Reliability of stabilised commercial dynamometers for measuring hip abduction strength: a pilot study

被引:46
作者
Fenter, PC [1 ]
Bellew, JW [1 ]
Pitts, TA [1 ]
Kay, RE [1 ]
机构
[1] Louisiana State Univ, Hlth Sci Ctr, Sch Allied Hlth, Dept Phys Therapy, Shreveport, LA 71130 USA
关键词
D O I
10.1136/bjsm.37.4.331
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Background: Reliable quantification of hip abductor strength in a clinical setting is challenging. Objectives: To examine the intrarater and interrater reliability of three commonly used commercial dynamometers in the measurement of hip abduction. Methods: Supine gravity minimised measures of unilateral hip abduction strength were recorded in 10 women (mean (SD) age 23.5 (1.9) years) using three different commercially available dynameters. Measurements were repeated over a three day period with a different device used on each day. Results: Intrarater reliability ranged from 0.880 to 0.958 across the three devices, and measures of interrater reliability ranged from 0.899 to 0.948. Conclusion: Commercially available dynamometers can be used to quantify hip abduction strength with good to excellent reliability. A previously undescribed method of quantifying hip abduction strength in a clinical setting using readily available instrumentation is presented.
引用
收藏
页码:331 / 334
页数:4
相关论文
共 19 条
[1]  
AGRE JC, 1987, ARCH PHYS MED REHAB, V68, P454
[2]   Normative values for isometric muscle force measurements obtained with hand-held dynamometers [J].
Andrews, AW ;
Thomas, MW ;
Bohannon, RW .
PHYSICAL THERAPY, 1996, 76 (03) :248-259
[3]  
[Anonymous], ISSUES AGING
[4]  
[Anonymous], 2000, Foundations of clinical research: applications to practice
[5]  
BEASLEY W C, 1956, Phys Ther Rev, V36, P21
[6]  
BLESH TE, 1990, ELEMENTS RES PHYSICA
[7]   Reference values for extremity muscle strength obtained by hand-held dynamometry from adults aged 20 to 79 years [J].
Bohannon, RW .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1997, 78 (01) :26-32
[8]   INTERRATER RELIABILITY OF HAND-HELD DYNAMOMETRY [J].
BOHANNON, RW ;
ANDREWS, AW .
PHYSICAL THERAPY, 1987, 67 (06) :931-933
[9]   TEST-RETEST RELIABILITY OF HAND-HELD DYNAMOMETRY DURING A SINGLE SESSION OF STRENGTH ASSESSMENT [J].
BOHANNON, RW .
PHYSICAL THERAPY, 1986, 66 (02) :206-209
[10]   CLINICAL RELIABILITY OF MANUAL MUSCLE TESTING - MIDDLE TRAPEZIUS AND GLUTEUS MEDIUS MUSCLES [J].
FRESE, E ;
BROWN, M ;
NORTON, BJ .
PHYSICAL THERAPY, 1987, 67 (07) :1072-1076