Reliability of stabilised commercial dynamometers for measuring hip abduction strength: a pilot study

被引:45
作者
Fenter, PC [1 ]
Bellew, JW [1 ]
Pitts, TA [1 ]
Kay, RE [1 ]
机构
[1] Louisiana State Univ, Hlth Sci Ctr, Sch Allied Hlth, Dept Phys Therapy, Shreveport, LA 71130 USA
关键词
D O I
10.1136/bjsm.37.4.331
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Background: Reliable quantification of hip abductor strength in a clinical setting is challenging. Objectives: To examine the intrarater and interrater reliability of three commonly used commercial dynamometers in the measurement of hip abduction. Methods: Supine gravity minimised measures of unilateral hip abduction strength were recorded in 10 women (mean (SD) age 23.5 (1.9) years) using three different commercially available dynameters. Measurements were repeated over a three day period with a different device used on each day. Results: Intrarater reliability ranged from 0.880 to 0.958 across the three devices, and measures of interrater reliability ranged from 0.899 to 0.948. Conclusion: Commercially available dynamometers can be used to quantify hip abduction strength with good to excellent reliability. A previously undescribed method of quantifying hip abduction strength in a clinical setting using readily available instrumentation is presented.
引用
收藏
页码:331 / 334
页数:4
相关论文
共 19 条
  • [1] AGRE JC, 1987, ARCH PHYS MED REHAB, V68, P454
  • [2] Normative values for isometric muscle force measurements obtained with hand-held dynamometers
    Andrews, AW
    Thomas, MW
    Bohannon, RW
    [J]. PHYSICAL THERAPY, 1996, 76 (03): : 248 - 259
  • [3] [Anonymous], ISSUES AGING
  • [4] [Anonymous], 2000, Foundations of clinical research: applications to practice
  • [5] BEASLEY W C, 1956, Phys Ther Rev, V36, P21
  • [6] BLESH TE, 1990, ELEMENTS RES PHYSICA
  • [7] Reference values for extremity muscle strength obtained by hand-held dynamometry from adults aged 20 to 79 years
    Bohannon, RW
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1997, 78 (01): : 26 - 32
  • [8] INTERRATER RELIABILITY OF HAND-HELD DYNAMOMETRY
    BOHANNON, RW
    ANDREWS, AW
    [J]. PHYSICAL THERAPY, 1987, 67 (06): : 931 - 933
  • [9] TEST-RETEST RELIABILITY OF HAND-HELD DYNAMOMETRY DURING A SINGLE SESSION OF STRENGTH ASSESSMENT
    BOHANNON, RW
    [J]. PHYSICAL THERAPY, 1986, 66 (02): : 206 - 209
  • [10] CLINICAL RELIABILITY OF MANUAL MUSCLE TESTING - MIDDLE TRAPEZIUS AND GLUTEUS MEDIUS MUSCLES
    FRESE, E
    BROWN, M
    NORTON, BJ
    [J]. PHYSICAL THERAPY, 1987, 67 (07): : 1072 - 1076