Flow Velocity Measurement Using a Spatial Averaging Method with Two-Dimensional Flexural Ultrasonic Array Technology

被引:13
|
作者
Kang, Lei [1 ]
Feeney, Andrew [1 ]
Su, Riliang [2 ]
Lines, David [2 ]
Ramadas, Sivaram Nishal [3 ]
Rowlands, George [1 ]
Dixon, Steve [1 ]
机构
[1] Univ Warwick, Dept Phys, Coventry CV4 7AL, W Midlands, England
[2] Univ Strathclyde, Dept Elect & Elect Engn, Glasgow G1 1XW, Lanark, Scotland
[3] Honeywell, Reddidtch B98 9ND, England
基金
英国工程与自然科学研究理事会;
关键词
transit-time ultrasonic flow measurement; flow velocity; spatial averaging; flexural ultrasonic array transducer; DATA INTEGRATION; PROFILE; TOMOGRAPHY; FLOWMETERS; SIMULATION; METER;
D O I
10.3390/s19214786
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Accurate average flow velocity determination is essential for flow measurement in many industries, including automotive, chemical, and oil and gas. The ultrasonic transit-time method is common for average flow velocity measurement, but current limitations restrict measurement accuracy, including fluid dynamic effects from unavoidable phenomena such as turbulence, swirls or vortices, and systematic flow meter errors in calibration or configuration. A new spatial averaging method is proposed, based on flexural ultrasonic array transducer technology, to improve measurement accuracy and reduce the uncertainty of the measurement results. A novel two-dimensional flexural ultrasonic array transducer is developed to validate this measurement method, comprising eight individual elements, each forming distinct paths to a single ultrasonic transducer. These paths are distributed in two chordal planes, symmetric and adjacent to a diametral plane. It is demonstrated that the root-mean-square deviation of the average flow velocity, computed using the spatial averaging method with the array transducer is 2.94%, which is lower compared to that of the individual paths ranging from 3.65% to 8.87% with an average of 6.90%. This is advantageous for improving the accuracy and reducing the uncertainty of classical single-path ultrasonic flow meters, and also for conventional multi-path ultrasonic flow meters through the measurement via each flow plane with reduced uncertainty. This research will drive new developments in ultrasonic flow measurement in a wide range of industrial applications.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Fabrication and Spatial Focusing of a Stretchable Two-dimensional Ultrasonic Array Based on Row and Column Electrodes
    Liu, Wei
    Wu, Dawei
    Zhu, Chunling
    INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS 2021), 2021,
  • [22] Two-dimensional distribution measurement of in-plane velocity component using bias-frequency spatial encoding
    Maru, Koichi
    Hashimoto, Yuji
    Abd Ghafar, Sayyidatul N. A. B.
    OPTICAL ENGINEERING, 2021, 60 (03)
  • [23] Two-dimensional flow visualization and velocity measurement in natural convection near indoor heated surfaces using a thermal image velocimetry method
    Wu, Qing
    Zhu, Chang-an
    Liu, Lin
    Liu, Jing
    Luo, Zhiwen
    APPLIED THERMAL ENGINEERING, 2019, 146 : 556 - 568
  • [24] Velocity Measurement for flow particles by Using Spatial Filtering Technique Based on Sensor Array
    Lu, Zengxi
    Yang, Gang
    Wang, Zengshuang
    MEASUREMENT AND CONTROL OF GRANULAR MATERIALS, 2012, 508 : 263 - 266
  • [25] Optical method for two-dimensional ultrasonic detection
    Paltauf, G
    Schmidt-Kloiber, H
    Köstli, KP
    Frenz, M
    APPLIED PHYSICS LETTERS, 1999, 75 (08) : 1048 - 1050
  • [26] Stroboscopic two-dimensional ultrasonic velocity profiling for measuring flow transition in Taylor Couette systems
    Pokorny, Lea
    Kohler, Lucas
    Takeda, Yasushi
    Windhab, Erich J.
    FLOW MEASUREMENT AND INSTRUMENTATION, 2016, 52 : 137 - 143
  • [27] Measuring spatial coherence with a two-dimensional aperture array
    Gonzalez, Aura I.
    Mejia, Yobani
    RIAO/OPTILAS 2007, 2008, 992 : 478 - 483
  • [28] FLOW MEASUREMENT USING ULTRASONIC METHOD
    MULTON, F
    HOUILLE BLANCHE-REVUE INTERNATIONALE DE L EAU, 1994, 49 (07): : 30 - 35
  • [29] Application of ultrasonic doppler method for bubbly flow measurement using two ultrasonic frequencies
    Murakawa, H
    Kikura, H
    Aritomi, M
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2005, 29 (07) : 843 - 850
  • [30] Flow Velocity Measurement Using Spatial Filter
    韩兵
    佟允宪
    李军
    清华大学学报(自然科学版), 1996, (12) : 73 - 78