Performance Evaluation of the New HIV-1 Quantification Assay, Xpert HIV-1 Viral Load, on a Wide Panel of HIV-1 Variants

被引:31
作者
Gueudin, Marie [1 ,2 ]
Baron, Adeline [1 ]
Alessandri-Gradt, Elodie [1 ,2 ]
Lemee, Veronique [1 ]
Mourez, Thomas [1 ,2 ]
Etienne, Manuel [2 ,3 ]
Plantier, Jean-Christophe [1 ,2 ]
机构
[1] CHU Rouen, Hop Charles Nicolle, Lab Virol Associe Ctr Natl Reference VIH, Dept Microbiol, Rouen, France
[2] Univ Rouen, Inst Rech & Innovat Biomed, Fac Med Pharm, GRAM,Equipe Accueil 2656, Rouen, France
[3] CHU Rouen, Hop Charles Nicolle, COREVIH Haute Normandie, Rouen, France
关键词
HIV viral load; GeneXpert; genetic diversity; ABBOTT REALTIME HIV-1; QUANTITATIVE PCR; RNA; V2.0;
D O I
10.1097/QAI.0000000000001003
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Objective:To evaluate the quantification performance of the new Cepheid GeneXpert HIV-1 viral load assay, on a wide panel of HIV-1 variants.Methods:Clinical performance was evaluated relative to the Abbott RealTime HIV-1 assay on 285 HIV-1 seropositive samples selected to cover the assays quantification range (40 copies/mL-10,000,000 copies/mL), and included RNA undetectable or detected seropositive samples. The panel comprised 120 subtype B, 150 non-B, and 15 nontypable clinical samples; serial dilutions of 18 viral supernatants representative of the divergent viruses of HIV-1 groups N, O, and P were also tested.Results:Based on samples selected according to the Abbott assay viral loads (VL), the Cepheid assay detected or quantified 222/285 (78%) samples and the Abbott assay 240/285 (84%). Xpert yielded VLs for 162 (76%) of the 213 quantifiable samples with Abbott. This difference corresponded to 51 samples with VL >40 copies/mL by the Abbott assay (all below 200 copies/mL) but detected (n = 40) or undetectable (n = 11) by the Cepheid assay. VL of samples quantifiable by both assays (n = 162) showed very strong correlation, with a Spearman correlation coefficient of 0.985 and a Bland-Altman's mean of differences of -0.01. Performance for quantification of the non-M samples showed very good correlation, with significantly higher values with Cepheid for the group N and 2 group O samples.Conclusions:Our study showed that the Xpert HIV-1 VL assay offered very good performance for detection and quantification of the current HIV-1 genetic diversity; differences reported at the threshold could be an issue and requires further evaluations. The practicability of this new assay makes it suitable for low-income countries, where it could facilitate and improve follow-up of patients, as well as for high-income regions.
引用
收藏
页码:521 / 526
页数:6
相关论文
共 15 条
[1]   HIV-1 Load Comparison Using Four Commercial Real-Time Assays [J].
Bourlet, Thomas ;
Signori-Schmuck, Anne ;
Roche, Laurent ;
Icard, Vinca ;
Saoudin, Henia ;
Trabaud, Mary-Anne ;
Tardy, Jean-Claude ;
Morand, Patrice ;
Pozzetto, Bruno ;
Ecochard, Rene ;
Andre, Patrice .
JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (01) :292-297
[2]   Commentary: The monitoring of adults and children on antiretroviral therapy in the 2013 WHO consolidated ARV guidelines [J].
Essajee, Shaffiq ;
Kumarasamy, Nagalingeswaran .
AIDS, 2014, 28 :S147-S149
[3]   Comparative evaluation of the Artus HIV-1 QS-RGQ assay and the Abbott RealTime HIV-1 assay for the quantification of HIV-1 RNA in plasma [J].
Garcia-Diaz, Ana ;
Labbett, Wendy ;
Clewley, Gillian S. ;
Guerrero-Ramos, Alvaro ;
Geretti, Anna Maria .
