Angiographic and Optical Coherence Tomography Insights Into Bioresorbable Scaffold Thrombosis Single-Center Experience

被引:45
作者
Karanasos, Antonios [1 ]
Van Mieghem, Nicolas [1 ]
van Ditzhuijzen, Nienke [1 ]
Felix, Cordula [1 ]
Daemen, Joost [1 ]
Autar, Anouchska [2 ]
Onuma, Yoshinobu [1 ]
Kurata, Mie [2 ]
Diletti, Roberto [1 ]
Valgimigli, Marco [1 ]
Kauer, Floris [1 ]
van Beusekom, Heleen [2 ]
de Jaegere, Peter [1 ]
Zijlstra, Felix [1 ]
van Geuns, Robert-Jan [1 ]
Regar, Evelyn [1 ]
机构
[1] Erasmus MC, Thoraxctr, Dept Intervent Cardiol, NL-3015 CE Rotterdam, Netherlands
[2] Erasmus MC, Thoraxctr, Dept Expt Cardiol, NL-3015 CE Rotterdam, Netherlands
关键词
bioabsorbable implants; coronary artery disease; drug-eluting stents; tomography; optical coherence; DRUG-ELUTING STENTS; ELEVATION MYOCARDIAL-INFARCTION; VASCULAR SCAFFOLD; NEOINTIMAL COVERAGE; CLINICAL-EVALUATION; OUTCOMES; IMPLANTATION; APPOSITION; DISCONTINUATION; INTERVENTION;
D O I
10.1161/CIRCINTERVENTIONS.114.002369
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-As bioresorbable vascular scaffolds (BVSs) are being increasingly used in complex real-world lesions and populations, BVS thrombosis cases have been reported. We present angiographic and optical coherence tomography (OCT) findings in a series of patients treated in our center for definite bioresorbable scaffold thrombosis. Methods and Results-Up to June 2014, 14 patients presented with definite BVS thrombosis in our center. OCT was performed in 9 patients at the operator's discretion. Angiographic and OCT findings were compared with a control group comprising 15 patients with definite metallic stent thrombosis. In the BVS group, time interval from index procedure to scaffold thrombosis ranged from 0 to 675 days. Incomplete lesion coverage by angiography was identified in 4 of 14 cases, malapposition by OCT in 5 of 9 cases, strut discontinuity in 2 of 9 cases, and underexpansion in 2 of 9 cases. Five patients had discontinued dual antiplatelet therapy, and in 3 of them discontinued dual antiplatelet therapy discontinuation had occurred the week preceding the event. There were no significant differences in angiographic or OCT findings between BVS and metallic stent thrombosis. Conclusions-Suboptimal implantation with incomplete lesion coverage, underexpansion, and malapposition comprises the main pathomechanism for both early and late BVS thrombosis, similar to metallic stent thrombosis. Dual antiplatelet therapy discontinuation seems to also be a secondary contributor in several late events. Our observations suggest that several potential triggers for BVS thrombosis could be avoided.
引用
收藏
页数:9
相关论文
共 29 条
[1]   The ABSORB EXTEND study: preliminary report of the twelve-month clinical outcomes in the first 512 patients enrolled [J].
Abizaid, Alexandre ;
Ribamar Costa, J., Jr. ;
Bartorelli, Antonio L. ;
Whitbourn, Robert ;
van Geuns, Robert Jan ;
Chevalier, Bernard ;
Patel, Tejas ;
Seth, Ashok ;
Stuteville, Marrianne ;
Dorange, Cecile ;
Cheong, Wai-Fung ;
Sudhir, Krishnankutty ;
Serruys, Patrick W. .
EUROINTERVENTION, 2015, 10 (12) :1396-1401
[2]   Combined use of optical coherence tomography and intravascular ultrasound imaging in patients undergoing coronary interventions for stent thrombosis [J].
Alfonso, Fernando ;
Dutary, Jaime ;
Paulo, Manuel ;
Gonzalo, Nieves ;
Perez-Vizcayno, Maria J. ;
Jimenez-Quevedo, Pilar ;
Escaned, Javier ;
Banuelos, Camino ;
Hernandez, Rosana ;
Macaya, Carlos .
HEART, 2012, 98 (16) :1213-1220
[3]   Very late stent thrombosis related to incomplete neointimal coverage or neoatherosclerotic plaque rupture identified by optical coherence tomography imaging [J].
Amabile, Nicolas ;
Souteyrand, Geraud ;
Ghostine, Said ;
Combaret, Nicolas ;
Slama, Michel S. ;
Barber-Chamoux, Nicolas ;
Motreff, Pascal ;
Caussin, Christophe .
EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2014, 15 (01) :24-31
[4]   Percutaneous coronary intervention with everolimus-eluting bioresorbable vascular scaffolds in routine clinical practice: early and midterm outcomes from the European multicentre GHOST-EU registry [J].
