General Steps to Standardize the Laboratory Measurement of Serum Total 25-Hydroxyvitamin D

被引:52
|
作者
Sempos, Christopher T. [1 ]
Betz, Joseph M. [1 ]
Camara, Johanna E. [2 ]
Carter, Graham D. [3 ]
Cavalier, Etienne [4 ]
Clarke, Michael W. [5 ]
Dowling, Kirsten G. [6 ]
Durazo-Arvizu, Ramon A. [7 ]
Hoofnagle, Andrew N. [8 ]
Liu, Andy [9 ]
Phinney, Karen W. [10 ]
Sarafin, Kurtis [11 ]
Wise, Stephen A. [1 ,2 ]
Coates, Paul M. [1 ]
机构
[1] NIH, Off Dietary Supplements, Bldg 10, Bethesda, MD 20892 USA
[2] NIST, Chem Sci Div, Gaithersburg, MD 20899 USA
[3] Imperial Coll Healthcare NHS Trust, London, England
[4] Univ Liege, CHU Liege, Dept Clin Chem, Liege, Belgium
[5] Univ Western Australia, Ctr Microscopy Characterisat & Anal, Perth, WA 6009, Australia
[6] Univ Coll Cork, Sch Food & Nutr Sci, Cork Ctr Vitamin & Nutr Res D, Cork, Ireland
[7] Loyola Univ Chicago, Dept Publ Hlth Sci, Chicago, IL USA
[8] Univ Washington, Dept Lab Med, Seattle, WA 98195 USA
[9] Son Healthcare, Douglass Hanly Moir Pathol, Sydney, NSW, Australia
[10] NIST, Biomol Measurement Div, Gaithersburg, MD 20899 USA
[11] Hlth Canada, Nutr Res Div, Ottawa, ON, Canada
关键词
TANDEM MASS-SPECTROMETRY; VITAMIN-D METABOLITES; D-3;
D O I
10.5740/jaoacint.17-0259
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The Vitamin D Standardization Program (VDSP) has collaborated with numerous groups and agencies to assemble a set of tools, i.e., a reference measurement system, that can be used to establish the traceability of 25-hydroxyvitamin D [25(OH)D] assays to relevant reference measurement procedures and reference materials. This is done with the goal of verifying end-user laboratory performance using precise statistical criteria to determine whether a specific assay is standardized. The purpose of this paper was to outline a set of steps that routine clinical and research laboratories can use to standardize their 25(OH)D assays using these tools. These steps apply to laboratories using commercially developed immunoassay measurement systems as well as in-house assays, usually based on high HPLC or LC tandem MS measurement systems. The steps are (1) initial calibration, (2) initial assessment of accuracy and bias, (3) assessment of total percent CV and mean bias, (4) use of trueness controls, and (5) participation in accuracy-based performance testing and/or external quality assessment schemes. The goal of each laboratory assay is to have a total CV of <= 10% and mean bias of 55%. Rigorous and less rigorous but low-cost options for meeting these statistical criteria are provided. Research laboratories who infrequently measure 25(OH)D are advised to repeat steps 1-4 for every measurement cycle. For users of commercial immunoassays who have relatively little control over standardization, we present an option for using trueness controls to develop a master equation that can be used to standardize results to the reference methods.
引用
收藏
页码:1230 / 1233
页数:4
相关论文
共 50 条
  • [21] The recognition of 25-hydroxyvitamin D2 and D3 by a new binding protein based 25-hydroxyvitamin D assay
    Su, Zengliu
    Slay, Brian R.
    Carr, Randall
    Zhu, Yusheng
    CLINICA CHIMICA ACTA, 2013, 417 : 62 - 66
  • [22] 25-Hydroxyvitamin D Assays: The Quest For Accuracy
    Carter, Graham D.
    CLINICAL CHEMISTRY, 2009, 55 (07) : 1300 - 1302
  • [23] Measurement of plasma 25-hydroxyvitamin D2, 25-hydroxyvitamin D3 and 3-epi-25-hydroxyvitamin D3 in population of patients with cardiovascular disease by UPLC-MS/MS method
    Abouzid, Mohamed
    Karazniewicz-Lada, Marta
    Pawlak, Kornel
    Burchardt, Pawel
    Kruszyna, Lukasz
    Glowka, Franciszek
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2020, 1159
  • [24] A candidate reference measurement procedure for quantifying serum concentrations of 25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 using isotope-dilution liquid chromatography-tandem mass spectrometry
    Mineva, Ekaterina M.
    Schleicher, Rosemary L.
    Chaudhary-Webb, Madhulika
    Maw, Khin L.
    Botelho, Julianne C.
    Vesper, Hubert W.
    Pfeiffer, Christine M.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (19) : 5615 - 5624
  • [25] Is there an association between serum 25-hydroxyvitamin d concentrations and disease activity in rheumatoid arthritis?
    Baykal, T.
    Senel, K.
    Alp, F.
    Erdal, A.
    Ugur, M.
    BRATISLAVA MEDICAL JOURNAL-BRATISLAVSKE LEKARSKE LISTY, 2012, 113 (10): : 610 - 611
  • [26] Comparison of four current 25-hydroxyvitamin D assays
    Moon, Hee-Won
    Cho, Jin-Hee
    Hur, Mina
    Song, Junghan
    Oh, Gwi Young
    Park, Chul Min
    Yun, Yeo-Min
    Kim, Jin Q.
    CLINICAL BIOCHEMISTRY, 2012, 45 (4-5) : 326 - 330
  • [27] Accuracy of 25-Hydroxyvitamin D Assays: Confronting the Issues
    Carter, Graham D.
    CURRENT DRUG TARGETS, 2011, 12 (01) : 19 - 28
  • [28] Performance evaluation of two immunoassays for 25-hydroxyvitamin D
    Li, Lusha
    Zeng, Qin
    Yuan, Jingjing
    Xie, Zhongjian
    JOURNAL OF CLINICAL BIOCHEMISTRY AND NUTRITION, 2016, 58 (03) : 186 - 192
  • [29] Analytical variation concerning total 25-hydroxyvitamin D measurement, where are we now? A DEQAS review of current assay performance
    Briggs, L. E.
    Whitewood, J. K.
    Williams, E. L.
    JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 2023, 231
  • [30] Quantitation of 25-hydroxyvitamin D2 and D3 in serum and plasma by LCMS/MS
    Lee, Dayong
    Garrett, Timothy J.
    Goldberger, Bruce A.
    Bazydlo, Lindsay A. L.
    BIOANALYSIS, 2015, 7 (02) : 167 - 178