Seismic behavior of concentrically steel braced frames and their use in strengthening of reinforced concrete frames by external application

被引:1
作者
Unal, Alptug [1 ]
Kaltakci, Mevlut Yasar [2 ]
机构
[1] Selcuk Univ, Fac Engn, Dept Civil Engn, Konya, Turkey
[2] Hasan Kalyoncu Univ, Fac Engn, Dept Civil Engn, Gaziantep, Turkey
关键词
concentrically steel braced frames; reinforced concrete frames; design and construction mistakes; pushover analysis; strengthening; BUCKLING-RESTRAINED BRACES; PERFORMANCE; DESIGN; BUILDINGS;
D O I
10.12989/scs.2016.21.4.687
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
There are many studies in the literature conducted on the subject of ensuring earthquake safety of reinforced concrete and steel structures using steel braced frames, but no detailed study concerning individual behavior of steel braced frames under earthquake loads and strengthening of reinforced concrete structures with out-of-plane steel braced frames has been encountered. In this study, in order to evaluate behaviors of "Concentrically Steel Braced Frames" types defined in TEC-2007 under lateral loads, dimensional analysis of Concentrically Steel Braced Frames designed with different scales and dimensions was conducted, the results were controlled according to TEC-2007, and after conducting static pushover analysis, behavior and load capacity of the Concentrically Steel Braced Frames and hinges sequence of the elements constituting the Concentrically Steel Braced Frames were tested. Concentrically Steel Braced Frames that were tested analytically consist of 2 storey and one bay, and are formed as two groups with the scales 1/2 and 1/3. In the study, Concentrically Steel Braced Frames described in TEC-2007 were designed, which are 7 types in total being non-braced, X-braced, V-braced, Lambda-braced, \- braced, /- braced and K-braced. Furthermore, in order to verify accuracy of the analytic studies performed, the 1/2 scaled concentrically steel X-braced frame test element made up of box profiles and 1/3 scaled reinforced concrete frame with insufficient earthquake resistance were tested individually under lateral loads, and test results were compared with the results derived from analytic studies and interpreted. Similar results were obtained from both experimental studies and pushover analyses. According to pushover analysis results, load-carrying capacity of 1/3 scaled reinforced concrete frames increased up to 7,01 times as compared to the non-braced specimen upon strengthening. Results acquired from the study revealed that reinforced concrete buildings which have inadequate seismic capacity can be strengthened quickly, easily and economically by this method without evacuating them.
引用
收藏
页码:687 / 702
页数:16
相关论文
共 50 条
  • [41] Seismic Behavior of FRP-Retrofitted Reinforced Concrete Frames
    Hadigheh, S. A.
    Mahini, S. S.
    Maheri, M. R.
    JOURNAL OF EARTHQUAKE ENGINEERING, 2014, 18 (08) : 1171 - 1197
  • [42] Seismic fragility assessment of reinforced concrete moment frames retrofitted with strongback braced system
    Azandariani, Mojtaba Gorji
    Azandariani, Ali Gorji
    Rousta, Ali Mohammad
    Nia, Hamid Malek
    RESULTS IN ENGINEERING, 2023, 20
  • [43] Seismic Response of Two-Bay Steel Multi-Tiered Concentrically Braced Frames
    Comeau, Christophe
    Cano, Pablo
    Tremblay, Robert
    Imanpour, Ali
    PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON BEHAVIOUR OF STEEL STRUCTURES IN SEISMIC AREAS, STESSA 2022, 2022, 262 : 388 - 395
  • [44] Seismic behavior factors of buckling-restrained braced frames
    Kim, Jinkoo
    Park, Junhee
    Kim, Sang-Dae
    STRUCTURAL ENGINEERING AND MECHANICS, 2009, 33 (03) : 261 - 284
  • [45] Seismic Performance Assessment of Low-Ductility Concentrically Braced Frames
    Sizemore, Joshua G.
    Fahnestock, Larry A.
    Hines, Eric M.
    JOURNAL OF STRUCTURAL ENGINEERING, 2019, 145 (04)
  • [46] Experimental and analytical investigations on seismic behavior of ductile steel knee braced frames
    Zahrai, Seyed Mehdi
    Jalali, Meysam
    STEEL AND COMPOSITE STRUCTURES, 2014, 16 (01) : 1 - 21
  • [47] Behavior of ductile steel X-braced RC frames in seismic zones
    Alberto Godinez-Dominguez, Eber
    Tena-Colunga, Arturo
    EARTHQUAKE ENGINEERING AND ENGINEERING VIBRATION, 2019, 18 (04) : 845 - 869
  • [48] Development and Evaluation of Seismic Retrofit Alternatives for Older Concentrically Braced Frames
    Sen, Andrew D.
    Swatosh, Marsha A.
    Ballard, Ryan
    Sloat, Daniel
    Johnson, Molly M.
    Roeder, Charles W.
    Lehman, Dawn E.
    Berman, Jeffrey W.
    JOURNAL OF STRUCTURAL ENGINEERING, 2017, 143 (05)
  • [49] Brace-to-frame connection modelling effects on seismic loss assessment of steel concentrically-braced frames
    Silva, A.
    Castro, J. M.
    Monteiro, R.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 172
  • [50] APPLICATION OF MAGNETO-RHEOLOGICAL DAMPERS IN CONCENTRICALLY BRACED FRAMES
    Vulcu, C.
    Dubina, D.
    STEEL AND ALUMINIUM STRUCTURES, 2016,