Capodanno, Davide ;
Gori, Tommaso ;
Nef, Holger ;
Latib, Azeem ;
Mehilli, Julinda ;
Lesiak, Maciej ;
Caramanno, Giuseppe ;
Naber, Christoph ;
Di Mario, Carlo ;
Colombo, Antonio ;
Capranzano, Piera ;
Wiebe, Jens ;
Araszkiewicz, Aleksander ;
Geraci, Salvatore ;
Pyxaras, Stelios ;
Mattesini, Alessio ;
Naganuma, Toru ;
Muenzel, Thomas ;
Tamburino, Corrado .
EUROINTERVENTION, 2015, 10 (10) :1144-1153
[5]   Intravascular Ultrasound Findings of Early Stent Thrombosis After Primary Percutaneous Intervention in Acute Myocardial Infarction A Harmonizing Outcomes With Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) Substudy [J].
Choi, So-Yeon ;
Witzenbichler, Bernhard ;
Maehara, Akiko ;
Lansky, Alexandra J. ;
Guagliumi, Giulio ;
Brodie, Bruce ;
Kellett, Mirle A., Jr. ;
Dressler, Ovidiu ;
Parise, Helen ;
Mehran, Roxana ;
Dangas, George D. ;
Mintz, Gary S. ;
Stone, Gregg W. .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (03) :239-247
[6]   Impact of incomplete stent apposition on long-term clinical outcome after drug-eluting stent implantation [J].
Cook, Stephane ;
Eshtehardi, Parham ;
Kalesan, Bindu ;
Raeber, Lorenz ;
Wenaweser, Peter ;
Togni, Mario ;
Moschovitis, Aris ;
Vogel, Rolf ;
Seiler, Christian ;
Eberli, Franz R. ;
Luescher, Thomas ;
Meier, Bernhard ;
Jueni, Peter ;
Windecker, Stephan .
EUROPEAN HEART JOURNAL, 2012, 33 (11) :1334-1343
[7]   Clinical end points in coronary stent trials - A case for standardized definitions [J].
Cutlip, Donald E. ;
Windecker, Stephan ;
Mehran, Roxana ;
Boam, Ashley ;
Cohen, David J. ;
van Es, Gerrit-Anne ;
Steg, P. Gabriel ;
Morel, Marie-angele ;
Mauri, Laura ;
Vranckx, Pascal ;
McFadden, Eugene ;
Lansky, Alexandra ;
Hamon, Martial ;
Krucoff, Mitchell W. ;
Serruys, Patrick W. .
CIRCULATION, 2007, 115 (17) :2344-2351
[8]   Everolimus-eluting bioresorbable vascular scaffolds for treatment of patients presenting with ST-segment elevation myocardial infarction: BVS STEMI first study [J].
Diletti, Roberto ;
Karanasos, Antonios ;
Muramatsu, Takashi ;
Nakatani, Shimpei ;
Van Mieghem, Nicolas M. ;
Onuma, Yoshinobu ;
Nauta, Sjoerd T. ;
Ishibashi, Yuki ;
Lenzen, Mattie J. ;
Schultz, Carl ;
Regar, Evelyn ;
de Jaegere, Peter P. ;
Serruys, Patrick W. ;
Zijlstra, Felix ;
van Geuns, Robert Jan .
EUROPEAN HEART JOURNAL, 2014, 35 (12) :777-+
[9]   Incomplete Stent Apposition Causes High Shear Flow Disturbances and Delay in Neointimal Coverage as a Function of Strut to Wall Detachment Distance Implications for the Management of Incomplete Stent Apposition [J].
Foin, Nicolas ;
Gutierrez-Chico, Juan Luis ;
Nakatani, Shimpei ;
Torii, Ryo ;
Bourantas, Christos V. ;
Sen, Sayan ;
Nijjer, Sukhjinder ;
Petraco, Ricardo ;
Kousera, Chrysa ;
Ghione, Matteo ;
Onuma, Yoshinobu ;
Garcia-Garcia, Hector M. ;
Francis, Darrel P. ;
Wong, Philip ;
Di Mario, Carlo ;
Davies, Justin E. ;
Serruys, Patrick W. .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (02) :180-189
[10]   Prasugrel Plus Aspirin Beyond 12 Months Is Associated With Improved Outcomes After Taxus Liberte Paclitaxel-Eluting Coronary Stent Placement [J].
Garratt, Kirk N. ;
Weaver, W. Douglas ;
Jenkins, Ronald G. ;
Pow, Thomas K. ;
Mauri, Laura ;
Kereiakes, Dean J. ;
Winters, Kenneth J. ;
Christen, Thomas ;
Allocco, Dominic J. ;
Lee, David P. .
CIRCULATION, 2015, 131 (01) :62-+