Novel impedimetric immunosensor for the detection and quantitation of Adenovirus using reduced antibody fragments immobilized onto a conducting copolymer surface

被引:24
作者
Caygill, Rebecca L. [1 ]
Hodges, Christopher S. [2 ]
Holmes, Joanne L. [3 ]
Higson, Seamus P. J. [3 ]
Blair, G. Eric [4 ]
Millner, Paul A. [1 ]
机构
[1] Univ Leeds, Biosensors & Biocatalysis Lab, Inst Membrane & Syst Biol, Fac Biol Sci, Leeds LS2 9JT, W Yorkshire, England
[2] Univ Leeds, Sch Proc Environm & Mat Engn, Leeds LD2 9JT, W Yorkshire, England
[3] Cranfield Univ, Cranfield MK43 0AL, Beds, England
[4] Univ Leeds, Inst Mol & Cellular Biol, Fac Biol Sci, Leeds LS2 9JT, W Yorkshire, England
基金
英国生物技术与生命科学研究理事会;
关键词
Electrochemical impedance spectroscopy (EIS); Adenovirus; Immunosensor; Detection; Biosensor; VIRUS; DNA; HYBRIDIZATION; AGENT;
D O I
10.1016/j.bios.2011.11.041
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The number of Adenovirus (Ad) infections detected in immunocompromised people has increased due to the number of patients receiving transplants, as well as the HIV pandemic. Ads cause life-threatening diseases specific to the infected organs of immunocompromised hosts, with discontinuation of immunosuppressive agents necessary to prevent morbidity. The methodology in this paper has been employed to develop a novel impedimetric based assay platform to detect and quantify human Ads, which is comparable in performance to current methods, such as ELISA and PCR, but is also less expensive and faster. Novel immunosensors have been fabricated using polyclonal antibodies raised against a human Ad (Ad5) capsid protein, which were selectively cleaved into antibody fragments by 2-mercaptoethylamine. The fragments were immobilized onto a functionalized conducting copolymer matrix comprising polyaniline and 2-aminobenzylamine. Fully fabricated sensors were incubated with two immunologically distinct serotypes of Ad, Ad5 and Ad3, with between 10 and 10(12) virus particles/mL prior to sensor interrogation. Electrochemical impedance spectroscopy was used to measure the charge transfer resistance of the sensors over a range of frequencies from 25 kHz to 0.1 Hz. Our data demonstrate that the immunosensors specifically detect, and differentiate between, closely related human Ad serotypes with a limit of detection of 10(3) virus particles/mL. In addition, atomic force microscopy was applied to study the sensor surface nanostructure. Future work looks to test virus containing clinical samples but this could be a viable and valuable alternative for point-of-care virus detection and quantification. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:104 / 110
页数:7
相关论文
共 33 条
  • [1] SIMPLE PROCEDURE FOR DISCRIMINATION AND TYPING OF ENTERIC ADENOVIRUSES AFTER DETECTION BY POLYMERASE CHAIN-REACTION
    ALLARD, A
    KAJON, A
    WADELL, G
    [J]. JOURNAL OF MEDICAL VIROLOGY, 1994, 44 (03) : 250 - 257
  • [2] PHARYNGOCONJUNCTIVAL FEVER - EPIDEMIOLOGICAL STUDIES OF A RECENTLY RECOGNIZED DISEASE ENTITY
    BELL, JA
    ROWE, WP
    ENGLER, JI
    PARROTT, RH
    HUEBNER, RJ
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1955, 157 (13): : 1083 - 1092
  • [3] Directed immobilization of reduced antibody fragments onto a novel SAM on gold for myoglobin impedance immunosensing
    Billah, Md Morsaline
    Hodges, Christopher S.
    Hays, Henry C. W.
    Millner, P. A.
    [J]. BIOELECTROCHEMISTRY, 2010, 80 (01) : 49 - 54
  • [4] Development of a myoglobin impedimetric immunosensor based on mixed self-assembled monolayer onto gold
    Billah, Morsaline
    Hays, Henry C. W.
    Millner, Paul A.
    [J]. MICROCHIMICA ACTA, 2008, 160 (04) : 447 - 454
  • [5] ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
    CLARK, LC
    LYONS, C
    [J]. ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1962, 102 (01) : 29 - &
  • [6] Hybridization biosensor using 2,9-dimethyl-1,10-phenantroline cobalt as electrochemical indicator for detection of hepatitis B virus DNA
    Ding, Caifeng
    Zhao, Fei
    Zhang, Meiling
    Zhang, Shusheng
    [J]. BIOELECTROCHEMISTRY, 2008, 72 (01) : 28 - 33
  • [7] FADEN H, 1985, AM J PEDIAT HEMATOL, V7, P15
  • [8] A label-free immunosensor for diagnosis of dengue infection with simple electrical measurements
    Fang, Xiaoqin
    Tan, Ooi Kiang
    Tse, Man Siu
    Ooi, Eng Eong
    [J]. BIOSENSORS & BIOELECTRONICS, 2010, 25 (05) : 1137 - 1142
  • [9] Defining the role of CD46, CD80 and CD86 in mediating adenovirus type 3 fiber interactions with host cells
    Hall, Kathryn
    Zajdel, Maria E. Blair
    Blair, G. Eric
    [J]. VIROLOGY, 2009, 392 (02) : 222 - 229
  • [10] HARLOW E, 1988, ANTIBODIES LAB MANUA, P617