Wireless Ion-Selective Electrode Autonomous Sensing System

被引:23
作者
Fay, Cormac [1 ]
Anastasova, Salzitsa [1 ]
Slater, Conor [1 ]
Buda, Sandra Teodora [1 ]
Shepherd, Roderick [2 ]
Corcoran, Brian [1 ]
O'Connor, Noel E. [1 ,3 ]
Wallace, Gordon G. [2 ]
Radu, Aleksandar [1 ]
Diamond, Dermot [1 ]
机构
[1] Dublin City Univ, CLARITY Ctr Sensor Web Technol, Dublin 9, Ireland
[2] Univ Wollongong, Intelligent Polymer Res Inst, ARC Ctr Excellence Electromat Sci, Wollongong, NSW, Australia
[3] Dublin City Univ, Sch Elect Engn, Dublin 9, Ireland
基金
爱尔兰科学基金会;
关键词
Autonomous; environmental monitoring; ion-selective electrode; potentiometry; reference electrode; sensing; water analysis; wireless; PHOSPHATE; SENSOR; CANCER;
D O I
10.1109/JSEN.2011.2122331
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A paradigm shift in sensing methods and principles is required to meet the legislative demands for detecting hazardous substances in the molecular world. This will encompass the development of new sensing technologies capable of performing very selective and sensitive measurements at an acceptable cost, developed by multidisciplinary teams of chemists, engineers and computer scientists to harvest information from a multitude of molecular targets in health, food and within the environment. In this study we present the successful implementation of a low-cost, wireless chemical sensing system that employs a minimum set of components for effective operation. Specifically, our efforts resulted in a wireless, tri-electrode, ISE pH sensor for use in environmental monitoring. Sensor calibration and validated in situ field trials have been carried out and are presented in this paper.
引用
收藏
页码:2374 / 2382
页数:9
相关论文
共 50 条
[31]   Characterization of a new ionophore-based ion-selective electrode for the potentiometric determination of creatinine in urine [J].
Guinovart, Tomas ;
Hernandez-Alonso, Daniel ;
Adriaenssens, Louis ;
Blondeau, Pascal ;
Rius, F. Xavier ;
Ballester, Pablo ;
Andrade, Francisco J. .
BIOSENSORS & BIOELECTRONICS, 2017, 87 :587-592
[32]   Ion-selective electrode for salicylate assay in blood serum [J].
Katsu, T ;
Mori, Y .
TALANTA, 1996, 43 (05) :755-759
[33]   Solid-contact ion-selective electrode with stable internal electrode [J].
Vamvakaki, M ;
Chaniotakis, NA .
ANALYTICA CHIMICA ACTA, 1996, 320 (01) :53-61
[34]   Development and Optimization of an Ion-selective Electrode for Serotonin Detection [J].
Bliem, Christina ;
Fruhmann, Philipp ;
Stoica, Anca-Iulia ;
Kleber, Christoph .
ELECTROANALYSIS, 2017, 29 (06) :1635-1642
[35]   CONSTRUCTION AND EVALUATION OF A NOVEL GLAFENINE ION-SELECTIVE ELECTRODE [J].
AHMED, MA ;
ABBAS, AB .
ANALYTICAL LETTERS, 1995, 28 (01) :13-26
[36]   Cobalt(II) ion-selective electrode with solid contact [J].
Wardak, Cecylia .
CENTRAL EUROPEAN JOURNAL OF CHEMISTRY, 2008, 6 (04) :607-612
[37]   ION-SELECTIVE ELECTRODE FOR QUANTITATIVE DETERMINATION OF BACLOFEN IN PILLS [J].
Nazarov, V. A. ;
Andronchik, K. A. ;
Egorov, V. V. ;
Belyaev, S. A. ;
Yurkshtovich, T. L. .
PHARMACEUTICAL CHEMISTRY JOURNAL, 2011, 45 (06) :374-376
[38]   Calibration procedures for a halide Ion-Selective Electrode array [J].
Baret, E ;
Fabry, P ;
Massart, DL ;
Menardo, C ;
Fraysse, M .
ANALUSIS, 1998, 26 (08) :267-277
[39]   Ion-selective electrode for bismuth(III) in ethylenediamintetraacetate medium [J].
Teixeira, MFD ;
Pinto, AZ ;
Fatibello, O .
TALANTA, 1997, 45 (02) :249-255
[40]   Ion-selective electrode for quantitative determination of baclofen in pills [J].
V. A. Nazarov ;
K. A. Andronchik ;
V. V. Egorov ;
S. A. Belyaev ;
T. L. Yurkshtovich .
Pharmaceutical Chemistry Journal, 2011, 45 :374-376