Negative-pressure ventilation improves cardiac output after right heart surgery

被引:0
|
作者
Shekerdemian, LS
Shore, DF
Lincoln, C
Bush, A
Redington, AN
机构
[1] UNIV LONDON IMPERIAL COLL SCI TECHNOL & MED,NATL HEART & LUNG INST,ROYAL BROMPTON HOSP,LONDON SW3 6NP,ENGLAND
[2] UNIV LONDON IMPERIAL COLL SCI TECHNOL & MED,NATL HEART & LUNG INST,ROYAL BROMPTON HOSP,LONDON SW3 6NP,ENGLAND
关键词
cardiac output; ventilation; tetralogy of Fallot; Fontan procedure;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background A low cardiac output state can complicate the postoperative course of patients undergoing Fontan-type operations and tetralogy of Fallot repair. Methods and Results We investigated the effect of negative pressure ventilation on cardiac output in 11 children in the early postoperative period after right heart surgery. All patients were initially ventilated with volume-cycled intermittent positive-pressure ventilation, and negative-pressure ventilation was delivered with the Hayek external high-frequency oscillator. Cardiac output was calculated by the direct Fick method, oxygen consumption being measured by respiratory mass spectrometry. Cardiac output was measured during intermittent positive-pressure ventilation and after 15 minutes of negative-pressure ventilation. Negative-pressure ventilation improved the cardiac output by a mean of 46% (P=.005). Heart rate did not change, and stroke volume increased by a mean of 48.5% (P=.005). Mixed venous saturation increased by 4.6% (P<.02), and consequently arteriovenous oxygen content difference fell significantly (P=.01). The systemic and pulmonary vascular resistances were reduced significantly during negative-pressure ventilation (P<.05 and P<.03, respectively). Conclusions Negative-pressure ventilation improves cardiac output in children after total cavopulmonary connection and tetralogy of Fallot repair and may prove to be an important therapeutic option in children with the low cardiac output state.
引用
收藏
页码:49 / 55
页数:7
相关论文
共 50 条
  • [11] Electrical velocimetry as a tool for measuring cardiac output in small infants after heart surgery
    Oswin Grollmuss
    Serge Demontoux
    André Capderou
    Alain Serraf
    Emre Belli
    Intensive Care Medicine, 2012, 38 : 1032 - 1039
  • [12] Noninvasive cardiac output assessment during heart surgery
    Ceriana P.
    Maurelli M.
    Braschi A.
    Baiardi P.
    Amici D.D.
    Journal of Clinical Monitoring and Computing, 2002, 17 (02) : 147 - 149
  • [13] Cardiac output monitoring by pressure recording analytical method in cardiac surgery
    Giomarelli, P
    Biagioli, B
    Scolletta, S
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2004, 26 (03) : 515 - 520
  • [14] IMPROVEMENT IN CARDIAC-OUTPUT DURING AIRWAY PRESSURE RELEASE VENTILATION
    FALKENHAIN, SK
    REILLEY, TE
    GREGORY, JS
    CRITICAL CARE MEDICINE, 1992, 20 (09) : 1358 - 1360
  • [15] Arm occlusion pressure is a useful predictor of an increase in cardiac output after fluid loading following cardiac surgery
    Geerts, Bart F.
    Maas, Jacinta
    de Wilde, Rob B. P.
    Aarts, Leon P. H. J.
    Jansen, Jos R. C.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2011, 28 (11) : 802 - 806
  • [16] Prognostic value of low cardiac output early after cardiac surgery
    M Berthet
    Critical Care, 8 (Suppl 1):
  • [17] Corrected right ventricular end-diastolic volume and initial distribution volume of glucose correlate with cardiac output after cardiac surgery
    Junichi Saito
    Hironori Ishihara
    Eiji Hashiba
    Hirobumi Okawa
    Tomoyuki Kudo
    Masahiro Sawada
    Toshihito Tsubo
    Kazuyoshi Hirota
    Journal of Anesthesia, 2013, 27 : 512 - 520
  • [18] Corrected right ventricular end-diastolic volume and initial distribution volume of glucose correlate with cardiac output after cardiac surgery
    Saito, Junichi
    Ishihara, Hironori
    Hashiba, Eiji
    Okawa, Hirobumi
    Kudo, Tomoyuki
    Sawada, Masahiro
    Tsubo, Toshihito
    Hirota, Kazuyoshi
    JOURNAL OF ANESTHESIA, 2013, 27 (04) : 512 - 520
  • [19] Cardiac output measured by a new arterial pressure waveform analysis method without calibration compared with thermodilution after cardiac surgery
    Breukers, Rose-Marieke B. G. E.
    Sepehrkhouy, Shahrzad
    Spiegelenberg, Stefan R.
    Groeneveld, A. B. Johan
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2007, 21 (05) : 632 - 635
  • [20] Negative pressure breathing increases cardiac output and nitrogen elimination in seated subjects
    Lundgren, Claes E. G.
    Eckhardt, Lukas G.
    Senf, Curtis J.
    Bowdwin, Melina R.
    Pendergast, David R.
    UNDERSEA AND HYPERBARIC MEDICINE, 2013, 40 (05) : 403 - 410