A side-by-side LYSO/GAGG phoswich detector aiming for SPECT imaging

被引:15
|
作者
Wei, Qingyang [1 ]
Ma, Tianyu [2 ]
Jiang, Nianming [3 ]
Xu, Tianpeng [3 ]
Lyu, Zhenlei [2 ]
Hu, Yulin [1 ]
Liu, Yaqiang [2 ]
机构
[1] Univ Sci & Technol Beijing, Beijing Engn Res Ctr Ind Spectrum Imaging, Sch Automat & Elect Engn, Beijing 100083, Peoples R China
[2] Tsinghua Univ, Dept Engn Phys, Beijing 100084, Peoples R China
[3] Beijing Novel Med Equipment Ltd, Beijing 102206, Peoples R China
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 2020年 / 953卷 / 953期
基金
中国国家自然科学基金;
关键词
SPECT; Phoswich detector; LYSO/GAGG; SiPM; High performances; SMALL-ANIMAL SPECT; PERFORMANCE EVALUATION; PET; LYSO; ACCURACY; COMPACT; DESIGN; SYSTEM;
D O I
10.1016/j.nima.2019.163242
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Single photon emission computed tomography (SPECT) is an effective metabolic and functional imaging technique in both clinical and pre-clinical applications. Gamma-ray detector is a key component of a SPECT system. High performance detectors are required for high-quality SPECT imaging. In this paper, a detector using a side-by-side LYSO/GAGG phoswich array read out by a sparse 8 x 8 SiPM array is developed. The phoswich crystals are discriminated using pulse waveform integration to peak ratio. A Tc-99m and a Co-57 source irradiation experiments were conducted. Results of the experiments demonstrate that the LYSO and GAGG can be clearly discriminated using the simple parameter. 12 x 12 of both LYSO and GAGG crystal arrays with a crystal size of 1.35 x 2.7 x 7 mm(3) could be successfully distinguished. The average energy resolutions @140 keV of 12 x 12 LYSO crystals and 12 x 12 GAGG crystals are 26.23% and 21.29%, respectively. The calculation and experiment verifies that the side-by-side LYSO/GAGG phoswich detector achieves relatively high resolution and high sensitivity which is suitable for high performance SPECT systems.
引用
收藏
页数:6
相关论文
共 8 条
  • [1] A position sensitive scintillation detector using a side-by-side GAGG-F/GAGG-T phoswich block
    Wei, Q.
    Jiang, N.
    Xu, T.
    Lyu, Z.
    Ma, T.
    Liu, Y.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (04):
  • [2] Performance evaluation of side-by-side optically coupled monolithic LYSO crystals
    Freire, Marta
    Echegoyen, Sara
    Gonzalez-Montoro, Andrea
    Sanchez, Filomeno
    Gonzalez, Antonio J.
    MEDICAL PHYSICS, 2022, 49 (08) : 5616 - 5626
  • [3] Simulation Study of Side-By-Side Phoswich PET Detector Configuration for Providing High Spatial Resolution of <0.4 mm
    Han, Soo Kyeong
    Yang, Jingyu
    Hong, Sungsoo
    Kang, Jihoon
    2018 JOINT 10TH INTERNATIONAL CONFERENCE ON SOFT COMPUTING AND INTELLIGENT SYSTEMS (SCIS) AND 19TH INTERNATIONAL SYMPOSIUM ON ADVANCED INTELLIGENT SYSTEMS (ISIS), 2018, : 346 - 349
  • [4] Endocrine neoplasm scintigraphy - Added value of fusing SPECT/CT images compared with traditional side-by-side analysis
    Ingui, Christian J.
    Shah, Nirav P.
    Oates, M. Elizabeth
    CLINICAL NUCLEAR MEDICINE, 2006, 31 (11) : 665 - 672
  • [5] Operational control based on environmental detector for floating LNG connection system during side-by-side offloading operation
    Liang, Xiaoling
    Zhang, Yuxiang
    Ge, Shuzhi Sam
    How, Bernard Voon Ee
    NONLINEAR DYNAMICS, 2021, 106 (03) : 2293 - 2307
  • [6] Physiological Assessment of Myocardial Perfusion Using Nuclear Cardiology Would Enhance Coronary Artery Disease Patient Care -Which Imaging Modality Is Best for Evaluation of Myocardial Ischemia? (SPECT-Side)-
    Yoshinaga, Keiichiro
    Manabe, Osamu
    Tamaki, Nagara
    CIRCULATION JOURNAL, 2011, 75 (03) : 713 - 722
  • [7] Imaging the pre- and postsynaptic side of striatal dopaminergic synapses in idiopathic cervical dystonia:: A SPECT study using [123I] epidepride and [123I] β-CIT
    Naumann, M
    Pirker, W
    Reiners, K
    Lange, KW
    Becker, G
    Brücke, T
    MOVEMENT DISORDERS, 1998, 13 (02) : 319 - 323
  • [8] Toward Optimized 89Zr-Immuno-PET: Side-by-Side Comparison of [89Zr]Zr-DFO-, [89Zr]Zr-3,4,3-(LI-1,2-HOPO)- and [89Zr]Zr-DFO*-Cetuximab for Tumor Imaging: Which Chelator Is the Most Suitable?
    Damerow, Helen
    Cheng, Xia
    von Kiedrowski, Valeska
    Schirrmacher, Ralf
    Waengler, Bjoern
    Fricker, Gert
    Waengler, Carmen
    PHARMACEUTICS, 2022, 14 (10)