Quantification of seminolipid by LC-ESI-MS/MS-multiple reaction monitoring: compensatory levels in Cgt+/- mice

被引:12
作者
Kongmanas, Kessiri [1 ,2 ]
Xu, Hongbin [1 ,2 ]
Yaghoubian, Arman [6 ]
Franchini, Laura [4 ]
Panza, Luigi [5 ]
Ronchetti, Fiamma [4 ]
Faull, Kym [6 ]
Tanphaichitr, Nongnuj [1 ,2 ,3 ]
机构
[1] Ottawa Hosp Res Inst, Chron Dis Program, Ottawa, ON, Canada
[2] Univ Ottawa, Fac Med, Dept Biochem Microbiol Immunol, Ottawa, ON, Canada
[3] Univ Ottawa, Fac Med, Dept Obstet Gynecol, Ottawa, ON, Canada
[4] Univ Milan, Dipartimento Chim, Milan, Italy
[5] Univ Piemonte Orientale, Dipartimento Sci Chim, Novara, Italy
[6] Univ Calif Los Angeles, David Geffen Sch Med, NPI Semel Inst Neurosci & Human Behav, Pasarow Mass Spectrometry Lab, Los Angeles, CA 90095 USA
基金
加拿大健康研究院;
关键词
liquid chromatography; electrospray ionization; tandem mass spectrometry; ZONA-PELLUCIDA BINDING; GALACTOSE-CERAMIDE GALACTOSYLTRANSFERASE; SPERM SURFACE ARYLSULFATASE; MOUSE SPERM; MASS-SPECTROMETRY; DEFICIENT MICE; LIPID RAFTS; PLASMA-MEMBRANE; SULFOGLYCOLIPIDS; SULFATIDE;
D O I
10.1194/jlr.D010116
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Seminolipid, also known as sulfogalactosylglycerolipid (SGG), plays important roles in male reproduction. Therefore, an accurate and sensitive method for SGG quantification in testes and sperm is needed. Here we compare SGG quantitation by the traditional colorimetric Azure A assay with LC-ESI-MS/MS using multiple reaction monitoring (MRM). Inclusion of deuterated SGG as the internal standard endowed accuracy to the MRM method. The results showed reasonable agreement between the two procedures for purified samples, but for crude lipid extracts, the colorimetric assay significantly overestimated the SGG content. Using ESI-MS/MS MRM, C16:0-alkyl/C16:0-acyl SGG of Cgt(+/-) mice was quantified to be 406.06 +/- 23.63 mu g/g testis and 0.13 +/- 0.02 mu g/million sperm, corresponding to 78% and 87% of the wild-type values, respectively. CGT (ceramide galactosyltransferase) is a critical enzyme in the SGG biosynthesis pathway. Cgt(-/-) males depleted of SGG are infertile due to spermatogenesis arrest. However, Cgt(+/-) males sire offspring.jlr The higher than 50% expression level of SGG in Cgt(+/-) animals, compared with the wild-type expression, might be partly due to compensatory translation of the active CGT enzyme. The results also indicated that 78% of SGG levels in Cgt(+/-) mice were sufficient for normal spermatogenesis.-Kongmanas, K., H. Xu, A. Yaghoubian, L. Franchini, L. Panza, F. Ronchetti, K. Faull, and N. Tanphaichitr. Quantification of seminolipid by LC-ESI-MS/MS-multiple reaction monitoring: compensatory levels in Cgt(+/-) mice. J. Lipid Res. 2010. 51: 3548-3558.
引用
收藏
页码:3548 / 3558
页数:11
相关论文
共 50 条
  • [1] Isotope dilution LC-ESI-MS/MS and low resolution selected reaction monitoring as a tool for the accurate quantification of urinary testosterone
    Ereno Artabe, Amaia
    Gonzalez-Gago, Adriana
    Suarez Fernandez, Amanda
    Pitarch Motellon, Jorge
    Roig-Navarro, Antoni F.
    Pozo, Oscar J.
    Rodriguez-Gonzalez, Pablo
    Garcia Alonso, J. Ignacio
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 163 : 113 - 121
  • [2] Highly sensitive quantification of key regulatory oxysterols in biological samples by LC-ESI-MS/MS
    Honda, Akira
    Yamashita, Kouwa
    Hara, Takashi
    Ikegami, Tadashi
    Miyazaki, Teruo
    Shirai, Mutsumi
    Xu, Guorong
    Numazawa, Mitsuteru
    Matsuzaki, Yasushi
    JOURNAL OF LIPID RESEARCH, 2009, 50 (02) : 350 - 357
  • [3] LC-ESI-MS/MS method for the accurate quantification of eight nitrosamines in pharmaceutical products
    Danis, Ibrahim
    Unal, Durisehvar Ozer
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2025,
  • [4] Quantification of desloratadine in human plasma by LC-ESI-MS/MS and application to a pharmacokinetic study
    Venkata Suresh Ponnuru
    B.R. Challa
    Ramarao Nadendla
    Journal of Pharmaceutical Analysis, 2012, 2 (03) : 180 - 187
  • [5] Simultaneous quantification of ten cytotoxic drugs by a validated LC-ESI-MS/MS method
    Nussbaumer, Susanne
    Fleury-Souverain, Sandrine
    Antinori, Paola
    Sadeghipour, Farshid
    Hochstrasser, Denis F.
    Bonnabry, Pascal
    Veuthey, Jean-Luc
    Geiser, Laurent
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 398 (7-8) : 3033 - 3042
  • [6] Quantification of desloratadine in human plasma by LC-ESI-MS/MS and application to a pharmacokinetic study
    Ponnuru, Venkata Suresh
    Challa, B. R.
    Nadendla, Ramararo
    JOURNAL OF PHARMACEUTICAL ANALYSIS, 2012, 2 (03) : 180 - 187
  • [7] Development and validation of a rapid LC-ESI-MS/MS method for quantification of fluoxetine and its application to MS binding assays
    Hess, Marielle
    Hoefner, Georg
    Wanner, Klaus Theodor
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 400 (10) : 3505 - 3515
  • [8] LC-ESI-MS/MS method for the quantification of entecavir in human plasma and its application to bioequivalence study
    Challa, Balasekhara Reddy
    Awen, Bahlul Z.
    Chandu, Babu Rao
    Rihanaparveen, Shaik
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (11-12): : 769 - 776
  • [9] LC-ESI-MS/MS quantification of 4β-hydroxycholesterol and cholesterol in plasma samples of limited volume
    Xu, Yaodong
    Yuan, Yang
    Smith, Lisa
    Edom, Rick
    Weng, Naidong
    Mamidi, Rao
    Silva, Jose
    Evans, David C.
    Lim, Heng-Keang
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2013, 85 : 145 - 154
  • [10] Novel Matrix Normalization Technique for Accurate LC-ESI-MS/MS Detection and Quantification of Drugs and Their Metabolites in Toxicology Research and Practice
    Rosano, Thomas G.
    Rumberger, John M.
    Scholz, Kiley L.
    Konetchy Jr, Robert M.
    Wood, Michelle
    CURRENT PROTOCOLS, 2023, 3 (01):