The thermoluminescence dose-response and other characteristics of the high-temperature TL in LiF:Mg,Ti (TLD-100)

被引:41
作者
Horowitz, Y. S. [1 ]
Oster, L. [2 ]
Datz, H.
机构
[1] Ben Gurion Univ Negev, Dept Phys, IL-84105 Beer Sheva, Israel
[2] Sami Shamoon Cool Engn, Phys Unit, Beer Sheva, Israel
关键词
TRACK-INTERACTION-MODEL; GLOW CURVE; HEATING RATE; THERMO-LUMINESCENCE; EMISSION-SPECTRA; LIF-TLD; DOSIMETRY; PEAKS; NEUTRON; SPACE;
D O I
10.1093/rpd/ncm241
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Various characteristics of the high-temperature thermoluminescence (HTTL) in the glow curve of LiF:Mg,Ti (TLD-100) are reviewed. The proposed applications of the HTTL to mixed-field radiation dosimetry are outlined with special emphasis on the question of the linearity/supralinearity of the HTTL dose-response at low dose levels from 2.5 to 250 mGy. Recent measurements of the HTTL dose-response using non-linear hot-gas heating and linear planchet heating are discussed in detail. It appears that a mild HTTL supralinearity of similar to 15-50% for each dose decade may be present, followed by an abrupt and rapid increase in the supralinearity > 250 mGy. However, difficulty in the estimation of background and the great variability in the protocols of measurement do not allow a definitive conclusion. There is much work to be done in the areas of protocol standardisation, materials selection, methods of data analysis and especially the details of background behaviour, and subtraction before the HTTL can become a reliable dosimetric tool.
引用
收藏
页码:191 / 205
页数:15
相关论文
共 51 条
  • [1] FURTHER CONSIDERATION OF TRACK-INTERACTION MODEL FOR THERMOLUMINESCENCE IN LIF(TLD-100)
    ATTIX, FH
    [J]. JOURNAL OF APPLIED PHYSICS, 1975, 46 (01) : 81 - 88
  • [2] FIGURE-OF-MERIT (FOM), AN IMPROVED CRITERION OVER NORMALIZED CHI-SQUARED TEST FOR ASSESSING GOODNESS-OF-FIT OF GAMMA-RAY SPECTRAL PEAKS
    BALIAN, HG
    EDDY, NW
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1977, 145 (02): : 389 - 395
  • [3] Investigation of the glow peak parameters, reusability and dosimetric precision of LiF:Mg,Cu,P at high heating rates up to 20 K.s-1
    Ben-Amar, G
    Ben-Shachar, B
    Oster, L
    Horowitz, Y
    Horowitz, A
    [J]. RADIATION PROTECTION DOSIMETRY, 1999, 84 (1-4) : 235 - 238
  • [4] Modelling the dose response of peaks 4, 5 and 5b, in TLD-100, as a function of recombination temperature
    Biderman, S.
    Oster, L.
    Horowitz, Y. S.
    [J]. RADIATION PROTECTION DOSIMETRY, 2006, 119 (1-4) : 285 - 288
  • [5] EFFECTS OF COOLING AND HEATING RATE ON TRAPPING PARAMETERS IN LIF-MG,TL CRYSTALS
    BOS, AJJ
    VIJVERBERG, RNM
    PITERS, TM
    MCKEEVER, SWS
    [J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1992, 25 (08) : 1249 - 1257
  • [6] BOS AJJ, 1993, 13193005 IRICIEMAT
  • [7] TL dosimetry of radon by the two peaks method
    Chernov, V
    Mironenko, S
    Minaev, E
    Alekseev, I
    [J]. RADIATION PROTECTION DOSIMETRY, 1999, 85 (1-4) : 329 - 332
  • [8] LIF DOSIMETRY .2. EFFECTS OF MG AND TI ON THERMOLUMINESCENT EMISSION-SPECTRA OF LIF
    CRITTENDEN, GC
    TOWNSEND, PD
    GILKES, J
    WINTERSGILL, MC
    [J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1974, 7 (17) : 2410 - 2421
  • [9] GERMAN U, 2007, COMMUNICATION
  • [10] GORBICS SG, 1969, P 2 INT C LUM DOS GA, P587