Fundamental studies on electrokinetic chromatography with PEGylated phospholipid micelles

被引:7
|
作者
Kitagawa, Fumihiko [1 ]
Hasegawa, Takayuki [1 ]
Taji, Hirorni [2 ]
Onoue, Satomi [3 ]
Tsuda, Yoshiko [2 ]
Otsuka, Koji [1 ]
机构
[1] Kyoto Univ, Grad Sch Engn, Dept Chem Mat, Nishikyo Ku, Kyoto 6158510, Japan
[2] Pfizer Japan Inc, Nagoya Labs, Aichi 4702393, Japan
[3] Univ Shizuoka, Sch Pharmaceut Sci, Shizuoka 4228526, Japan
关键词
D O I
10.2116/analsci.24.155
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, micelles prepared from distearoylphosphatidylethanolamine with covalently attached poly(ethylene) glycol) (PEG) of molecular weight 2000 (DSPE-PEG-2000) were employed in micellar electrokinetic chromatography (MEKC) as pseudostationary phases. Since DSPE-PEG-2000 contains long hydrophobic alkyl chains, an anionic phosphate group, and hydrophilic PEG chains, the prepared micelles are expected to provide a characteristic retention behavior for both neutral and ionic compounds. As a typical example, a baseline separation of phenol and 2-naphthol was successfully achieved by using the DSPE-PEG-2000 micelles as a background electrolyte for MEKC such success clearly shows that the micelles can retain electrically neutral compounds. The MEKC separations of anionic and cationic compounds with a DSPE-PEG-2000 micellar solution and the enantioseparation of binaphthyl compounds with mixed micelles containing bile salt are also discussed.
引用
收藏
页码:155 / 159
页数:5
相关论文
共 50 条
  • [21] MICROEMULSION ELECTROKINETIC CHROMATOGRAPHY - COMPARISON WITH MICELLAR ELECTROKINETIC CHROMATOGRAPHY
    TERABE, S
    MATSUBARA, N
    ISHIHAMA, Y
    OKADA, Y
    JOURNAL OF CHROMATOGRAPHY, 1992, 608 (1-2): : 23 - 29
  • [22] Separation and on-line preconcentration by sweeping of charged analytes in electrokinetic chromatography with nonionic micelles
    Monton, MRN
    Quirino, JP
    Otsuka, K
    Terabe, S
    JOURNAL OF CHROMATOGRAPHY A, 2001, 939 (1-2) : 99 - 108
  • [23] Studies on the analysis of environmental pollutants by micellar electrokinetic chromatography
    Takeda, S
    BUNSEKI KAGAKU, 1999, 48 (05) : 523 - 524
  • [24] Pegylated Phospholipid Micelles Induce Endoplasmic Reticulum-Dependent Apoptosis of Cancer Cells but not Normal Cells
    Wang, Jing
    Fang, Xiaocui
    Liang, Wei
    ACS NANO, 2012, 6 (06) : 5018 - 5030
  • [25] Color stabilization of cyanidin-3-glucoside-based dyes by encapsulation with biocompatible PEGylated phospholipid micelles
    Cruz, Luis
    Basilio, Nuno
    de Freitas, Victor
    DYES AND PIGMENTS, 2020, 181 (181)
  • [26] Micelles of phospholipid mixtures
    Sprik, R
    Wegdam, GH
    Ge, MT
    Freed, JH
    SPECTROSCOPY OF BIOLOGICAL MOLECULES: NEW DIRECTIONS, 1999, : 369 - 370
  • [27] Electrokinetic chromatography
    Quirino, JP
    Terabe, S
    JOURNAL OF CHROMATOGRAPHY A, 1999, 856 (1-2) : 465 - 482
  • [28] Quantitative structure-activity relationships studies with micellar electrokinetic chromatography - Influence of surfactant type and mixed micelles on estimation of hydrophobicity and bioavailability
    Yang, SY
    Bumgarner, JG
    Kruk, LFR
    Khaledi, MG
    JOURNAL OF CHROMATOGRAPHY A, 1996, 721 (02) : 323 - 335
  • [29] Separation and selectivity of benzophenones in micellar electrokinetic chromatography using sodium dodecyl sulfate micelles or sodium cholate modified mixed micelles
    Lin, CE
    Chen, MJ
    JOURNAL OF CHROMATOGRAPHY A, 2001, 923 (1-2) : 241 - 248
  • [30] Separation and selectivity in micellar electrokinetic chromatography using sodium dodecyl sulfate micelles or Tween 20-modified mixed micelles
    Wang, M
    Wu, D
    Yao, Q
    Shen, XY
    ANALYTICA CHIMICA ACTA, 2004, 519 (01) : 73 - 78