Flow Velocity Measurement Using a Spatial Averaging Method with Two-Dimensional Flexural Ultrasonic Array Technology

被引:13
|
作者
Kang, Lei [1 ]
Feeney, Andrew [1 ]
Su, Riliang [2 ]
Lines, David [2 ]
Ramadas, Sivaram Nishal [3 ]
Rowlands, George [1 ]
Dixon, Steve [1 ]
机构
[1] Univ Warwick, Dept Phys, Coventry CV4 7AL, W Midlands, England
[2] Univ Strathclyde, Dept Elect & Elect Engn, Glasgow G1 1XW, Lanark, Scotland
[3] Honeywell, Reddidtch B98 9ND, England
基金
英国工程与自然科学研究理事会;
关键词
transit-time ultrasonic flow measurement; flow velocity; spatial averaging; flexural ultrasonic array transducer; DATA INTEGRATION; PROFILE; TOMOGRAPHY; FLOWMETERS; SIMULATION; METER;
D O I
10.3390/s19214786
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Accurate average flow velocity determination is essential for flow measurement in many industries, including automotive, chemical, and oil and gas. The ultrasonic transit-time method is common for average flow velocity measurement, but current limitations restrict measurement accuracy, including fluid dynamic effects from unavoidable phenomena such as turbulence, swirls or vortices, and systematic flow meter errors in calibration or configuration. A new spatial averaging method is proposed, based on flexural ultrasonic array transducer technology, to improve measurement accuracy and reduce the uncertainty of the measurement results. A novel two-dimensional flexural ultrasonic array transducer is developed to validate this measurement method, comprising eight individual elements, each forming distinct paths to a single ultrasonic transducer. These paths are distributed in two chordal planes, symmetric and adjacent to a diametral plane. It is demonstrated that the root-mean-square deviation of the average flow velocity, computed using the spatial averaging method with the array transducer is 2.94%, which is lower compared to that of the individual paths ranging from 3.65% to 8.87% with an average of 6.90%. This is advantageous for improving the accuracy and reducing the uncertainty of classical single-path ultrasonic flow meters, and also for conventional multi-path ultrasonic flow meters through the measurement via each flow plane with reduced uncertainty. This research will drive new developments in ultrasonic flow measurement in a wide range of industrial applications.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Two-Dimensional Flexural Ultrasonic Phased Array for Flow Measurement
    Kang, Lei
    Feeney, Andrew
    Su, Riliang
    Lines, David
    Jaeger, Axel
    Wang, Han
    Arnaudov, Yavor
    Ramadas, Sivaram Nishal
    Kupnik, Mario
    Dixon, Steve
    2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [2] Measurement of two-dimensional vector velocity using spatial filtering technique
    Li, P
    Ma, BM
    Zhang, BR
    Qu, XM
    AUTOMATED OPTICAL INSPECTION FOR INDUSTRY: THEORY, TECHNOLOGY, AND APPLICATIONS II, 1998, 3558 : 394 - 396
  • [3] Study of Estimation Method for Unsteady Inflow Velocity in Two-Dimensional Ultrasonic-Measurement-Integrated Blood Flow Simulation
    Kadowaki, Hiroko
    Hayase, Toshiyuki
    Funamoto, Kenichi
    Taniguchi, Nobuyuki
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2016, 63 (02) : 403 - 414
  • [4] Voluntary averaging of two-dimensional spatial position
    Bossi, M.
    Dakin, S. C.
    PERCEPTION, 2014, 43 (01) : 43 - 43
  • [5] Two-Dimensional Automatic Measurement for Nozzle Flow Distribution Using Improved Ultrasonic Sensor
    Zhai, Changyuan
    Zhao, Chunjiang
    Wang, Xiu
    Wang, Ning
    Zou, Wei
    Li, Wei
    SENSORS, 2015, 15 (10) : 26353 - 26367
  • [6] Simultaneous measurement of two-dimensional velocity and direction of liquid flow by cross-correlation method
    Hashiba, N
    Kojima, E
    JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1996, 29 (04) : 577 - 581
  • [7] METHOD OF AVERAGING FOR TWO-DIMENSIONAL INTEGRABLE EQUATIONS
    KRICHEVER, IM
    FUNCTIONAL ANALYSIS AND ITS APPLICATIONS, 1988, 22 (03) : 200 - 213
  • [8] Preliminary Study on Measurement of Two-dimensional Vortex Flow Field Based on Ultrasonic Doppler Velocimetry Method
    Huang S.
    Zhu Z.
    Huang W.
    He J.
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2018, 52 (08): : 1415 - 1422
  • [9] Temporal averaging of two-dimensional correlation functions for velocity vector imaging of cardiac blood flow
    Takahashi, Hiroki
    Hasegawa, Hideyuki
    Kanai, Hiroshi
    JOURNAL OF MEDICAL ULTRASONICS, 2015, 42 (03) : 323 - 330
  • [10] Two-dimensional spatial coherence measurement of X-ray sources using aperture array mask
    Li, Qingcheng
    Lu, Yili
    Lu, Yonghua
    Wang, Pei
    OPTICS EXPRESS, 2023, 31 (22) : 36304 - 36313