Image metric-based correction (Autofocusing) of motion artifacts in high-resolution trabecular bone imaging

被引:32
|
作者
Lin, Wei [1 ]
Ladinsky, Glenn A. [1 ]
Wehrli, Felix W. [1 ]
Song, Hee Kwon [1 ]
机构
[1] Univ Penn, Med Ctr, Lab Struct NMR Imaging, Dept Radiol, Philadelphia, PA 19104 USA
关键词
autofocusing; trablecular bone; motion correction; rotation; navigator;
D O I
10.1002/jmri.20958
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the performance of the autofocusing (AF) motion correction technique in high-resolution trabecular bone imaging where image signal-to noise ratio (SNR) is limited. Materials and Methods: Raw data from 26 clinical three-dimensional (3D) wrist exams were motion corrected using AF for both in-plane rotation and translation. Changes in image metrics (a measurement of image sharpness) and structural parameters subsequently, computed, were used to gauge the performance of the AF algorithm, and comparisons were made with translation-only navigator-corrected results. Results: On average, AF generated images with higher image sharpness compared to the navigator echo technique. The average normalized gradient squared (NGS) metric improved by 0.40%, 0.73%, and 0.84%, respectively, following translation-only navigator, translation-only AF and combined rotation/translation AF. For all structural parameters, the rotation/translation AF resulted in an approximately two-fold greater change compared to the navigator technique. Conclusion: The data provide evidence that errors from subtle translational and rotational motion in the structural parameters in high-resolution trabecular bone images are alleviated by AF and that the resulting improvements are superior to translation-only 2D navigator correction.
引用
收藏
页码:191 / 197
页数:7
相关论文
共 50 条
  • [1] Registration-Based Autofocusing Technique for Automatic Correction of Motion Artifacts in Time-Series Studies of High-Resolution Bone MRI
    Zhang, Ning
    Magland, Jeremy F.
    Song, Hee Kwon
    Wehrli, Felix W.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 41 (04) : 954 - 963
  • [2] Image metric-based correction (autocorrection) of motion effects: Analysis of image metrics
    McGee, KP
    Manduca, A
    Felmlee, JP
    Riederer, SJ
    Ehman, RL
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 2000, 11 (02): : 174 - 181
  • [3] High-resolution magnetic resonance imaging of trabecular bone structure
    Genant, HK
    Majumdar, S
    OSTEOPOROSIS INTERNATIONAL, 1997, 7 (Suppl 3) : 135 - 139
  • [4] High-resolution magnetic resonance imaging of trabecular bone structure
    H. K. Genant
    S. Majumdar
    Osteoporosis International, 1997, 7 : 135 - 139
  • [5] High-resolution AFM imaging of intact and fractured trabecular bone
    Hassenkam, T
    Fantner, GE
    Cutroni, JA
    Weaver, JC
    Morse, DE
    Hansma, PK
    BONE, 2004, 35 (01) : 4 - 10
  • [6] ADAPTIVE MOTION CORRECTION OF HIGH-RESOLUTION MR IMAGING OF THE SHOULDER
    FELMLEE, JP
    EHMAN, RL
    KORIN, HW
    RADIOLOGY, 1992, 185 : 303 - 303
  • [7] Laser autofocusing system for high-resolution cell biological imaging
    Liron, Y
    Paran, Y
    Zatorsky, NG
    Geiger, B
    Kam, Z
    JOURNAL OF MICROSCOPY, 2006, 221 : 145 - 151
  • [8] Image-based assessment of spinal trabecular bone structure from high-resolution CT images
    Gordon, CL
    Lang, TF
    Augat, P
    Genant, HK
    OSTEOPOROSIS INTERNATIONAL, 1998, 8 (04) : 317 - 325
  • [9] Image-Based Assessment of Spinal Trabecular Bone Structure from High-Resolution CT Images
    C. L. Gordon
    T. F. Lang
    P. Augat
    H. K. Genant
    Osteoporosis International, 1998, 8 : 317 - 325
  • [10] On the Significance of Motion Degradation in High-resolution 3D μMRI of Trabecular Bone
    Bhagat, Yusuf A.
    Rajapakse, Chamith S.
    Magland, Jeremy F.
    Wald, Michael J.
    Song, Hee Kwon
    Leonard, Mary B.
    Wehrli, Felix W.
    ACADEMIC RADIOLOGY, 2011, 18 (10) : 1205 - 1216