Image metric-based correction (Autofocusing) of motion artifacts in high-resolution trabecular bone imaging

被引:32
|
作者
Lin, Wei [1 ]
Ladinsky, Glenn A. [1 ]
Wehrli, Felix W. [1 ]
Song, Hee Kwon [1 ]
机构
[1] Univ Penn, Med Ctr, Lab Struct NMR Imaging, Dept Radiol, Philadelphia, PA 19104 USA
关键词
autofocusing; trablecular bone; motion correction; rotation; navigator;
D O I
10.1002/jmri.20958
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the performance of the autofocusing (AF) motion correction technique in high-resolution trabecular bone imaging where image signal-to noise ratio (SNR) is limited. Materials and Methods: Raw data from 26 clinical three-dimensional (3D) wrist exams were motion corrected using AF for both in-plane rotation and translation. Changes in image metrics (a measurement of image sharpness) and structural parameters subsequently, computed, were used to gauge the performance of the AF algorithm, and comparisons were made with translation-only navigator-corrected results. Results: On average, AF generated images with higher image sharpness compared to the navigator echo technique. The average normalized gradient squared (NGS) metric improved by 0.40%, 0.73%, and 0.84%, respectively, following translation-only navigator, translation-only AF and combined rotation/translation AF. For all structural parameters, the rotation/translation AF resulted in an approximately two-fold greater change compared to the navigator technique. Conclusion: The data provide evidence that errors from subtle translational and rotational motion in the structural parameters in high-resolution trabecular bone images are alleviated by AF and that the resulting improvements are superior to translation-only 2D navigator correction.
引用
收藏
页码:191 / 197
页数:7
相关论文
共 50 条
  • [21] DISPERSIVE EQUATIONS FOR HIGH-RESOLUTION IMAGING AND LATTICE FRINGE ARTIFACTS
    MARKS, LD
    ULTRAMICROSCOPY, 1984, 12 (03) : 237 - 242
  • [22] Application of infrared image detection based on high-resolution image processing in motion recognition
    Yu, Lingling
    OPTICAL AND QUANTUM ELECTRONICS, 2024, 56 (04)
  • [23] Changes in Calcaneal Trabecular Bone Structure Assessed with High-Resolution MR Imaging in Patients with Kidney Transplantation
    T. M. Link
    T. M. Link
    T. M. Link
    O. Saborowski
    K. Kisters
    M. Kempkes
    M. Kosch
    D. Newitt
    Y. Lu
    S. Waldt
    S. Waldt
    S. Majumdar
    Osteoporosis International, 2002, 13 : 119 - 129
  • [24] High-resolution magnetic resonance imaging: Three-dimensional trabecular bone architecture and biomechanical properties
    Majumdar, S
    Kothari, M
    Augat, P
    Newitt, DC
    Link, TM
    Lin, JC
    Lang, T
    Lu, Y
    Genant, HK
    BONE, 1998, 22 (05) : 445 - 454
  • [25] Changes in calcaneal trabecular bone structure assessed with high-resolution MR imaging in patients with kidney transplantation
    Link, TM
    Saborowski, O
    Kisters, K
    Kempkes, M
    Kosch, M
    Newitt, D
    Lu, Y
    Waldt, S
    Majumdar, S
    OSTEOPOROSIS INTERNATIONAL, 2002, 13 (02) : 119 - 129
  • [26] Convergence behavior of high-resolution finite element models of trabecular bone
    Niebur, G.L.
    Yuen, J.C.
    Hsia, A.C.
    Keaveny, T.M.
    Journal of Biomechanical Engineering, 1999, 121 (06): : 629 - 635
  • [27] Convergence behavior of high-resolution finite element models of trabecular bone
    Niebur, GL
    Yuen, JC
    Hsia, AC
    Keaveny, TM
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1999, 121 (06): : 629 - 635
  • [28] Automatic Prospective Registration of High-Resolution Trabecular Bone Images of the Tibia
    Janet Blumenfeld
    Julio Carballido-Gamio
    Roland Krug
    Daniel J. Blezek
    Ileana Hancu
    Sharmila Majumdar
    Annals of Biomedical Engineering, 2007, 35 : 1924 - 1931
  • [29] Automatic prospective registration of high-resolution trabecular bone images of the tibia
    Blumenfeld, Janet
    Carballido-Gamio, Julio
    Krug, Roland
    Blezek, Daniel J.
    Hancu, Ileana
    Majumdar, Sharmila
    ANNALS OF BIOMEDICAL ENGINEERING, 2007, 35 (11) : 1924 - 1931
  • [30] Effects of high-resolution CT of the lung using partial versus full reconstruction on motion artifacts and image noise
    Ha, Hong Il
    Goo, Hyun Woo
    Seo, Joon Beom
    Song, Jae-Woo
    Lee, Jin Seong
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 187 (03) : 618 - 622