JOURNAL OF CLINICAL VIROLOGY, 2013, 57 (01) :66-69
[4]   A New Real-Time Quantitative PCR for Diagnosis and Monitoring of HIV-1 Group O Infection [J].
Gueudin, Marie ;
Leoz, Marie ;
Lemee, Veronique ;
De Oliveira, Fabienne ;
Vessiere, Aurelia ;
Kfutwah, Anfumbom ;
Plantier, Jean-Christophe .
JOURNAL OF CLINICAL MICROBIOLOGY, 2012, 50 (03) :831-836
[5]   Comparative performance of the new Aptima HIV-1 Quant Dx assay with three commercial PCR-based HIV-1 RNA quantitation assays [J].
Hopkins, Mark ;
Hau, Sarah ;
Tiernan, Caroline ;
Papadimitropoulos, Athanasios ;
Chawla, Anu ;
Beloukas, Apostolos ;
Geretti, Anna Maria .
JOURNAL OF CLINICAL VIROLOGY, 2015, 69 :56-62
[6]   Comparative Evaluation of the ExaVir Load Version 3 Reverse Transcriptase Assay for Measurement of Human Immunodeficiency Virus Type 1 Plasma Load [J].
Labbett, Wendy ;
Garcia-Diaz, Ana ;
Fox, Zoe ;
Clewley, Gillian S. ;
Fernandez, Thomas ;
Johnson, Margaret ;
Geretti, Anna Maria .
JOURNAL OF CLINICAL MICROBIOLOGY, 2009, 47 (10) :3266-3270
[7]   A cohort study of treatment-experienced HIV-1-infected patients treated with raltegravir: factors associated with virological response and mutations selected at failure [J].
Marcelin, Anne-Genevieve ;
Delaugerre, Constance ;
Beaudoux, Celine ;
Descamps, Diane ;
Morand-Joubert, Laurence ;
Amiel, Corinne ;
Schneider, Veronique ;
Ferre, Virginie ;
Izopet, Jacques ;
Si-Mohamed, Ali ;
Maillard, Anne ;
Henquell, Cecile ;
Desbois, Delphine ;
Lazrek, Mouna ;
Signori-Schmuck, Anne ;
Rogez, Sylvie ;
Yerly, Sabine ;
Trabaud, Mary-Anne ;
Plantier, Jean-Christophe ;
Fourati, Slim ;
Houssaini, Allal ;
Masquelier, Bernard ;
Calvez, Vincent ;
Flandre, Philippe .
INTERNATIONAL JOURNAL OF ANTIMICROBIAL AGENTS, 2013, 42 (01) :42-47
[8]   Evaluation of the RealTime HIV-1, Xpert HIV-1, and Aptima HIV-1 Quant Dx Assays in Comparison to the NucliSens EasyQ HIV-1 v2.0 Assay for Quantification of HIV-1 Viral Load [J].
Mor, Orna ;
Gozlan, Yael ;
Wax, Marina ;
Mileguir, Fernando ;
Rakovsky, Avia ;
Noy, Bina ;
Mendelson, Ella ;
Levy, Itzchak .
JOURNAL OF CLINICAL MICROBIOLOGY, 2015, 53 (11) :3458-3465
[9]   Comparison of the bioMerieux NucliSENS EasyQ HIV-1 v2.0-HIV-1 RNA quantification assay versus Abbott RealTime HIV-1 and Roche Cobas TaqMan HIV-1 v2.0 on current epidemic HIV-1 variants [J].
Mourez, Thomas ;
Delaugerre, Constance ;
Vray, Muriel ;
Lemee, Veronique ;
Simon, Francois ;
Plantier, Jean-Christophe .
JOURNAL OF CLINICAL VIROLOGY, 2015, 71 :76-81
[10]   Non-M Variants of Human Immunodeficiency Virus Type 1 [J].
Mourez, Thomas ;
Simon, Francois ;
Plantier, Jean-Christophe .
CLINICAL MICROBIOLOGY REVIEWS, 2013, 26 (03) :448-461