A practical parity scheme for tolerating triple disk failures in RAID architectures

被引:0
作者
Park, CW
Han, YY
机构
[1] Elect & Telecommun Res Inst, Taejon 305350, South Korea
[2] Hanyang Univ, Div Elect & Comp Engn, Seoul 133791, South Korea
来源
ADVANCES IN COMPUTING SCIENCE-ASIAN 2000, PROCEEDINGS | 2000年 / 1961卷
关键词
D O I
暂无
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
Although theoretical methods were proposed for tolerating multiple disk failures, their complexities are too high to be practically applicable. In this paper, we proposed a practical parity scheme for tolerating simultaneous triple disk failures in RAID architectures. We first formalized the problems with matrix operations. Our scheme is practical in the sense that it employs three redundant disks for tolerating triple disk failures. Furthermore, it requires simple arithmetic computations only, and it can easily be implemented on current RAID controllers.
引用
收藏
页码:58 / 68
页数:11
相关论文
共 50 条
[21]   A hybrid scheme for tolerating mobile support station failures [J].
Abd-El-Barr, MIH ;
Khan, SA .
PARALLEL AND DISTRIBUTED COMPUTING SYSTEMS, 2001, :436-441
[22]   A study on architectures of RAID level 4 disk arrays [J].
Fukumoto, S ;
Hayashi, I ;
Ishii, N ;
Nakagawa, T .
STOCHASTIC MODELLING IN INNOVATIVE MANUFACTURING, 1997, 445 :281-291
[23]   A toleration based extended RAID code triple failures [J].
Wan, Wu-Nan ;
Yang, Wei ;
Chen, Yun .
Beijing Youdian Daxue Xuebao/Journal of Beijing University of Posts and Telecommunications, 2014, 37 (05) :75-79
[24]   MP-RAID: Mirroring and parity protected disk array [J].
毛波 ;
冯丹 ;
吴素贞 .
Journal of Shanghai University(English Edition), 2009, 13 (06) :444-449
[25]   HARDWARE REDUNDANCY RECONFIGURATION SCHEME FOR TOLERATING MULTIPLE MODULE FAILURES [J].
SU, SYH ;
DUCASSE, E .
IEEE TRANSACTIONS ON COMPUTERS, 1980, 29 (03) :254-258
[26]   MP-RAID: Mirroring and parity protected disk array [J].
毛波 ;
冯丹 ;
吴素贞 .
Advances in Manufacturing, 2009, (06) :444-449
[27]   A dynamic parity grouping for efficient parity buffering for RAID-5 disk arrays [J].
Yu, PS ;
Wu, KL ;
Dan, A .
COMPUTER SYSTEMS SCIENCE AND ENGINEERING, 2000, 15 (03) :155-163
[28]   A multiple disk failure recovery scheme in RAID systems [J].
Park, CW ;
Park, JW .
JOURNAL OF SYSTEMS ARCHITECTURE, 2004, 50 (04) :169-175
[29]   Modified low-density MDS array codes for tolerating double disk failures in disk arrays [J].
Fujita, Hachiro ;
Sakaniwa, Kohichi .
IEEE TRANSACTIONS ON COMPUTERS, 2007, 56 (04) :563-566
[30]   Modified low-density MDS array codes for tolerating double disk failures in disk arrays [J].
Superrobust Computation Project, The University of Tokyo, 5-1-5 Kashihanoha, Kashiwa, Chiba 277-8561, Japan ;
不详 .
IEEE Trans Comput, 2007, 4 (563-566) :563-566