Deep eutectic solvent based advance microextraction method for determination of aluminum in water and food samples: Multivariate study

被引:79
作者
Panhwar, Abdul Haleem [1 ,2 ]
Tuzen, Mustafa [1 ,3 ]
Kazi, Tasneem Gul [2 ]
机构
[1] Gaziosmanpasa Univ, Fac Sci & Arts, Chem Dept, TR-60250 Tokat, Turkey
[2] Univ Sindh, Natl Ctr Excellence Analyt Chem, Jamshoro 76080, Pakistan
[3] King Fahd Univ Petr & Minerals, Res Inst, Ctr Environm & Water, Dhahran 31261, Saudi Arabia
关键词
Aluminum; Deep eutectic solvent; Ultrasonication; Dispersive liquid microextraction; Electrothennal atomic absorption spectrometry; ATOMIC-ABSORPTION-SPECTROMETRY; CLOUD POINT EXTRACTION; SIMULTANEOUS SPECTROPHOTOMETRIC DETERMINATION; TRACE ALUMINUM; SOLID-PHASE; PRECONCENTRATION; COMPLEXATION; SEPARATION; ACID; AL3+;
D O I
10.1016/j.talanta.2017.09.079
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Preconcentration of aluminum Al3+ was carried out by a novel deep eutectic solvent based ultrasound-assisted liquid phase microextraction (DES-UALPME) method. The deep eutectic solvents (DESs), a green solvent was first time used for enrichment and quantification of very low concentration of Al3+ in water and food samples, prior to analysed by electrothermal atomic absorption spectrometry (ETAAS). In present method it was observed that % recovery of Al-8-hydroxyquinoline chelates efficiently extracted by DES solvent. Pre-enrichment factor and limit of detection were observed to be 50, and 0.032 tig L-1, respectively. Developed procedure was validated with the CRM (SLRS-5 river water) of Al and a good agreement was observed in results of measured value to the certified value. The RSD was calculated as 3.3%. The presented procedure was successfully carried out to different water and food samples.
引用
收藏
页码:588 / 593
页数:6
相关论文
共 36 条
[1]   Combination of ionic liquid-based dispersive liquid-liquid micro-extraction with stopped-flow spectrofluorometry for the pre-concentration and determination of aluminum in natural waters, fruit juice and food samples [J].
Abdolmohammad-Zadeh, H. ;
Sadeghi, G. H. .
TALANTA, 2010, 81 (03) :778-785
[2]   Flow-injection solvent extraction with and without phase separation - Fluorimetric determination of aluminium in water [J].
Alonso, A ;
Almendral, MJ ;
Porras, MJ ;
Curto, Y ;
de Maria, CG .
ANALYTICA CHIMICA ACTA, 2001, 447 (1-2) :211-217
[3]  
[Anonymous], 2018, Guidelines for Drinking Water Quality
[4]   Temperature controlled ionic liquid-based dispersive micro-extraction using two ligands, for determination of aluminium in scalp hair samples of Alzheimer's patients: A multivariate study [J].
Arain, Mariam S. ;
Arain, Salma A. ;
Kazi, Tasneem G. ;
Afridi, Hassan I. ;
Ali, Jamshaid ;
Naeemulllah ;
Arain, Sadaf S. ;
Brahman, Kapil Dev ;
Mughal, Moina Akhtar .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2015, 137 :877-885
[5]   Micelle-mediated extraction for simultaneous spectrophotometric determination of aluminum and beryllium using mean centering of ratio spectra [J].
Bahram, Morteza ;
Madrakian, Tayyebeh ;
Bozorgzadeh, Elaheh ;
Afkhami, Abbas .
TALANTA, 2007, 72 (02) :408-414
[6]   Exploitation of the complexation reaction of ortho-dihydroxylated anthocyanins with aluminum(III) for their quantitative spectrophotometric determination in edible sources [J].
Bernal, Freddy A. ;
Orduz-Diaz, Luisa L. ;
Coy-Barrera, Ericsson .
FOOD CHEMISTRY, 2015, 185 :84-89
[7]   Evaluation of alcohol-based deep eutectic solvent in extraction and determination of flavonoids with response surface methodology optimization [J].
Bi, Wentao ;
Tian, Minglei ;
Row, Kyung Ho .
JOURNAL OF CHROMATOGRAPHY A, 2013, 1285 :22-30
[8]   Prolonged exposure to low levels of aluminum leads to changes associated with brain aging and neurodegeneration [J].
Bondy, Stephen C. .
TOXICOLOGY, 2014, 315 :1-7
[9]   Preconcentration, separation and spectrophotometric determination of aluminium(III) in water samples and dialysis concentrates at trace levels with 8-hydroxyquinoline-cobalt(II) coprecipitation system [J].
Bulut, Volkan Numan ;
Arslan, Deniz ;
Ozdes, Duygu ;
Soylak, Mustafa ;
Tufekci, Mehmet .
JOURNAL OF HAZARDOUS MATERIALS, 2010, 182 (1-3) :331-336
[10]  
Cabezuelo ABS, 1998, ANALYST, V123, P865