Multichannel data acquisition system for mapping the electrical activity of the heart

被引:16
作者
Ciaccio, EJ
Saltman, AE
Hernandez, OM
Bornholdt, RJ
Coromilas, J
机构
[1] Columbia Univ Coll Phys & Surg, Dept Pharmacol, New York, NY 10032 USA
[2] Columbia Univ Coll Phys & Surg, Dept Biomed Engn, New York, NY 10032 USA
[3] Columbia Univ Coll Phys & Surg, Dept Med, New York, NY 10032 USA
[4] Univ Massachusetts, Dept Surg, Amherst, MA 01003 USA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2005年 / 28卷 / 08期
关键词
acquisition; data; electrocardiology; mapping; multichannel; signals;
D O I
10.1111/j.1540-8159.2005.00167.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Details of the electrical conduction pattern of the heart are revealed to the electrophysiologist when multichannel data are used for activation mapping. Commercial electronic systems are available for simultaneous acquisition of many surface electrograms; however, the cost of these systems may be prohibitive and they can be mostly inflexible for adaptation to other research projects. Furthermore, the hardware and software design is often proprietary. In this article we describe the in-house design and implementation of a 320-multichannel acquisition system for animal electrophysiologic research. Method and Results: Several modules comprise this system. The multichannel data are first preprocessed by amplification, filtering, and analog multiplexing. An algorithm for automatic adjustment of signal gains is implemented to maximize the voltage resolution and minimize noise pickup. Signals are then digitized, and sequenced to order the multichannel data and to add markers required for analysis. The digital data are streamed to archival storage media. Additionally, the electrocardiogram (ECG), blood pressure, and stimulus channel signals are stored simultaneously. Selected signals are then displayed in real-time for measurement and analysis and as a check of the system integrity. Examples of multielectrode arrays and surface recordings are provided. Costs for building such a system are estimated. Conclusions: Multichannel data acquisition systems that are designed and constructed in-house have several advantages over turnkey commercial systems, including the potential for considerable cost savings, flexibility in acquiring data, and the ability to subsequently add additional components.
引用
收藏
页码:826 / 838
页数:13
相关论文
共 20 条
  • [1] Optically imaging cardiac activation with a laser system
    Bove, RT
    Dillon, SM
    [J]. IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1998, 17 (01): : 84 - 94
  • [2] Ciaccio EJ, 2000, CIRCULATION, V102, P464
  • [3] Analysis and acquisition at multichannel data in electrocardiology
    Ciaccio, EJ
    [J]. IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1998, 17 (01): : 32 - 33
  • [4] Dynamic changes in electrogram morphology at functional lines of block in reentrant circuits during ventricular tachycardia in the infarcted canine heart: A new method to localize reentrant circuits from electrogram features using adaptive template matching
    Ciaccio, EJ
    Scheinman, MM
    Fridman, V
    Schmitt, H
    Coromilas, J
    Wit, AL
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1999, 10 (02) : 194 - 213
  • [5] Static relationship of cycle length to reentrant circuit geometry
    Ciaccio, EJ
    Costeas, C
    Coromilas, J
    Wit, AL
    [J]. CIRCULATION, 2001, 104 (16) : 1946 - 1951
  • [6] Relationship between sinus rhythm activation and the reentrant ventricular tachycardia isthmus
    Ciaccio, EJ
    Tosti, AC
    Scheinman, MM
    [J]. CIRCULATION, 2001, 104 (05) : 613 - 619
  • [7] Prediction of the location and time of spontaneous termination of reentrant ventricular tachycardia for radiofrequency catheter ablation therapy
    Ciaccio, EJ
    Wit, AL
    Scheinman, MM
    [J]. JOURNAL OF ELECTROCARDIOLOGY, 1995, 28 : 165 - 173
  • [8] Voltage and activation mapping - How the recording technique affects the outcome of catheter ablation procedures in patients with congenital heart disease
    de Groot, NMS
    Schalij, MJ
    Zeppenfeld, K
    Blom, NA
    Van der Velde, ET
    Van der Wall, EE
    [J]. CIRCULATION, 2003, 108 (17) : 2099 - 2106
  • [9] A system for in-vivo cardiac optical mapping
    Dillon, SM
    Kerner, TE
    Hoffman, J
    Menz, V
    Li, KS
    Michele, JJ
    [J]. IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1998, 17 (01): : 95 - 108
  • [10] INFLUENCES OF ANISOTROPIC TISSUE STRUCTURE ON REENTRANT CIRCUITS IN THE EPICARDIAL BORDER ZONE OF SUBACUTE CANINE INFARCTS
    DILLON, SM
    ALLESSIE, MA
    URSELL, PC
    WIT, AL
    [J]. CIRCULATION RESEARCH, 1988, 63 (01) : 182 - 206