Hollow-fibre liquid-phase microextraction and gas chromatography-mass spectrometric determination of amphetamines in whole blood

被引:22
作者
Bombana, Henrique Silva [1 ]
dos Santos, Marcelo Filonzi [1 ]
Munoz, Daniel Romero [1 ]
Leyton, Vilma [1 ]
机构
[1] Univ Sao Paulo, Fac Med, Av Dr Arnaldo,455 Cerqueira Cesar, BR-01246903 Sao Paulo, Brazil
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2020年 / 1139卷
基金
巴西圣保罗研究基金会;
关键词
Amphetamines; Liquid-phase microextraction; Green chemistry; STIMULANTS; HAIR; METHAMPHETAMINE; METABOLITES; COCAINE; URINE; DRUGS; MDMA;
D O I
10.1016/j.jchromb.2020.121973
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Here, we present a fully validated method using a hollow-fibre liquid-phase microextraction technique for the determination by gas chromatography-mass spectrometry (GC-MS) of amphetamine (AMP), methamphetamine (MET), fenproporex (FEN), 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyamphetamine (MDA) and 3,4-methylenedioxyethylamphetamine (MDEA) in whole blood. The validation parameters presented successful values within those recommended by the Scientific Working Group for Forensic Toxicology (SWGTox) in the Standard Practices for Method Validation in Forensic Toxicology. The limits of detection ranged from 1 to 3 ng/mL, and the limits of quantification ranged from 2 to 5 ng/mL. The determination coefficients (r(2)) ranged from 0.990 to 0.997, and the method presented good intraday and interday accuracy (from 90.4% to 97.2%) and satisfactory recovery (from 68% to 110%). No carryover was observed. The heteroscedasticity was tested, and only AMP presented homoscedasticity. Weighting factors were applied to correct the linearity of MET (1/x(2)), MDA (1/x), FEN (1/x(1/2)), MDMA (1/x(2)) and MDEA (1/y). Dilution integrity was tested at ratios of 1:2, 1:5 and 1:10, and all maintained intraday precision (from 94.9% to 99.3%) and interday precision (from 89.4% to 94.9%). The validated method was applied to six real whole blood samples from individuals suspected of consuming ecstasy, and MDMA, MDA and amphetamine were successfully identified and quantified.
引用
收藏
页数:6
相关论文
共 50 条
[41]   High-Throughput Determination of Nicotine in Plasma by Ultrasonication Enhanced Hollow Fiber Liquid-Phase Microextraction Prior to Gas Chromatography [J].
Liu, Xiaotian ;
Liang, Shumei ;
Pan, Jie ;
Guo, Yugao ;
Luo, Huiru ;
Zhao, Qingsong ;
Guan, Shan .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2014, 52 (06) :553-558
[42]   Supported Liquid Membranes for Hollow-Fibre Based Microextraction and Voltammetric Determination of Neuroblastoma Biomarkers [J].
Hrdlicka, Vojtech ;
Barek, Jiri ;
Navratil, Tomas .
PROCEEDINGS OF THE INTERNATIONAL CONFERENCE MODERN ELECTROCHEMICAL METHODS XXXVIII, 2018, :81-84
[43]   Simultaneous Determination of HFBA-Derivatized Amphetamines and Ketamines in Urine by Gas Chromatography-Mass Spectrometry [J].
Lee, Hei Hwa ;
Lee, Jong Feng ;
Lin, Sin Yu ;
Chen, Ping Ho ;
Chen, Bai Hsiun .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2011, 35 (03) :162-169
[44]   Hollow fibre liquid-phase microextraction of functionalised carboxylic acids from atmospheric particles combined with capillary electrophoresis/mass spectrometric analysis [J].
van Pinxteren, D. ;
Teich, M. ;
Herrmann, H. .
JOURNAL OF CHROMATOGRAPHY A, 2012, 1267 :178-188
[45]   Dispersive liquid-phase microextraction procedure for spectrometric determination of cadmium [J].
Kocurova, Livia ;
Balogh, Ioseph S. ;
Andruch, Vasil .
MICROCHEMICAL JOURNAL, 2013, 107 :3-9
[46]   Application of dynarnic liquid-phase microextraction and injection port derivatization combined with gas chromatography-mass spectrometry to the determination of acidic pharmaceutically active compounds in water samples [J].
Zhang, Jie ;
Lee, Hian Kee .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (44) :7527-7532
[47]   Determination of Amphetamines in Human Hair Using Dynamic Liquid-Phase Microextraction and Gas Chromatography/Selected Ion Monitoring-Mass Spectrometry After Microwave Derivatization [J].
Zhu Dan ;
Meng Pinjia ;
He Hongyuan .
CHINESE JOURNAL OF CHROMATOGRAPHY, 2007, 25 (01) :16-20
[48]   Solid phase microextraction combined with gas chromatography-mass spectrometry for the determination of diquat residues in water [J].
Gao, Lina ;
Liu, Guojie ;
Zhu, Juan ;
Wang, Chunyuan ;
Liu, Junting .
JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 70 (05) :552-557
[49]   Hollow fibre liquid-phase microextraction of parabens from environmental waters [J].
Diaz-Alvarez, Myriam ;
Turiel, Esther ;
Martin-Esteban, Antonio .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2013, 93 (07) :727-738
[50]   Determination of opiates in whole blood using microextraction by packed sorbent and gas chromatography-tandem mass spectrometry [J].
Prata, Margarida ;
Ribeiro, Andreia ;
Figueirinha, David ;
Rosado, Tiago ;
Oppolzer, David ;
Restolho, Jose ;
Araujo, Andre R. T. S. ;
Costa, Suzel ;
Barroso, Mario ;
Gallardo, Eugenia .
JOURNAL OF CHROMATOGRAPHY A, 2019, 1602 :1-10