A Monolithic QCM Array Designed for Mounting on a Flow Cell

被引:10
作者
Abe, Takashi [1 ]
Higuchi, Makoto [2 ]
机构
[1] Niigata Univ, Grad Sch Sci & Technol, Nishi Ku, Niigata 9502181, Japan
[2] Nihon Kohden Corp, Tokyo 1610031, Japan
关键词
Array; biosensor; microfluidic channel; monolithic; quartz crystal microbalance (QCM); SYSTEM; RESONATOR;
D O I
10.1109/JSEN.2010.2051662
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A monolithic quartz crystal microbalance (QCM) array fabricated with the excitation electrodes located on the airside and the gold conductive layer on the sensing side was evaluated as a biosensor array in a simple flow cell. The electrode configuration of the new QCM is suitable for sensor applications in flow-cell systems compared with standard QCM because the mounting of the QCM on the flow cell and the electric interconnection between the excitation electrode and oscillation circuit does not require considerable skill and effort. Frequency response to the adsorption of human IgG to anti-human IgG antibody at the concentrations of 0.1-100 mu g/ml was successfully measured, and the results showed that this new sensor can be an alternative to the standard QCM. In addition, the affinity difference between the reference QCM coated with bovine serum albumin for reducing nonspecific binding and the antibody-immobilized QCM to anti-human IgG antibody was simultaneously measured by using the monolithic QCM array within the flow cell. The monolithic QCM array designed for mounting on a flow cell will be expected to use for studying a surface science in a microchannel.
引用
收藏
页码:86 / 90
页数:5
相关论文
共 21 条
  • [1] One-chip multichannel quartz crystal microbalance (QCM) fabricated by Deep RIE
    Abe, T
    Esashi, M
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2000, 82 (1-3) : 139 - 143
  • [2] Design and evaluation of an antiparallel coupled resonator for chemical sensor applications
    Abe, Takashi
    Kato, Hiroshi
    [J]. ANALYTICAL CHEMISTRY, 2007, 79 (17) : 6804 - 6806
  • [3] Real-time measurement of photocatalytic reactions using a monolithic QCM array
    Abe, Takashi
    Kato, Hiroshi
    [J]. JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2009, 19 (09)
  • [4] Dynamical determination of the elastic constants and their temperature coefficients for quartz
    Atanasoff, JV
    Hart, PJ
    [J]. PHYSICAL REVIEW, 1941, 59 (01): : 85 - 96
  • [5] SELECTION OF ADSORBATES FOR CHEMICAL SENSOR ARRAYS BY PATTERN-RECOGNITION
    CAREY, WP
    BEEBE, KR
    KOWALSKI, BR
    ILLMAN, DL
    HIRSCHFELD, T
    [J]. ANALYTICAL CHEMISTRY, 1986, 58 (01) : 149 - 153
  • [6] Bioimprinting of polymers and sol-gel phases. Selective detection of yeasts with imprinted polymers
    Dickert, FL
    Hayden, O
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (06) : 1302 - 1306
  • [7] ODOR-SENSING SYSTEM USING A QUARTZ-RESONATOR SENSOR ARRAY AND NEURAL-NETWORK PATTERN-RECOGNITION
    EMA, K
    YOKOYAMA, M
    NAKAMOTO, T
    MORIIZUMI, T
    [J]. SENSORS AND ACTUATORS, 1989, 18 (3-4): : 291 - 296
  • [8] Pesticide detection using a lateral field excited acoustic wave sensor
    Hu, YH
    Pinkham, W
    French, LA
    Frankel, D
    Vetelino, JF
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2005, 108 (1-2): : 910 - 916
  • [9] A lateral field excited liquid acoustic wave sensor
    Hu, YH
    French, LA
    Radecsky, K
    da Cunha, MP
    Millard, P
    Vetelino, JF
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2004, 51 (11) : 1373 - 1380
  • [10] Multichannel Monolithic Quartz Crystal Microbalance Gas Sensor Array
    Jin, Xiaoxia
    Huang, Yue
    Mason, Andrew
    Zeng, Xiangqun
    [J]. ANALYTICAL CHEMISTRY, 2009, 81 (02) : 595 - 603