Developing a Device for Monitoring O2 Saturation in Blood

被引:1
|
作者
Sanchez-Perez, Karla J. [1 ]
Herrera-Vega, Javier [1 ]
Sucar-Succar, Enrique [1 ]
Orilluela-Espina, Felipe [1 ]
Trevino-Palacios, Carlos G. [1 ]
机构
[1] Inst Nacl Astrofis Opt & Electr, Puebla 72840, Mexico
来源
关键词
NIRS; Oximeter; CW-pulsed operation;
D O I
10.1063/1.4901393
中图分类号
O59 [应用物理学];
学科分类号
摘要
We present a single-channel device for monitoring oxygen saturation in blood using near infrared light (NIR). This device measures the differential absorption of both oxi-hemoglobin (HbO(2)) and deoxi-hemoglobin (HHb) concentrations using wavelengths within the biophotonic window (700 nm -1100 nm). Our device works with two wavelengths: the first source (lambda(1) = 632 nm) operates in continuous wave (CW) and the second (lambda(2) = 940 nm) operates in pulsed mode. The pulsed signal at lambda(2) operates in a 20% fill factor. The CW signal provides information related to the arterial pulse, whereas both CW and pulsed signal provide information about blood oxygenation. Light emitted from the sources travels through the tissue and are collected on the detector by transmission. Measurements of blood oxygenation measured in transmission on fingers tips are presented which are comparable to commercial devices. The values obtained are above 90.0% blood oxygenation in healthy tests subjects with 0.1% accuracy in the measurements.
引用
收藏
页码:201 / 204
页数:4
相关论文
共 50 条
  • [1] CONTINUOUS MONITORING OF O2 SATURATION - REPLY
    KUFF, JV
    PURI, VK
    CHEST, 1989, 96 (04) : 956 - 957
  • [2] Routine Monitoring of O2 Saturation: Early Experience
    Reyes, Meredith
    Chen, Alice
    Allison, Paul
    Korte, Laura
    Radovancevic, Rajko
    Guerrettaz, Patricia
    Bracey, Arthur
    TRANSFUSION, 2013, 53 (08) : 6A - 7A
  • [3] BLOOD O2 SATURATION DETERMINATION IN FROZEN TISSUE
    SINHA, AK
    NEUBAUER, JA
    LIPP, JA
    WEISS, HR
    MICROVASCULAR RESEARCH, 1977, 14 (02) : 133 - 144
  • [4] HIGH CO2 AND BLOOD O2 SATURATION
    MACARTHUR, JD
    BROWN, EB
    FEDERATION PROCEEDINGS, 1958, 17 (01) : 101 - 101
  • [5] INFLUENCE OF O2 SATURATION OF BLOOD ON PLASMA PH VALUE
    SCHULTEH.D
    VONMENGD.HJ
    THEWS, G
    PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1968, 300 (01): : R6 - &
  • [6] CONTINUOUS MONITORING OF O2 SATURATION IN INTENSIVE-CARE UNIT
    KRAUSS, XH
    VERDOUW, PD
    HUGENHOL.PG
    POLANYI, ML
    HAGEMEIJ.F
    CIRCULATION, 1972, 46 (04) : 178 - &
  • [7] RELIABILITY OF CAPILLARY BLOOD FOR MEASUREMENT OF PO2 AND O2 SATURATION
    STAMM, SJ
    DISEASES OF THE CHEST, 1967, 52 (02): : 191 - &
  • [8] COMPARISON OF ARTERIAL O2 SATURATION WITH TISSUE O2 LEVELS
    BEHRMANN, VG
    GRIEST, WD
    MANGUN, GH
    HARTMAN, FW
    FEDERATION PROCEEDINGS, 1950, 9 (01) : 10 - 10
  • [9] Interest of monitoring of O2 tissue saturation (StO2) in cardiac surgery
    Jabbour, K.
    Khalil, E.
    Haddad, F.
    Hayek, G.
    Madi-Jebara, S.
    ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 2014, 33 : A329 - A329
  • [10] O2 saturation and slings -: Reply
    Stening, W
    Nitsch, P
    Roth, B
    PEDIATRICS, 2004, 113 (01) : 169 - 170