Estimation of the QT-RR relation: trade-off between goodness-of-fit and extrapolation accuracy

被引:5
作者
Vinet, Alain [1 ,2 ,3 ]
Dube, Bruno [2 ]
Nadeau, Reginald [2 ]
Mahiddine, Omar [2 ]
Jacquemet, Vincent [1 ,2 ,3 ]
机构
[1] Univ Montreal, Dept Physiol & Pharmacol, Fac Med, Montreal, PQ, Canada
[2] Hop Sacre Coeur, Ctr Rech, 5400 Boul Gouin Ouest, Montreal, PQ H4J 1C5, Canada
[3] Univ Montreal, Inst Genie Biomed, Montreal, PQ, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
QT interval; QT correction; QT-RR relation; hysteresis reduction; HEART-RATE; ATRIAL-FIBRILLATION; HOLTER RECORDINGS; QT/RR HYSTERESIS; INTERVAL; REPOLARIZATION; FORMULAS;
D O I
10.1088/1361-6579/aa57b4
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Correction of the QT interval in the ECG for changes in heart rate (RR interval) is needed to compare groups of patients and assess the risk of sudden cardiac death. The QTc represents the QT interval at 60 bpm, although most patients typically have a faster heart rate, thus requiring extrapolation of the QT-RR relationship. Objective: This paper investigates the ability of QT-RR models with increasing number of parameters to fit beat-to-beat variations in the QT interval and provide a reliable estimate of the QTc. Approach: One-, two- and three-parameter functions generalising the Bazett and Fridericia formulas were used in combination with hysteresis reduction (memory) obtained by time-averaging the history of RR intervals with exponentially-decaying weights. In normal men and women datasets of Holter recordings in normal subjects (24 h monitoring), two measures were computed for each model: the root mean square error (RMSE) of fitting and the difference between the estimated QTc and a reference QTc obtained by collecting data points around RR = 1000 ms. Main results: The two-and three-parameter functions all gave similar low RMSE with uncorrelated residues. An optimal memory parameter was found that still minimized the RMSE and could be used for all functions and subjects. This reduction in RMSE resulted from changes in the parameters linked to the increased steepness of the QT-RR relation after hysteresis reduction. At optimal memory, the two and three-parameter models provided poorer prediction of the QTc as compared to the Fridericia's model in subjects with fast heart rates, since accurate representation of the steeper QT-RR relation worsened the extrapolation that was then needed to determine the QTc. Significance: As a result, among all models investigated, the Fridericia formulation offered the best trade-off for QTc prediction robust to memory and fast heart rates.
引用
收藏
页码:397 / 419
页数:23
相关论文
共 24 条
[1]   Estimation and Modeling of QT-Interval Adaptation to Heart Rate Changes [J].
Cabasson, Aline ;
Meste, Olivier ;
Vesin, Jean-Marc .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2012, 59 (04) :956-965
[2]   PC-BASED ST-SEGMENT MONITORING WITH THE VCG [J].
DUBE, B ;
LEBLANC, AR ;
DUTOY, JL ;
DEROME, D ;
CARDINAL, R .
PROCEEDINGS OF THE ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, PTS 1-4, 1988, :1768-1770
[3]   RELATION BETWEEN QT AND RR INTERVALS DURING EXERCISE TESTING IN ATRIAL-FIBRILLATION [J].
EHLERT, FA ;
GOLDBERGER, JJ ;
ROSENTHAL, JE ;
KADISH, AH .
AMERICAN JOURNAL OF CARDIOLOGY, 1992, 70 (03) :332-338
[4]  
Elandt-Johnson R.C., 1980, SURVIVAL MODELS DATA
[5]   ELECTRICAL AND MECHANICAL RESTITUTION OF THE HUMAN-HEART AT DIFFERENT RATES OF STIMULATION [J].
FRANZ, MR ;
SCHAEFER, J ;
SCHOTTLER, M ;
SEED, WA ;
NOBLE, MIM .
CIRCULATION RESEARCH, 1983, 53 (06) :815-822
[6]   Use of a novel transfer function to reduce repolarization interval hysteresis [J].
Halamek, Josef ;
Jurak, Pavel ;
Bunch, T. Jared ;
Lipoldova, Jolana ;
Novak, Miroslav ;
Vondra, Vlastimil ;
Leinveber, Pavel ;
Plachy, Martin ;
Kara, Tomas ;
Villa, Marco ;
Frana, Petr ;
Soucek, Miroslav ;
Somers, Virend K. ;
Asirvatham, Samuel J. .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2010, 29 (01) :23-32
[7]  
Hofman N, 2007, EUR HEART J, V28, P575, DOI 10.1093/eurheartj/ehl355
[8]   Drug induced QT prolongation: the measurement and assessment of the QT interval in clinical practice [J].
Isbister, Geoffrey K. ;
Page, Colin B. .
BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 2013, 76 (01) :48-57
[9]   QT interval measurement and correction in patients with atrial flutter: a pilot study [J].
Jacquemet, V. ;
Gonzalez, R. Cassani ;
Sturmer, M. ;
Dube, B. ;
Sharestan, J. ;
Vinet, A. ;
Mahiddine, O. ;
LeBlanc, A. R. ;
Becker, G. ;
Kus, T. ;
Nadeau, R. .
JOURNAL OF ELECTROCARDIOLOGY, 2014, 47 (02) :228-235
[10]   Evaluation of a subject-specific transfer-function-based nonlinear QT interval rate-correction method [J].
Jacquemet, Vincent ;
Dube, Bruno ;
Knight, Robin ;
Nadeau, Reginald ;
LeBlanc, A. Robert ;
Sturmer, Marcio ;
Becker, Giuliano ;
Vinet, Alain ;
Kus, Teresa .
PHYSIOLOGICAL MEASUREMENT, 2011, 32 (06) :619-635