Experimental investigation on thermal performance and fluid flow characteristics in circular cylindrical tube with circular perforated ring inserts

被引:46
作者
Kumar, Alok [1 ]
Chamoli, Sunil [2 ]
Kumar, Manoj [2 ]
Singh, Satyendra [3 ]
机构
[1] Uttarakhand Tech Univ, TULAS Inst, Dept Mech Engn, Dehra Dun 248197, Uttarakhand, India
[2] DIT Univ Dehradun, Dept Mech Engn, Dehra Dun 248009, Uttarakhand, India
[3] Uttarakhand Tech Univ, BTKIT Dwarahat, Dept Mech Engn, Dehra Dun 263653, Uttarakhand, India
关键词
Heat transfer; Friction factor; Thermal performance factor; Circular perforated ring; HEAT-TRANSFER ENHANCEMENT; FRICTION FACTOR CORRELATIONS; TRANSFER BEHAVIORS; TURBULENT-FLOW; CONICAL-RING; ROUND TUBE; DUCT;
D O I
10.1016/j.expthermflusci.2016.07.002
中图分类号
O414.1 [热力学];
学科分类号
摘要
Heat transfer enhancement by creating turbulence in the physical behavior of fluid flow inside the heat exchanger tube has become a really interesting area for the researchers in order to reduce the size and cost of the involving equipment especially in heat exchangers. Though very significant results are achieved lower range of Reynolds number, but still research is being carried out for the higher range. In this experimental study the effect of circular perforated ring (CPR) insert on heat transfer, friction factor and thermal performance of the heat exchanger tube is evaluated. The different parameters used for the experimentation include, fixed thickness ratio (t/D) of PCD i.e. 0.0075, diameter ratios (d/D = 0.6, 0.7 & 0.8), pitch ratios (l/D = 1) and perforation index (P-A/T-A = 8%, 16% & 24%). The experiments are conducted in the range of flow varying between 6500 and 23,000 Reynolds numbers. The experimentation is carried out in the test section of 1.4 m length with a hydraulic diameter (D) of 68 mm. The test section was heated with constant heat flux of 1000 W/m(2) with the help of a variable voltage transformer. On experimentation, it is found that, there is about 4 times augmentation in heat transfer in case of PI = 8% & DR = 0.6 and 1.47 times improvement in thermal performance factor for PI = 24% and DR = 0.8 as compared to smooth tube heat exchangers. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:168 / 174
页数:7
相关论文
共 30 条
[1]   Enhancement and Prediction of Heat Transfer Rate in Turbulent Flow Through Tube With Perforated Twisted Tape Inserts: A New Correlation [J].
Ahamed, J. U. ;
Wazed, M. A. ;
Ahmed, S. ;
Nukman, Y. ;
Ya, T. M. Y. S. Tuan ;
Sarkar, M. A. R. .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2011, 133 (04)
[2]   Heat transfer enhancement in a tube with twisted tape inserts placed separately from the tube wall [J].
Bas, Halit ;
Ozceyhan, Veysel .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2012, 41 :51-58
[3]   Performance assessment in a heat exchanger tube fitted with double counter twisted tape inserts [J].
Bhuiya, M. M. K. ;
Sayem, A. S. M. ;
Islam, M. ;
Chowdhury, M. S. U. ;
Shahabuddin, M. .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2014, 50 :25-33
[4]   Thermal characteristics in a heat exchanger tube fitted with triple twisted tape inserts [J].
Bhuiya, M. M. K. ;
Chowdhury, M. S. U. ;
Shahabuddin, M. ;
Saha, M. ;
Memon, L. A. .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2013, 48 :124-132
[5]   Heat transfer and friction factor characteristics in turbulent flow through a tube fitted with perforated twisted tape inserts [J].
Bhuiya, M. M. K. ;
Chowdhury, M. S. U. ;
Saha, M. ;
Islam, M. T. .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2013, 46 :49-57
[6]   Heat transfer and pressure drop in tube with broken twisted tape insert [J].
Chang, Shyy Woei ;
Yang, Tsun Lirng ;
Liou, Jin Shuen .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2007, 32 (02) :489-501
[7]   Experimental investigation of heat transfer and friction characteristics in a circular tube fitted with V-nozzle turbulators [J].
Eiamsa-ard, S. ;
Promvonge, P. .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2006, 33 (05) :591-600
[8]   Heat transfer augmentation by helically twisted tapes as swirl and turbulence promoters [J].
Eiamsa-ard, S. ;
Yongsiri, K. ;
Nanan, K. ;
Thianpong, C. .
CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2012, 60 :42-48
[9]   Influence of combined non-uniform wire coil and twisted tape inserts on thermal performance characteristics [J].
Eiamsa-ard, S. ;
Nivesrangsan, P. ;
Chokphoemphun, S. ;
Promvonge, P. .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2010, 37 (07) :850-856
[10]   Thermohydraulics of Turbulent Flow Through Heat Exchanger Tubes Fitted with Circular-rings and Twisted Tapes [J].
Eiamsa-ard, Smith ;
Kongkaitpaiboon, Vichan ;
Nanan, Kwanchai .
CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2013, 21 (06) :585-593