Outcome following isolated tricuspid valve replacement

被引:94
作者
Mangoni, AA
DiSalvo, TG
Vlahakes, GJ
Polanczyk, CA
Fifer, MA [1 ]
机构
[1] Massachusetts Gen Hosp, Dept Med, Div Cardiol, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA USA
[3] Massachusetts Gen Hosp, Dept Surg, Cardiac Surg Div, Boston, MA 02114 USA
关键词
heart valve surgery; tricuspid regurgitation; tricuspid stenosis; tricuspid valve;
D O I
10.1016/S1010-7940(00)00598-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: The clinical outcome of isolated tricuspid valve replacement is not well defined because this procedure is usually performed concomitantly with other valve surgery, Methods: We retrospectively studied the short and long-term outcome of 15 consecutive patients (six men and nine women, aged 61 +/- 3 years) undergoing isolated tricuspid valve replacement from 1984 to 1996. The cause of valve dysfunction was rheumatic heart disease in 12 patients, healed endocarditis in two patients, and sarcoidosis in one patient. The tricuspid valve was stenotic in one patient, regurgitant in eight patients, and both stenotic and regurgitant in six patients. A St. Jude Medical prosthesis was placed in eight patients, Carpentier-Edwards in five patients, and Bjork-Shiley and Starr-Edwards in one patient each. Results: The median survival was only 1.2 years. Three patients (20%) died less than or equal to 30 days after the surgery or before discharge, and six other patients (40%) died within 3 years of surgery. Anasarca was the only predictor of short-term mortality (P = 0.03), while the predictors of long-term mortality were anemia (P = 0.01), rheumatic heart disease (P = 0.03), previous stroke (P = 0.01), and previous mitral valve surgery (P = 0.03). Conclusions: Isolated tricuspid valve replacement is characterized by a poor short and long-term outcome. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:68 / 73
页数:6
相关论文
共 18 条
  • [1] Tricuspid valve surgery and intraoperative echocardiography - Factors affecting survival, clinical outcome, and echocardiographic success
    Bajzer, CT
    Stewart, WJ
    Cosgrove, DM
    Azzam, SJ
    Arheart, KL
    Klein, AL
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (04) : 1023 - 1031
  • [2] BLEIWEIS MS, 1996, J NATL MED ASSOC, V8, P645
  • [3] IN-HOSPITAL AND LONG-TERM OUTCOME AFTER PORCINE TRICUSPID-VALVE REPLACEMENT
    GLOWER, DD
    WHITE, WD
    SMITH, LR
    YOUNG, WG
    OLDHAM, HN
    WOLFE, WG
    LOWE, JE
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1995, 109 (05) : 877 - 884
  • [4] GUERRA F, 1990, J THORAC CARDIOV SUR, V99, P838
  • [5] TRICUSPID-VALVE REPLACEMENT - FACTORS INFLUENCING EARLY AND LATE MORTALITY
    KAUL, TK
    MERCER, JL
    [J]. THORACIC AND CARDIOVASCULAR SURGEON, 1990, 38 (04) : 229 - 235
  • [6] EXCELLENT DURABILITY OF THE HANCOCK PORCINE BIOPROSTHESIS IN THE TRICUSPID POSITION
    KAWACHI, Y
    TOMINAGA, R
    HISAHARA, M
    NAKASHIMA, A
    YASUI, H
    TOKUNAGA, K
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1992, 104 (06) : 1561 - 1566
  • [7] KING RM, 1984, CIRCULATION, V70, P193
  • [8] TRENDS AND RESULTS IN TRICUSPID-VALVE SURGERY
    KRATZ, JM
    CRAWFORD, FA
    STROUD, MR
    APPLEBY, DC
    HANGER, KH
    [J]. CHEST, 1985, 88 (06) : 837 - 840
  • [9] MCGRATH LB, 1990, J THORAC CARDIOV SUR, V99, P124
  • [10] MUNRO AI, 1995, ANN THORAC SURG, V59, pS470