Hollow-fibre liquid-phase microextraction and gas chromatography-mass spectrometric determination of amphetamines in whole blood

被引:21
作者
Bombana, Henrique Silva [1 ]
dos Santos, Marcelo Filonzi [1 ]
Munoz, Daniel Romero [1 ]
Leyton, Vilma [1 ]
机构
[1] Univ Sao Paulo, Fac Med, Av Dr Arnaldo,455 Cerqueira Cesar, BR-01246903 Sao Paulo, Brazil
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2020年 / 1139卷
基金
巴西圣保罗研究基金会;
关键词
Amphetamines; Liquid-phase microextraction; Green chemistry; STIMULANTS; HAIR; METHAMPHETAMINE; METABOLITES; COCAINE; URINE; DRUGS; MDMA;
D O I
10.1016/j.jchromb.2020.121973
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Here, we present a fully validated method using a hollow-fibre liquid-phase microextraction technique for the determination by gas chromatography-mass spectrometry (GC-MS) of amphetamine (AMP), methamphetamine (MET), fenproporex (FEN), 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyamphetamine (MDA) and 3,4-methylenedioxyethylamphetamine (MDEA) in whole blood. The validation parameters presented successful values within those recommended by the Scientific Working Group for Forensic Toxicology (SWGTox) in the Standard Practices for Method Validation in Forensic Toxicology. The limits of detection ranged from 1 to 3 ng/mL, and the limits of quantification ranged from 2 to 5 ng/mL. The determination coefficients (r(2)) ranged from 0.990 to 0.997, and the method presented good intraday and interday accuracy (from 90.4% to 97.2%) and satisfactory recovery (from 68% to 110%). No carryover was observed. The heteroscedasticity was tested, and only AMP presented homoscedasticity. Weighting factors were applied to correct the linearity of MET (1/x(2)), MDA (1/x), FEN (1/x(1/2)), MDMA (1/x(2)) and MDEA (1/y). Dilution integrity was tested at ratios of 1:2, 1:5 and 1:10, and all maintained intraday precision (from 94.9% to 99.3%) and interday precision (from 89.4% to 94.9%). The validated method was applied to six real whole blood samples from individuals suspected of consuming ecstasy, and MDMA, MDA and amphetamine were successfully identified and quantified.
引用
收藏
页数:6
相关论文
共 50 条
  • [11] Simultaneous quantification of amphetamines, caffeine and ketamine in urine by hollow fiber liquid phase microextraction combined with gas chromatography-flame ionization detector
    Xiong, Jun
    Chen, Jie
    He, Man
    Hu, Bin
    [J]. TALANTA, 2010, 82 (03) : 969 - 975
  • [12] Determination of organic micropollutants in rainwater using hollow fiber membrane/liquid-phase microextraction combined with gas chromatography-mass spectrometry
    Basheer, C
    Balasubramanian, R
    Lee, HK
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2003, 1016 (01) : 11 - 20
  • [13] Determination of alkaloids in Corydalis yanhusuo using hollow-fibre liquid phase microextraction and high performance liquid chromatography
    Huawei Lu
    Huanquan Sun
    Xia Liu
    Shengxiang Jiang
    [J]. Chemical Papers, 2009, 63 : 351 - 357
  • [14] Simple and rapid analysis of four amphetamines in human whole blood and urine using liquid-liquid extraction without evaporation/derivatization and gas chromatography-mass spectrometry
    Guo, Lin
    Lin, Zebin
    Huang, Zhibin
    Liang, Hao
    Jiang, Yan
    Ye, Yonghong
    Wu, Zongping
    Zhang, Runsheng
    Zhang, Yurong
    Rao, Yulan
    [J]. FORENSIC TOXICOLOGY, 2015, 33 (01) : 104 - 111
  • [15] Determination of Barbiturates in Biological Specimens by Flat Membrane-Based Liquid-Phase Microextraction and Liquid Chromatography-Mass Spectrometry
    Zhu, Ruiqin
    Dong, Ying
    Cai, Xiangyang
    Huang, Chuixiu
    [J]. MOLECULES, 2019, 24 (08)
  • [16] Miniaturized hollow fibre assisted liquid-phase microextraction and gas chromatography for determination of trace concentration of sufentanil and alfentanil in biological samples
    Fakhari, Ali Reza
    Tabani, Hadi
    Nojavan, Saeed
    [J]. DRUG TESTING AND ANALYSIS, 2013, 5 (07) : 589 - 595
  • [17] Miniaturized hollow fiber assisted liquid-phase microextraction and gas chromatography-mass spectrometry for determination of benzophenone and derivates in human urine sample
    Kawaguchi, Migaku
    Ito, Rie
    Honda, Hidehiro
    Koganei, Youji
    Okanouchi, Noriya
    Saito, Koichi
    Seto, Yasuo
    Nakazawa, Hiroyuki
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (03): : 298 - 302
  • [18] Automated hollow fiber-protected dynamic liquid-phase microextraction of pesticides for gas chromatography - Mass spectrometric analysis
    Hou, L
    Shen, G
    Lee, HK
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2003, 985 (1-2) : 107 - 116
  • [19] Hollow-fibre liquid-phase microextraction: A simple and fast cleanup step used for PAHs determination in pine needles
    Ratola, Nuno
    Alves, Arminda
    Kalogerakis, Nicolas
    Psillakis, Elefteria
    [J]. ANALYTICA CHIMICA ACTA, 2008, 618 (01) : 70 - 78
  • [20] Determination of low levels of benzodiazepines and their metabolites in urine by hollow-fiber liquid-phase microextraction (LPME) and gas chromatography-mass spectrometry (GC-MS)
    de Bairros, Andre Valle
    de Almeida, Rafael Menck
    Pantaleao, Lorena
    Barcellos, Thiago
    Moura e Silva, Sidnei
    Yonamine, Mauricio
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 975 : 24 - 33