In Vivo Stability of Hydroxyapatite Nanoparticles Coated on Titanium Implant Surfaces

被引:0
|
作者
Wennerberg, Ann [1 ,2 ]
Jimbo, Ryo [1 ,2 ]
Allard, Stefan [3 ]
Skarnemark, Gunnar [3 ]
Andersson, Martin [3 ]
机构
[1] Malmo Univ, Fac Odontol, Dept Prosthodont, Malmo, Sweden
[2] Univ Gothenburg, Sahlgrenska Acad, Dept Biomat, Gothenburg, Sweden
[3] Chalmers, Dept Chem & Biol Engn, S-41296 Gothenburg, Sweden
基金
瑞典研究理事会;
关键词
implant; in vivo; nanocoat instability; CALCIUM-PHOSPHATE; OSTEOBLAST ADHESION; ENDOSSEOUS IMPLANTS; BONE-FORMATION; NANO; OSSEOINTEGRATION; CELLS; DOGS; RAT;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: Nanotechnology has been employed in attempts to enhance bone incorporation of dental implants. Often, nanoparticles are applied to the implant surface as particle coatings. However, the same properties that may increase the functionality may also lead to undiscovered negative effects, such as instability of the nanocoating. The aim of this study was to investigate the stability/instability of the nanoparticles using a radiolabeling technique. Materials and Methods: Twenty threaded and turned titanium microimplants were inserted in 10 rats. All 20 implants were coated with nanometer-sized hydroxyapatite (HA) particles. In order to trace the HA nanoparticles, the particles for 16 implants were labeled with calcium 45 ((45)Ca). After 1, 2, 4, and 8 weeks, the implants and surrounding bone were retrieved and analyzed using autoradiography with respect to particle migration from the implant surface. Samples from the brain, liver, thymus, kidney, and blood, as well as wooden shavings from the rats' cages, were also retrieved and analyzed using liquid scintillation counting. Results: The radioactivity representing the localization of 45Ca decreased over time from the vicinity of the implant. The amounts of 45Ca found in the blood and in the rats' excretions decreased with time and corresponded well to each other. After 8 weeks, the only trace of 45Ca was found in the liver. Conclusion: The results indicated that released particles leave the body through the natural cleaning system, and the probability that the nanocoating will assemble in vital organs and thus become a potential biologic risk factor is unlikely. Int J Oral Maxillofac Implants 2011;26:1161-1166
引用
收藏
页码:1161 / 1166
页数:6
相关论文
共 50 条
  • [41] Biomimetic Composite Coatings for Activation of Titanium Implant Surfaces: Methodological Approach and In Vivo Enhanced Osseointegration
    Oltean-Dan, Daniel
    Dogaru, Gabriela-Bombonica
    Jianu, Elena-Mihaela
    Riga, Sorin
    Tomoaia-Cotisel, Maria
    Mocanu, Aurora
    Barbu-Tudoran, Lucian
    Tomoaia, Gheorghe
    MICROMACHINES, 2021, 12 (11)
  • [42] Human Blood Cells Affected by Hydroxyapatite Coated Titanium
    Leice, A.
    Dekhtyar, Y.
    Britzina, N.
    Arabere, L.
    Arhipovich, V.
    14TH NORDIC-BALTIC CONFERENCE ON BIOMEDICAL ENGINEERING AND MEDICAL PHYSICS, 2008, 20 : 45 - +
  • [43] Direct observation of hydroxyapatite nanoparticles in vivo
    Zhou, Wei
    Zheng, Jun
    FRONTIERS OF MANUFACTURING SCIENCE AND MEASURING TECHNOLOGY II, PTS 1 AND 2, 2012, 503-504 : 688 - +
  • [44] Characterization of the aspects of osteoprogenitor cell interactions with physical tetracalcium phosphate anchorage on titanium implant surfaces
    Ko, Chia-Ling
    Chang, Ya-Yuan
    Liou, Cian-Hua
    Chen, Wen-Cheng
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2015, 49 : 7 - 13
  • [45] Biofilm formation on nanostructured hydroxyapatite- coated titanium
    Westas, Emma
    Gillstedt, Martin
    Lonn-Stensrud, Jessica
    Bruzell, Ellen
    Andersson, Martin
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2014, 102 (04) : 1063 - 1070
  • [46] Early bone apposition to hydrophilic and hydrophobic titanium implant surfaces: a histologic and histomorphometric study in minipigs
    Vasak, Christoph
    Busenlechner, Dieter
    Schwarze, Uwe Y.
    Leitner, Herbert F.
    Munoz Guzon, Fernando
    Hefti, Thomas
    Schlottig, Falko
    Gruber, Reinhard
    CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (12) : 1378 - 1385
  • [47] In Vivo Assessment of Silica-coated Titanium Implants for Improved Osseointegration: a Systematic Review
    Santo, Giovanna do Espirito
    Alqualo, Amanda Sardeli
    Amaral, Gustavo Oliva
    de Souza, Amanda
    Garcia-Motta, Homero
    Merlo, Julieta Leticia
    Viegas, Beatriz Louise Mendes
    Prado, Joao Paulo dos Santos
    Sousa, Karolyne dos Santos Jorge
    Zaratin, Rafael Anaya da Silva
    Granito, Renata Neves
    Ribeiro, Daniel Araki
    Cere, Silvia Marcela
    Renno, Ana Claudia
    REGENERATIVE ENGINEERING AND TRANSLATIONAL MEDICINE, 2025,
  • [48] Evaluation of a Novel Calcium Phosphate-Coated Titanium Porous Oxide Implant Surface: A Study in Rabbits
    Poulos, Nicholas M.
    Rodriguez, Nancy A.
    Lee, Jaebum
    Rueggeberg, Frederick A.
    Schuepbach, Peter
    Hall, Jan
    Susin, Cristiano
    Wikesjoe, Ulf M. E.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2011, 26 (04) : 731 - 738
  • [49] Assessing the hierarchical structure of titanium implant surfaces
    Matteson, Jesse L.
    Greenspan, David C.
    Tighe, Timothy B.
    Gilfoy, Nathan
    Stapleton, Joshua J.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2016, 104 (06) : 1083 - 1090
  • [50] Osteogenic Nanofibrous Coated Titanium Implant Results in Enhanced Osseointegration: In Vivo Preliminary Study in a Rabbit Model
    Siddhartha Das
    Sandeep Gurav
    Vivek Soni
    Arvind Ingle
    Bhabani S. Mohanty
    Pradip Chaudhari
    Kiran Bendale
    Kanchan Dholam
    Jayesh R. Bellare
    Tissue Engineering and Regenerative Medicine, 2018, 15 : 231 - 247