Monolithic LaBr3:Ce crystals on silicon photomultiplier arrays for time-of-flight positron emission tomography

被引:47
作者
Seifert, Stefan [1 ]
van Dam, Herman T. [1 ]
Huizenga, Jan [1 ]
Vinke, Ruud [2 ]
Dendooven, Peter [2 ]
Lohner, Herbert [2 ]
Schaart, Dennis R. [1 ]
机构
[1] Delft Univ Technol, NL-2629 JB Delft, Netherlands
[2] Univ Groningen, KVI, NL-9747 AA Groningen, Netherlands
关键词
SCINTILLATOR PET DETECTORS; ENERGY RESOLUTION; PERFORMANCE; DEPTH; MODEL;
D O I
10.1088/0031-9155/57/8/2219
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Positron emission tomography detectors based on monolithic scintillation crystals exhibit good spatial and energy resolution, intrinsically provide depth-of-interaction information, have high gamma-photon capture efficiency, and may reduce the manufacturing costs compared to pixelated crystal arrays. Here, we present the characterization of a detector consisting of a 18.0 mm x 16.2 mm x 10.0 mm monolithic LaBr3:5%Ce scintillator directly coupled to a 4 x 4 array of silicon photomultipliers. An energy resolution of 6.4% full-width-at-half-maximum (FWHM) was obtained. The point-spread-function (PSF) was determined for different regions of the detector. The full-width-at-half-maximum (FWHM) of the PSF was measured to be <1.5 mm at the center of the detector and <1.7 mm averaged over the entire crystal. Both values are not corrected for the similar to 0.6 mm FWHM test beam diameter. Furthermore, the influence of edge effects was investigated. We found that near the edges of the detector the spatial resolution degrades to 2.2 mm (FWHM), and a bias in the position estimates, up to 1.5 mm, was observed. Moreover, the coincidence resolving time for two identical detectors in coincidence was measured to be as small as similar to 198 ps FWHM.
引用
收藏
页码:2219 / 2233
页数:15
相关论文
共 28 条
[11]   Multi-Pixel Photon Counters for TOF PET Detector and Its Challenges [J].
Kim, Chang Lyong ;
Wang, Gin-Chung ;
Dolinsky, Sergei .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (05) :2580-2585
[12]   An Assessment of the Impact of Incorporating Time-of-Flight Information into Clinical PET/CT Imaging [J].
Lois, Cristina ;
Jakoby, Bjoern W. ;
Long, Misty J. ;
Hubner, Karl F. ;
Barker, David W. ;
Casey, Michael E. ;
Conti, Maurizio ;
Panin, Vladimir Y. ;
Kadrmas, Dan J. ;
Townsend, David W. .
JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (02) :237-245
[13]   Experimental characterization of monolithic-crystal small animal PET detectors read out by APD arrays [J].
Maas, Marnix C. ;
van der Laan, D. J. ;
Schaart, Dennis R. ;
Huizenga, Jan ;
Brouwer, J. C. ;
Bruyndonckx, Peter ;
Leonard, Sophie ;
Lemaitre, Cedric ;
van Eijk, Carel W. E. .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (03) :1071-1077
[14]   Model of the point spread function of monolithic scintillator PET detectors for perpendicular incidence [J].
Maas, Marnix C. ;
van der Laan, D. J. ;
van Eijk, Carel W. E. ;
Schaart, Dennis R. ;
Beekman, Freek J. ;
Bruyndonckx, Peter ;
Lemaitre, Cedric .
MEDICAL PHYSICS, 2010, 37 (04) :1904-1913
[15]   Monolithic scintillator PET detectors with intrinsic depth-of-interaction correction [J].
Maas, Marnix C. ;
Schaart, Dennis R. ;
van der Laan, D. J. ;
Bruyndonckx, Peter ;
Lemaitre, Cedric ;
Beekman, Freek J. ;
van Eijk, Carel W. E. .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (07) :1893-1908
[16]   Recent advances and future advances in time-of-flight PET [J].
Moses, William W. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (02) :919-924
[17]   Energy resolution of scintillation detectors readout with large area avalanche photodiodes and photomultipliers [J].
Moszynski, M ;
Kapusta, M ;
Wolski, D ;
Szawlowski, M ;
Klamra, W .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) :472-477
[18]   The road to the common PET/CT detector [J].
Nassalski, Antoni ;
Moszynski, Marek ;
Szczesniak, Tomasz ;
Wolski, Dariusz ;
Batsch, Tadeusz .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (05) :1459-1463
[19]   LaBr3:Ce and SiPMs for time-of-flight PET: achieving 100 ps coincidence resolving time [J].
Schaart, Dennis R. ;
Seifert, Stefan ;
Vinke, Ruud ;
van Dam, Herman T. ;
Dendooven, Peter ;
Lohner, Herbert ;
Beekman, Freek J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (07) :N179-N189
[20]   A novel, SiPM-array-based, monolithic scintillator detector for PET [J].
Schaart, Dennis R. ;
van Dam, Herman T. ;
Seifert, Stefan ;
Vinke, Ruud ;
Dendooven, Peter ;
Lohner, Herbert ;
Beekman, Freek J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (11) :3501-3512