摘要
Purpose: Nanotechnology has been employed in attempts to enhance bone incorporation of dental implants. Often, nanoparticles are applied to the implant surface as particle coatings. However, the same properties that may increase the functionality may also lead to undiscovered negative effects, such as instability of the nanocoating. The aim of this study was to investigate the stability/instability of the nanoparticles using a radiolabeling technique. Materials and Methods: Twenty threaded and turned titanium microimplants were inserted in 10 rats. All 20 implants were coated with nanometer-sized hydroxyapatite (HA) particles. In order to trace the HA nanoparticles, the particles for 16 implants were labeled with calcium 45 ((45)Ca). After 1, 2, 4, and 8 weeks, the implants and surrounding bone were retrieved and analyzed using autoradiography with respect to particle migration from the implant surface. Samples from the brain, liver, thymus, kidney, and blood, as well as wooden shavings from the rats' cages, were also retrieved and analyzed using liquid scintillation counting. Results: The radioactivity representing the localization of 45Ca decreased over time from the vicinity of the implant. The amounts of 45Ca found in the blood and in the rats' excretions decreased with time and corresponded well to each other. After 8 weeks, the only trace of 45Ca was found in the liver. Conclusion: The results indicated that released particles leave the body through the natural cleaning system, and the probability that the nanocoating will assemble in vital organs and thus become a potential biologic risk factor is unlikely. Int J Oral Maxillofac Implants 2011;26:1161-1166
引用
收藏
页码:1161 / 1166
页数:6
相关论文
共 50 条
  • [1] The Effect of Implant Surfaces sputter-coated with Hydroxyapatite Target
    Sakai, Takuya
    Okamura, Kazuhiko
    Watazu, Akira
    Teraoka, Kay
    Kido, Hirofumi
    JOURNAL OF HARD TISSUE BIOLOGY, 2013, 22 (01) : 67 - 77
  • [2] In Vivo Comparison of Bone Formation on Titanium Implant Surfaces Coated with Biomimetically Deposited Calcium Phosphate or Electrochemically Deposited Hydroxyapatite
    Yang, Guo-li
    He, Fu-ming
    Song, En
    Hu, Ji-an
    Wang, Xiao-xiang
    Zhao, Shi-fang
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2010, 25 (04) : 669 - 680
  • [3] The Role of Titanium Implant Surface Modification with Hydroxyapatite Nanoparticles in Progressive Early Bone-Implant Fixation In Vivo
    Lin, Audrey
    Wang, Chiachien Jake
    Kelly, James
    Gubbi, Prabhu
    Nishimura, Ichiro
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2009, 24 (05) : 808 - 816
  • [4] Osteoblast response to porous titanium surfaces coated with zincsubstituted hydroxyapatite
    Yang, Fan
    Wen-jing-Dong
    He, Fu-ming
    Xiao-xiang-Wang
    Zhao, Shi-fang
    Yang, Guo-li
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2012, 113 (03): : 313 - 318
  • [5] Osteoblastic cell attachment to hydroxyapatite-coated implant surfaces in vitro
    Chang, YL
    Stanford, CM
    Wefel, JS
    Keller, JC
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 1999, 14 (02) : 239 - 247
  • [6] In Vitro and In Vivo Biocompatibility Studies of a Cast and Coated Titanium Alloy
    Sommer, Ursula
    Laurich, Stephan
    de Azevedo, Lucie
    Viehoff, Katharina
    Wenisch, Sabine
    Thormann, Ulrich
    Alt, Volker
    Heiss, Christian
    Schnettler, Reinhard
    MOLECULES, 2020, 25 (15):
  • [7] The Soft Tissue Immunologic Response to Hydroxyapatite-Coated Transmucosal Implant Surfaces: A Study in Humans
    De Wilde, Elisabeth A. W. J.
    Jimbo, Ryo
    Wennerberg, Ann
    Naito, Yoshihito
    Coucke, Paul
    Bryington, Matthew S.
    Vandeweghe, Stefan
    De Bruyn, Hugo
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 : E65 - E74
  • [8] Osteoblast Attachment on Titanium Coated with Hydroxyapatite by Atomic Layer Deposition
    Kylmaoja, Elina
    Holopainen, Jani
    Abushahba, Faleh
    Ritala, Mikko
    Tuukkanen, Juha
    BIOMOLECULES, 2022, 12 (05)
  • [9] Hydroxyapatite Nanorod-Modified Sand Blasted Titanium Disk for Endosseous Dental Implant Applications
    Park, So Jung
    Kim, Bo Su
    Gupta, Kailash Chandra
    Lee, Dong Yun
    Kang, Inn-Kyu
    TISSUE ENGINEERING AND REGENERATIVE MEDICINE, 2018, 15 (05) : 601 - 614
  • [10] Microgrooves and Microrugosities in Titanium Implant Surfaces: An In Vitro and In Vivo Evaluation
    Gehrke, Sergio Alexandre
    Cavalcanti de Lima, Jose Henrique
    Rodriguez, Fernando
    Luis Calvo-Guirado, Jose
    Aramburu Junior, Jaime
    Perez-Diaz, Leticia
    Mazon, Patricia
    Manuel Aragoneses, Juan
    De Aza, Piedad N.
    MATERIALS, 2019, 12 (08)