Cerebral monitoring by means of oximetry and somatosensory evoked potentials during carotid endarterectomy

被引:79
作者
Cho, H
Nemoto, EM
Yonas, H
Balzer, J
Sclabassi, RJ
机构
[1] Univ Pittsburgh, Sch Med, Dept Neurol Surg, Pittsburgh, PA 15261 USA
[2] Univ Pittsburgh, Sch Med, Ctr Clin Neurophysiol, Pittsburgh, PA 15261 USA
[3] Korea Univ Hosp, Dept Anesthesiol, Seoul, South Korea
关键词
carotid endarterectomy; cerebral oximetry; somatosensory evoked potentials;
D O I
10.3171/jns.1998.89.4.0533
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. Cerebral ischemia that occurs during carotid endarterectomy is commonly monitored by means of somatosensory evoked potentials (SSEPs) and electroencephalography (EEG). The authors conducted this study to determine whether cerebral ischemia could also be reliably detected by cerebral oximetry. Methods. Twenty-nine patients who underwent carotid endarterectomy were monitored by means of SSEPs, EEG, and cerebral oximetry with a model NIR0500 (20 patients) or INVOS3100A (nine patients) oximeter. Changes in amplitude of SSEPs were graded as follows: 0, no change; 1, decrease of less than 50%; 2, decrease of greater than 50%; and 3, 100% decrease. As measured with the NIR0500 oximeter, closing the common ca ro-tid artery decreased mean oxyhemoglobin levels twice as much (p < 0.005) in the group with SSEPs of 1 to 3 (- 13.11 +/- 5.59 mu M [mean +/- standard deviation], 12 patients) as in the group with SSEPs of 0 (-6.22 +/- 5.59 mu M, eight patients). The rise in deoxyhemoglobin was also greater (p < 0.05). Two of nine patients monitored with the INVOS3100A oximeter had SSEPs of 1 and 3, and their regional saturation of oxygen (rSO(2)) values fell by -11.50 and -11.51, respectively. In the remaining seven patients with SSEPs of 0, the rSO(2) ranged between -2.00 and -6.10 with no overlap with the group with SSEPs of 1 to 3. The increase in oxyhemoglobin monitored using the NIR0500 oximeter and rSO(2) monitored using the INVOS3100A machine after opening the external carotid artery was less than that seen after opening the internal carotid artery. Both types of oximeters could detect cerebral ischemia but whereas false negatives occurred with the NIR0500, none was observed with the INVOS3100A. Extracranial contamination was also four times less frequent with the INVOS3100A than with the NIR0500 monitor. Conclusions. The results indicate that at least as measured with the INVOS3100A instrument, a decrease in rSO(2) of - 10 or more or a decrease below an rSO(2) of 50 is indicative of cerebral ischemia of sufficient severity to decrease the amplitude of SSEPs.
引用
收藏
页码:533 / 538
页数:6
相关论文
共 15 条
[1]   Combined transcranial Doppler and electrophysiologic monitoring for carotid endarterectomy [J].
Fiori, L ;
Parenti, G ;
Marconi, F .
JOURNAL OF NEUROSURGICAL ANESTHESIOLOGY, 1997, 9 (01) :11-16
[2]   Failure of the INVOS 3100 cerebral oximeter to detect complete absence of cerebral blood flow [J].
Gomersall, CD ;
Joynt, GM ;
Gin, T ;
Freebairn, RC ;
Stewart, IET .
CRITICAL CARE MEDICINE, 1997, 25 (07) :1252-1254
[3]   NONINVASIVE CEREBRAL OPTICAL SPECTROSCOPY - DEPTH-RESOLVED MEASUREMENTS OF CEREBRAL HEMODYNAMICS USING INDOCYANINE GREEN [J].
HONGO, K ;
KOBAYASHI, S ;
OKUDERA, H ;
HOKAMA, M ;
NAKAGAWA, F .
NEUROLOGICAL RESEARCH, 1995, 17 (02) :89-93
[4]  
HORSCH S, 1990, J CARDIOVASC SURG, V31, P599
[5]   AN OBSERVATIONAL STUDY OF NEAR-INFRARED SPECTROSCOPY DURING CAROTID ENDARTERECTOMY [J].
KIRKPATRICK, PJ ;
SMIELEWSKI, P ;
WHITFIELD, PC ;
CZOSNYKA, M ;
MENON, D ;
PICKARD, JD .
JOURNAL OF NEUROSURGERY, 1995, 82 (05) :756-763
[6]   Near-infrared monitoring of cerebral oxygenation state during carotid endarterectomy [J].
Kuroda, S ;
Houkin, K ;
Abe, H ;
Hoshi, Y ;
Tamura, M .
SURGICAL NEUROLOGY, 1996, 45 (05) :450-458
[7]   MONITORING ELECTROPHYSIOLOGIC FUNCTION DURING CAROTID ENDARTERECTOMY - A COMPARISON OF SOMATOSENSORY EVOKED-POTENTIALS AND CONVENTIONAL ELECTROENCEPHALOGRAM [J].
LAM, AM ;
MANNINEN, PH ;
FERGUSON, GG ;
NANTAU, W .
ANESTHESIOLOGY, 1991, 75 (01) :15-21
[8]   Internal and external carotid contributions to near-infrared spectroscopy during carotid endarterectomy [J].
Lam, JMK ;
Smielewski, P ;
AlRawi, P ;
Griffiths, P ;
Pickard, JD ;
Kirkpatrick, PJ .
STROKE, 1997, 28 (05) :906-911
[9]   NEAR-INFRARED MEASUREMENT OF CEREBRAL OXYGENATION - CORRELATION WITH ELECTROENCEPHALOGRAPHIC ISCHEMIA DURING VENTRICULAR-FIBRILLATION [J].
LEVY, WJ ;
LEVIN, S ;
CHANCE, B .
ANESTHESIOLOGY, 1995, 83 (04) :738-746
[10]  
MOORTHY SS, 1982, ANESTH ANALG, V61, P879