Performance evaluation of optimal real-time polymerase chain reaction achieved with reduced voltage

被引:4
作者
Hwang, Ji-Soo [1 ,3 ]
Kim, Jong-Dae [2 ,3 ]
Kim, Yu-Seop [2 ,3 ]
Song, Hye-Jeong [2 ,3 ]
Park, Chan-Young [2 ,3 ]
机构
[1] Hallym Univ, Dept Comp Engn, Chunchon, South Korea
[2] Hallym Univ, Dept Convergence Software, Chunchon, South Korea
[3] Hallym Univ, BioIT Res Ctr, Chunchon, South Korea
来源
BIOMEDICAL ENGINEERING ONLINE | 2018年 / 17卷
基金
新加坡国家研究基金会;
关键词
REACTION CHIP; AMPLIFICATION; DESIGN; SYSTEM; TRENDS; CYCLER;
D O I
10.1186/s12938-018-0579-0
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
BackgroundPolymerase chain reaction (PCR) is used in nucleic acid tests of infectious diseases in point-of-care testing. Previous studies have demonstrated real-time PCR that uses a micro-PCR chip made of packing tape, double-sided tape, and a plastic cover with polycarbonate or polypropylene on a black matte printed circuit board substrate. Despite the success of DNA amplification and fluorescence detection using an early version of the micro-PCR chip, reaching the target temperature was fairly slow and, as a result, the total running time was getting longer. To reduce this runtime, the micro-PCR chip was modified by reducing the heater pattern size of the PCB substrate to one-quarter of the original size or less, while maintaining the ability of the heating pattern to cover the reservoir area of the microfluidic channel. In subsequent experiments, DNA amplification failed several times. During the analysis of the cause of this failure, it was found that the reagent was boiling with the heating range from 25 to 95 degrees C.MethodsAs a method of DNA amplification verification, images were captured by digital single-lens reflex camera to detect FAM fluorescence using diagonal illumination from a blue LED light source. The images were automatically captured at 72 degrees C (the extension step in nucleic acid amplification) and the brightness of the captured images was analyzed to con-firm the success of DNA amplification.ResultsCompared to the previous chip with a larger heating pattern size, the current chip appears to generate excess energy as the size of the heating pattern was reduced. To reduce this excess energy, the initial voltage was lowered to 2V and 2.5V, which is equivalent to a one-fifth and one-quarter voltage-power reduction in pulse width modulation control, respectively. In both voltage reduction cases, the DNA amplification was successful.ConclusionsDNA amplification tests may fail due to the excess energy generated by reducing the heater pattern size of the PCB substrate. However, the tests succeeded when the voltage was reduced to 2V or 2.5V. The 2.5V power test was more efficient for reducing the overall running time.
引用
收藏
页数:11
相关论文
共 22 条
  • [1] Titer-plate formatted continuous flow thermal reactors: Design and performance of a nanoliter reactor
    Chen, Pin-Chuan
    Park, Daniel S.
    You, Byoung-Hee
    Kim, Namwon
    Park, Taehyun
    Soper, Steven A.
    Nikitopoulos, Dimitris E.
    Murphy, Michael C.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2010, 149 (01): : 291 - 300
  • [2] Natural Convection PCR in a Disposable Polymer Chip
    Chung, Kwang Hyo
    Choi, Yo Han
    Jung, Mun Yeon
    [J]. 2009 IEEE SENSORS, VOLS 1-3, 2009, : 1217 - 1220
  • [3] Lab-on-a-Foil: microfluidics on thin and flexible films
    Focke, Maximilian
    Kosse, Dominique
    Mueller, Claas
    Reinecke, Holger
    Zengerle, Roland
    von Stetten, Felix
    [J]. LAB ON A CHIP, 2010, 10 (11) : 1365 - 1386
  • [4] Enhancement of thermal uniformity for a microthermal cycler and its application for polymerase chain reaction
    Hsieh, Tsung-Min
    Luo, Ching-Hsing
    Huang, Fu-Chun
    Wang, Jung-Hao
    Chien, Liang-Ju
    Lee, Gwo-Bin
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2008, 130 (02) : 848 - 856
  • [5] Hwang J., 2015, Int. J. Control Autom, V8, P117, DOI [DOI 10.14257/ijca.2015.8.2.12, 10.14257/ijca.2015.8.2.12, DOI 10.14257/IJCA.2015.8.2.12]
  • [6] Hwang J.-S., 2015, ELECTROPHORESIS, V8, P15, DOI [10.14257/ijca.2015.8.10.02, DOI 10.14257/IJCA.2015.8.10.02]
  • [7] Fluorescence detection test by black printed circuit board based microfluidic channel for polymerase chain reaction
    Hwang, Ji-Soo
    Kim, Yu-Seop
    Song, Hye-Jeong
    Kim, Jong-Dae
    Park, Chan-Young
    [J]. TECHNOLOGY AND HEALTH CARE, 2016, 24 : S139 - S146
  • [8] EFFICIENT CONTROL SYSTEM FOR PCR CHIPS
    Kim, J. D.
    Kim, J.
    Lee, Geumyoung
    [J]. MICROFLUIDICS, BIOMEMS, AND MEDICAL MICROSYSTEMS IX, 2011, 7929
  • [9] Kim JD, 2003, IEICE T FUND ELECTR, VE86A, P859
  • [10] Inhibitory effect of common microfluidic materials on PCR outcome
    Kodzius, Rimantas
    Xiao, Kang
    Wu, Jinbo
    Yi, Xin
    Gong, Xiuqing
    Foulds, Ian G.
    Wen, Weijia
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2012, 161 (01): : 349 - 358