SCADA data based realistic simulation framework to evaluate environmental impact on performance of wind turbine condition monitoring systems

被引:0
|
作者
Aziz, Usama [1 ,2 ]
Charbonnier, Sylvie [1 ]
Berenguer, Christophe [1 ]
Lebranchu, Alexis [2 ]
Prevost, Frederic [2 ]
机构
[1] Univ Grenoble Alpes, CNRS, Grenoble INP, GIPSA Lab, F-38000 Grenoble, France
[2] Valemo SAS, F-33323 Begles, France
关键词
MODELS;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Wind turbines are an integral part of renewable energy based power generation targets all over the world. With expanding fleets, varying geographical locations, improving technologies, competitive markets and a variety of manufactures to choose from, wind farm operators often end up with heterogeneous fleets. This paper presents a methodology to comprehensively evaluate the performance of fault indicators for wind turbines condition monitoring using power curves. A comprehensive analysis is done by taking into account various factors that can influence performance indicators such as the differences between the geographical locations of the wind farms and multiple fault signatures. A controlled and realistic simulation framework is presented and used to create a database covering multiple wind farms from different geographical conditions having distinct environmental profiles. Realistic fault signatures are used for condition monitoring and performance analysis using two fault detection approaches. Results show a trend in performance indicators associated to the distinct environmental profiles of the wind farms under observation. The results also highlight the limitations of local and site specific detection and performance analysis approaches and identify the distinct environmental profiles as key phenomenon for consideration in performance evaluation of fault detection methods.
引用
收藏
页码:360 / 365
页数:6
相关论文
共 50 条
  • [1] Wind Turbine Condition Monitoring based on SCADA Data Analysis
    Yin, Haolin
    Jia, Rong
    Ma, Fuqi
    Wang, Dameng
    PROCEEDINGS OF 2018 IEEE 3RD ADVANCED INFORMATION TECHNOLOGY, ELECTRONIC AND AUTOMATION CONTROL CONFERENCE (IAEAC 2018), 2018, : 1101 - 1105
  • [2] Wind Turbine Condition Monitoring Based on SCADA Data Analysis
    Zhang, Jing-Hao
    Hu, Ya-Xin
    Ma, Jiao-Jiao
    Zhen, Dong
    Shi, Zhan-Qun
    2015 INTERNATIONAL CONFERENCE ON MECHANICAL SCIENCE AND MECHANICAL DESIGN, MSMD 2015, 2015, : 162 - 169
  • [3] A Universal Modeling Approach for Wind Turbine Condition Monitoring based on SCADA Data
    Ren, Yan
    Qu, Fuming
    Liu, Jinhai
    Feng, Jian
    Li, Xiaodong
    2017 6TH DATA DRIVEN CONTROL AND LEARNING SYSTEMS (DDCLS), 2017, : 265 - 269
  • [4] condition monitoring method of wind turbine gear box based on SCADA data
    Yin S.
    Hou G.
    Yu X.
    Wang Q.
    Gong L.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2021, 42 (01): : 324 - 332
  • [5] A Condition Monitoring and Fault Isolation System for Wind Turbine Based on SCADA Data
    Liu, Xingchen
    Du, Juan
    Ye, Zhi-Sheng
    IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2022, 18 (02) : 986 - 995
  • [6] Wind Turbine Condition Monitoring Based on SCADA Data-Image Conversion
    Long, Huan
    Xu, Shaohui
    Cai, Huihuang
    Gu, Wei
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73
  • [7] Using SCADA data for wind turbine condition monitoring - a review
    Tautz-Weinert, Jannis
    Watson, Simon J.
    IET RENEWABLE POWER GENERATION, 2017, 11 (04) : 382 - 394
  • [8] Wind turbine condition monitoring by the approach of SCADA data analysis
    Yang, Wenxian
    Court, Richard
    Jiang, Jiesheng
    RENEWABLE ENERGY, 2013, 53 : 365 - 376
  • [9] Comparison of methods for wind turbine condition monitoring with SCADA data
    Wilkinson, Michael
    Darnell, Brian
    van Delft, Thomas
    Harman, Keir
    IET RENEWABLE POWER GENERATION, 2014, 8 (04) : 390 - 397
  • [10] SCADA based nonparametric models for condition monitoring of a wind turbine
    Pandit, Ravi Kumar
    Infield, David
    JOURNAL OF ENGINEERING-JOE, 2019, (18): : 4723 - 4727