass spectrometry
    Standish, Christopher D.
    Chalk, Thomas B.
    Babila, Tali L.
    Milton, J. Andy
    Palmer, Martin R.
    Foster, Gavin L.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2019, 33 (10) : 959 - 968
  • [25] In situ calcium isotope analysis of Sr-rich carbonates using laser ablation multi-collector inductively coupled plasma mass spectrometry
    Jiang, Jiao
    Chen, Wei
    Lu, Jue
    Liu, Yonghong
    Li, Ming
    Sun, Jian
    Zhao, Kuidong
    Jiang, Shaoyong
    Liu, Yongsheng
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2025, 40 (04) : 975 - 988
  • [26] Hafnium isotope analysis of mixed standard solutions by multi-collector inductively coupled plasma mass spectrometry: an evaluation of isobaric interference corrections
    Choi M.S.
    Cheong C.-S.
    Kim J.
    Shin H.S.
    Journal of Analytical Science and Technology, 4 (1)
  • [27] High precision isotope ratio measurements of mercury isotopes in cinnabar ores using multi-collector inductively coupled plasma mass spectrometry
    Hintelmann, H
    Lu, SY
    ANALYST, 2003, 128 (06) : 635 - 639
  • [28] Comparison of factors affecting the accuracy of high-precision magnesium isotope analysis by multi-collector inductively coupled plasma mass spectrometry
    Teng, Fang-Zhen
    Yang, Wei
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2014, 28 (01) : 19 - 24
  • [29] Fit for purpose validated method for the determination of the strontium isotopic signature in mineral water samples by multi-collector inductively coupled plasma mass spectrometry
    Brach-Papa, Christophe
    Van Bocxstaele, Marleen
    Ponzevera, Emmanuel
    Quetel, Christophe R.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2009, 64 (03) : 229 - 234
  • [30] Assessment of matrix effects associated with Fe isotope analysis using 266 nm femtosecond and 193 nm nanosecond laser ablation multi-collector inductively coupled plasma mass spectrometry
    Zheng, Xin-Yuan
    Beard, Brian L.
    Johnson, Clark M.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (01) : 68 - 83