Two custom-made In0.5Ga0.5P p(+)-i-n(+) circular mesa spectroscopic X-ray photodiodes with different diameters (200 mu m and 400 mu m) and a 5 mu m i layer have been characterized for their response to X-ray photons within the energy range 4.95 keV to 21.17 keV. The photodiodes, operating uncooled at 30 degrees C, were coupled, in turn, to the same custom-made charge-sensitive preamplifier. X-ray fluorescence spectra of high-purity calibration foils excited by a Mo target X-ray tube were accumulated. The energy resolution (Full Width at Half Maximum) increased from 0.79 +/- 0.02 keV at 4.95 keV to 0.83 +/- 0.02 keV at 21.17 keV, and from 1.12 +/- 0.02 keV at 4.95 keV to 1.15 +/- 0.02 keV at 21.17 keV, when using the 200 mu m and 400 mu m diameter devices, respectively. Energy resolution broadening with increasing energy was attributed to increasing Fano noise (negligible incomplete charge collection noise was suggested); for the first time, the Fano factor for In0.5Ga0.5P was experimentally determined to be 0.13, suggesting a Fano limited energy resolution of 145 eV at 5.9 keV. The charge output of each system had a linear relationship with photon energy, across the investigated energy range. The count rate of both spectroscopic systems increased linearly with varying X-ray tube current up to similar to 10(5) photons s(-1) cm(-2) incident photon fluences. The development of In0.5Ga0.5P based spectrometers is particularly important for hard X/gamma-ray astronomy, due to the material's large linear X-ray and gamma-ray absorption coefficients and the ability to operate uncooled at high temperatures. Published by AIP Publishing.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Characterization of Japanese color sticks by energy dispersive X-ray fluorescence, X-ray diffraction and Fourier transform infrared analysis
    Manso, M.
    Valadas, S.
    Pessanha, S.
    Guilherme, A.
    Queralt, I.
    Candeias, A. E.
    Carvalho, M. L.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2010, 65 (04) : 321 - 327
  • [32] Performance of an energy resolving X-ray pixel detector
    Bates, R
    Derbyshire, G
    Gannon, WJF
    Iles, G
    Lowe, B
    Mathieson, K
    Passmore, MS
    Prydderch, M
    Seller, P
    Smith, K
    Thomas, SL
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 477 (1-3) : 161 - 165
  • [33] Arrays of silicon drift detectors for an extraterrestrial X-ray spectrometer
    Rehak, Pavel
    Carini, Gabriella
    Chen, Wei
    De Geronimo, Gianluigi
    Fried, Jack
    Li, Zheng
    Pinelli, Donald A.
    Siddons, D. Peter
    Vernon, Emerson
    Gaskin, Jessica A.
    Ramsey, Brian D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 624 (02) : 260 - 264
  • [34] Superconducting tunnel junction detectors for soft X-ray astrophysics
    Verhoeve, P.
    Hijmering, R. A.
    Martin, D. D. E.
    Jerjen, I.
    Peacock, A.
    Venn, R.
    HIGH ENERGY, OPTICAL, AND INFRARED DETECTORS FOR ASTRONOMY II, 2006, 6276
  • [35] Thin transmission photodiodes as monitor detectors in the X-ray range
    Krumrey, Michael
    Gerlach, Martin
    Hoffmann, Michael
    Mueller, Peter
    SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 1145 - +
  • [36] Quantitative Comparisons of Image Quality for Flash X-Ray Detectors
    Wilson, F.
    Harke, K.
    Hardy, A. J.
    Kline, D. J.
    Sullivan, K. T.
    Tringe, J.
    Frick, C. P.
    Eliasson, V.
    EXPERIMENTAL TECHNIQUES, 2025,
  • [37] Indirect X-ray detectors with single-photon sensitivity
    Pauwels, Kristof
    Douissard, Paul-Antoine
    JOURNAL OF SYNCHROTRON RADIATION, 2022, 29 (06) : 1394 - 1406
  • [38] Diamond Detectors for Radiotherapy X-Ray Small Beam Dosimetry
    Talamonti, C.
    Kanxheri, K.
    Pallotta, S.
    Servoli, L.
    FRONTIERS IN PHYSICS, 2021, 9
  • [39] Characterization of large area avalanche photodiodes in X-ray and VUV-light detection
    Fernandes, L. M. P.
    Amaro, F. D.
    Antognini, A.
    Cardoso, J. M. R.
    Conde, C. A. N.
    Huot, O.
    Knowles, P. E.
    Kottmann, F.
    Lopes, J. A. M.
    Ludhova, L.
    Monteiro, C. M. B.
    Mulhauser, F.
    Pohl, R.
    dos Santos, J. M. F.
    Schaller, L. A.
    Taqqu, D.
    Veloso, J. F. C. A.
    JOURNAL OF INSTRUMENTATION, 2007, 2
  • [40] Superlattice-enhanced silicon soft X-ray and charged particle detectors with nanosecond time response
    Looker, Q.
    Aguirre, B. A.
    Hoenk, M. E.
    Jewell, A. D.
    Sanchez, M. O.
    Tierney, B. D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 916 : 148 - 153