Optical needle biopsy for multimodal detection of malignant liver tumours
被引:0
|
作者:
Zherebtsov, Evgenii
论文数: 0引用数: 0
h-index: 0
机构:
Orel State Univ, Res & Dev Ctr Biomed Photon, Oryol, Russia
Univ Oulu, Optoelect & Measurement Tech Unit, Oulu, FinlandOrel State Univ, Res & Dev Ctr Biomed Photon, Oryol, Russia
Zherebtsov, Evgenii
[1
,2
]
Potapova, Elena
论文数: 0引用数: 0
h-index: 0
机构:
Orel State Univ, Res & Dev Ctr Biomed Photon, Oryol, RussiaOrel State Univ, Res & Dev Ctr Biomed Photon, Oryol, Russia
Potapova, Elena
[1
]
Valery, Shupletsov
论文数: 0引用数: 0
h-index: 0
机构:
Orel State Univ, Res & Dev Ctr Biomed Photon, Oryol, RussiaOrel State Univ, Res & Dev Ctr Biomed Photon, Oryol, Russia
Valery, Shupletsov
[1
]
Kandurova, Ksenia
论文数: 0引用数: 0
h-index: 0
机构:
Orel State Univ, Res & Dev Ctr Biomed Photon, Oryol, RussiaOrel State Univ, Res & Dev Ctr Biomed Photon, Oryol, Russia
Kandurova, Ksenia
[1
]
Dremin, Viktor
论文数: 0引用数: 0
h-index: 0
机构:
Orel State Univ, Res & Dev Ctr Biomed Photon, Oryol, Russia
Aston Univ, Coll Engn & Phys Sci, Birmingham, W Midlands, EnglandOrel State Univ, Res & Dev Ctr Biomed Photon, Oryol, Russia
Dremin, Viktor
[1
,3
]
Mamoshin, Andrian
论文数: 0引用数: 0
h-index: 0
机构:
Orel State Univ, Res & Dev Ctr Biomed Photon, Oryol, Russia
Orel Reg Clin Hosp, Oryol, RussiaOrel State Univ, Res & Dev Ctr Biomed Photon, Oryol, Russia
Mamoshin, Andrian
[1
,4
]
Dunaev, Andrey
论文数: 0引用数: 0
h-index: 0
机构:
Orel State Univ, Res & Dev Ctr Biomed Photon, Oryol, RussiaOrel State Univ, Res & Dev Ctr Biomed Photon, Oryol, Russia
Dunaev, Andrey
[1
]
机构:
[1] Orel State Univ, Res & Dev Ctr Biomed Photon, Oryol, Russia
[2] Univ Oulu, Optoelect & Measurement Tech Unit, Oulu, Finland
[3] Aston Univ, Coll Engn & Phys Sci, Birmingham, W Midlands, England
Malignant tumours of the liver are one of the most common causes of cancer death worldwide. The presence and type of tumours can be verified only after histological and cytological analysis of a sample obtained during percutaneous needle biopsy. However, the relatively high probability of false-negative results caused by insufficient tissue samples remains a problem. The introduction of real- time methods to navigate the needle during the biopsy can serve as a solution that reduces the number of mistakes. The paper presents the results of measurements in the murine model of hepatocellular carcinoma by a system equipped with fluorescence lifetime and diffuse reflectance channels, as well as a novel needle optical probe compatible with 17.5G standard biopsy needles. The experimental setup developed allowed us to evaluate the parameters of short and slow fluorescence lifetimes, fluorescence intensities and blood oxygen saturation in tissues. We demonstrated that the set of recorded parameters allows us to distinguish the malignant tissue, control liver tissue and metabolically changed liver tissues near the tumour. We suppose that the proposed technique, supported by machine learning, can significantly decrease the rate of false-negative results obtained with percutaneous needle biopsy.