Assessing fluid change in hemodialysis: Whole body versus sum of segmental bioimpedance spectroscopy

被引:37
|
作者
Chanchairujira, T [1 ]
Mehta, RL [1 ]
机构
[1] Univ Calif San Diego, Med Ctr, Dept Med, Div Nephrol, San Diego, CA USA
关键词
bioimpedance spectroscopy; hemodialysis; chronic hemodialysis; body water; electrical conduction; dialysis related morbidity; hypotension;
D O I
10.1046/j.1523-1755.2001.00074.x
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background. Accurate estimation of extracellular fluid (ECF) is an important factor in assessing dry weight in hemodialysis patients. Bioimpedance spectroscopy (BIS) is a simple method to determine the compartmental distribution of body water in HD patients. Recent studies have shown that sum of segmental BIS (SBIS) is less affected by the change of body position and may be more accurate in measuring ECF change than whole body BIS (WBIS). We have compared SBIS and WBIS in estimating change in fluid volume during hemodialysis. Methods. Twenty-eight patients (male 10, female 18) were studied during their regular hemodialysis. ECF changes estimated by both techniques were compared with actual weight change during the inter- and intradialytic periods. Results. Both techniques tracked fluid changes that correlated well with fluid loss during the dialysis run (WBIS, r = 0.75, P < 0.001; SBIS, r = 0.65, P < 0.001) and fluid gain in the interdialytic period (WBIS, r = 0.73, P < 0.01; SBIS, r = 0.6, P < 0.01). ECF changes estimated by SBIS and WBIS underestimated weight loss 0.78 +/- 0.01 L and 0.6 +/- 0.01 L, respectively; and underestimated weight gain 0.66 +/- 0.18 L and 0.76 +/- 0.18 L, respectively. Conclusions. While both WBIS and SBIS can be used to track relative ECF volume changes in HD patients, they are not accurate in quantifying changes in ECF volume. More studies are needed to evaluate the benefit of SBIS over WBIS in clinical practice.
引用
收藏
页码:2337 / 2342
页数:6
相关论文
共 31 条
  • [1] Importance of Whole-Body Bioimpedance Spectroscopy for the Management of Fluid Balance
    Wabel, Peter
    Chamney, Paul
    Moissl, Ulrich
    Jirka, Tomas
    BLOOD PURIFICATION, 2009, 27 (01) : 75 - 80
  • [2] A model of artefacts produced by stray capacitance during whole body or segmental bioimpedance spectroscopy
    Scharfetter, H
    Hartinger, P
    Hinghofer-Szalkay, H
    Hutten, H
    PHYSIOLOGICAL MEASUREMENT, 1998, 19 (02) : 247 - 261
  • [3] Fluid balance assessment in pediatric hemodialysis patients by using whole-body bioimpedance spectroscopy (WB-BIS)
    Ei E. Khin
    Ayah Y. Elmaghrabi
    Luis A. Alvarado
    Vinai Modem
    Raymond Quigley
    Pediatric Nephrology, 2022, 37 : 2449 - 2456
  • [4] Effect of change in fluid distribution in segments in hemodialysis patients at different ultrafiltration rates on accuracy of whole body bioimpedance measurement
    Abbas, Samer R.
    Zhu, Fansan
    Kaysen, George A.
    Kotanko, Peter
    Levin, Nathan W.
    JOURNAL OF APPLIED PHYSIOLOGY, 2014, 116 (11) : 1382 - 1389
  • [5] Fluid balance assessment in pediatric hemodialysis patients by using whole-body bioimpedance spectroscopy ( WB-BIS)
    Khin, Ei E.
    Elmaghrabi, Ayah Y.
    Alvarado, Luis A.
    Modem, Vinai
    Quigley, Raymond
    PEDIATRIC NEPHROLOGY, 2022, 37 (10) : 2449 - 2456
  • [6] Novel equations for bioimpedance spectroscopy to calculate body fluid volume based on the agreement between body weight and extracellular water change before and after hemodialysis as a guide
    Yashiro, Masatomo
    Kotera, Hirohisa
    RENAL REPLACEMENT THERAPY, 2019, 5 (01)
  • [7] Novel equations for bioimpedance spectroscopy to calculate body fluid volume based on the agreement between body weight and extracellular water change before and after hemodialysis as a guide
    Masatomo Yashiro
    Hirohisa Kotera
    Renal Replacement Therapy, 5
  • [8] Effect of body mass index (BMI) on estimation of extracellular volume (ECV) in hemodialysis (FID) patients using segmental and whole body bioimpedance analysis
    Carter, M
    Morris, AT
    Zhu, FS
    Zaluska, W
    Levin, NW
    PHYSIOLOGICAL MEASUREMENT, 2005, 26 (02) : S93 - S99
  • [9] Comparison of whole body versus thoracic bioimpedance in relation to ultrafiltration volume and systolic blood pressure during hemodialysis
    Schoutteten, Melanie K.
    Lindeboom, Lucas
    Brys, Astrid
    Lanssens, Dorien
    Smeets, Christophe J. P.
    De Canniere, Helene
    De Moor, Bart
    Peeters, Jacques
    Heylen, Line
    Van Hoof, Chris
    Groenendaal, Willemijn
    Kooman, Jeroen P.
    Vandervoort, Pieter M.
    JOURNAL OF APPLIED PHYSIOLOGY, 2023, 135 (06) : 1330 - 1338
  • [10] Role of bioimpedance spectroscopy in assessment of body water compartments in hemodialysis patients
    Cox-Reijven, PL
    Kooman, JP
    Soeters, PB
    van der Sande, FM
    Leunissen, KML
    AMERICAN JOURNAL OF KIDNEY DISEASES, 2001, 38 (04) : 832 - 838